—14— PERFORMANCE DATA (cont) STANDARD INDOOR PSC MOTOR COOLING CAPACITIES (cont) 583B048 COOLING PERFORMANCE TABLE Temp (F) Outdoor Air Entering Condenser Evaporator Air — CFM/BF 1200 / 0.06 1600 / 0.08 2000 / 0.11 Evaporator Air — Ewb (F) 62 67 72 62 67 72 62 67 72 75 TC SHC kW 47.9 41.5 3.38 52.3 34.8 3.43 56.8 28.2 3.48 49.6 47.4 3.68 53.7 38.7 3.78 58.1 29.9 3.82 50.5 50.5 4.01 54.0 41.6 4.23 57.7 30.7 4.27 85 TC SHC kW 45.7 40.4 3.77 50.2 34.1 3.80 54.7 27.4 3.86 47.5 46.5 4.03 51.6 37.9 4.

heruntergeladen wurde: 3   Dateigröße: 1 mb   Hersteller: Bryant  
Kategorie: Ventilatoren
@name

Only trained and qualified service personnel should install or service air conditioning equipment. Untrained personnel can perform basic maintenance, such as cleaning and replacing filters. All other operations should be performed by trained service personnel. When working on air conditioning equipment, observe precautions in literature, tags, and labels attached to unit. Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloth for brazing operations. Have fire extingu

heruntergeladen wurde: 0   Dateigröße: 2 mb   Hersteller: Bryant  
Kategorie: Ventilatoren
@name

Installation of this product should follow all manufacturer’s refrigerant charging and air flow instructions. Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life. 558J558J TABLE OF CONTENTS PAGE PAGE FEATURES AND BENEFITS .................... 3 MODEL NUMBER NOMENCLATURE ............ 4 FACTORY OPTIONS & ACCESSORIES ........... 5 ARI CAPACITY RATING ....................... 8 SOUNDPERFORMANCE ...................... 10 PHYSICALDATA ..................

heruntergeladen wurde: 0   Dateigröße: 343 kb   Hersteller: Bryant  
Kategorie: Ventilatoren
@name

FRESH AIR FROM HRV TO HOUSE 2. FRESH AIR FROM OUTSIDE TO HRV 3. STALE AIR FROM HOUSE TO HRV 4. STALE AIR FROM HRV TO OUTSIDE A05228 ABCDModelin.mmin.mmin.mmin.mmHRVBBLHA115017-1/4438.210-1/2266.74-1/2114.311279.4HRVBBLHA125017-1/4438.210-1/2266.74-1/2114.311279.4EFGModelin.mmin.mmin.mmHRVBBLHA11507-3/4196.94-3/8111.17-3/4196.9HRVBBLHA12507-3/4196.95-13/16147.67-3/4196.9Fig.1--HRVBBLHAUnitDimensions 5 A05426 Fig. 2 - --HRVBBSHA Unit Dimensions HRV A05425 Fig. 3 - -- HRVBBSVA Unit Dimensions Physi

heruntergeladen wurde: 34   Dateigröße: 343 kb   Hersteller: Bryant  
Kategorie: Ventilatoren
@name

A filter installed on the incoming outdoor air stream removes large airborne particles from the intake air stream before they enter the heat exchanger and reduces the maintenance required. The units’ acoustically engineered design makes the Bryant HRV the quietest on the market and ensures that comfort is felt, not heard. Unlatching two (2) suitcase style latches allows easy removal of the filters and core for cleaning. NOTE: The HRV should not be installed in an attic or unconditioned space unl

heruntergeladen wurde: 5   Dateigröße: 343 kb   Hersteller: Bryant  
Kategorie: Ventilatoren
@name

Setting the wall control to low will activate the continuous mode. OneTouch Control: Allows control of ventilator with the touch of a button. This control will operate as a main wall control. The OneTouch will operate the unit in Intermittent Mode (20 minutes per hour), continuous low speed, continuous high speed, and off. Automatic Defrost Cycle Features All models offer a non- --electric defrost cycle feature which prevents frost and ice buildup within the heat recovery core. When the outside

heruntergeladen wurde: 2   Dateigröße: 463 kb   Hersteller: Bryant  
Kategorie: Ventilatoren
@name

0---12---34---5<15003045601501---30004560753001---45006075904501---600075901056001---750090105120 FLOORAREA(m2) BEDROOMS0---12---34---56---7>7<1391421283542139.1---2792128354250279.1---4182835425057418.1---5573542505764557.1---697425057 ERV/ HRV HEATING LOAD BTUH OutsideTemp°FHeatingLoad(Btuh)@ InsideDesignTemp72°FERV1150ERV1200HRV1150HRV1250–2551868143663610603–2049197723629410057–155075796759529510–104783750956108964–54491705152688417042006594492578715423466474583732410391861514241677715395862

heruntergeladen wurde: 6   Dateigröße: 463 kb   Hersteller: Bryant  
Kategorie: Ventilatoren
@name

As temperatures drop below 23_F(- --5_C), indoor air is recirculated periodically through the heat exchanger core to prevent frost from forming. Competitors’ methods of supplementary electric defrost waste energy. Unlike rotary wheel heat exchangers which mix air streams, these cross- --flow or counterflow heat exchangers ensure that there is no mixing of the stale air stream with the fresh outdoor air stream. A filter installed on the incoming outdoor air stream removes large airborne particles

heruntergeladen wurde: 7   Dateigröße: 1 mb   Hersteller: Bryant  
Kategorie: Ventilatoren
@name

Clean-as necessary. 4. Inspect electrical connections for tightness and controls for proper Operation each heating and cooling season. Service as neccssary. A WARNING: As with any mechanical equipment, personal injury can result from sharp metal edges. Be careful when removing parts. A. Air Filter To clean or replace air filter, grasp it at bottom and lift it out of unit. Clean filter using cold water. Rinse clean and let dry. Oiling or coating of filter is not required. To replace, stand f

heruntergeladen wurde: 1   Dateigröße: 1 mb   Hersteller: Bryant  
Kategorie: Ventilatoren
@name

Pay particular attention to high- and low-voltage wiring of sequencers. 2. Check plug wiring to mdee sure that it is wired correctly, 3. Check voltage to sequencer. Sequencer number 1 receives a 24-vac signal. If it is receiving correct voltage, check to see if sequencer is closing. If sequencer is not closing but is -10- '14/2008/THU 03:47 UTC TECH PUB FAX No. 317 240 5662 P. 01 TABLE 3—MALE/FEMALE QUICK-CONNECT TERMINALS SIZE FEMALE SIZE MALE DESCRIPTION 0.250 X 0.032 М2 Motor line v