Login:
Stimmen - 2, Durchschnittliche Bewertung: 3.5 ( )

Anleitung NuTone, modell KD 6500.1

Hersteller: NuTone
Dateigröße: 728.26 kb
Dateiname: KD6500-1E-UL_KD9500-1_UandC_Guide.pdf
Unterrichtssprache:enfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Suitable to deal with maximum vapour emission, this turns off automatically ten minutes after starting operation. It can be disabled by pressing the button T5. Press T5 for approximately 3 seconds to enable the Power function (maximum suction power), which is indicated by flashing of the LED over the button. This function will be revert to intensive speed after 5 minutes or when T5 is pressed again. MAINTENANCE 0 aaaaaaaaaaaaaaaaaaaaaaa0 aaaaaaaaaaaaaaaaaaaaa0 Constant maintenance guarantees proper operation and longterm reliability. Particular attention should be paid to the metal grease filters and, for recirculation hoods only, to the activated charcoal filters. The appliance is equipped with a system that indicates automatically when it is time to carry out maintenance operations. Metal grease filters • Cleaning These filters must be washed when LED Filters starts, or at the most once every 2 months, using a normal household detergent; their compact size also enables them to be washed in a dishwasher. • Removing the filters Remove one filter at a time, pulling and turning the handle in an anticlockwise direction – see fig.10. Replace by repeating the same operations in reverse order, making sure that the handle is turned to face the outside. • Enabling the alarm signal The hood is already set up to trigger an alarm indicating saturation of the metal grease filters, so this function does not need to be enabled. • Resetting the alarm signal To turn the alarm signal off, proceed as follows: -Turn off the lights and the suction motor; -Press the T4 button for at least 3 seconds, until the LEDs flash in confirmation. In any case the saturated filters alarm will only come into operation when the suction motor is turned on. WARNING: always comply with the maintenance and replacement times indicated, in order to avoid a possible risk of fire when the filters are saturated with grease. GB 0 0 0 0 0 0 0 0 0 0 aaaaaaaaaaaaaaaaaaaaaaaaaaaa0 9 aaaaaaaaaaaaaaaaaaaaaaaa0 aaaaaaaaaaaaaaaaaaaaa0 Active carbon filter • Operation The activated charcoal filter is only fitted in recirculation type hoods. It will retain odours until it becomes saturated. It cannot be washed or regenerated, and must be replaced when the Filters LED starts, or at least once every 4 months of use. Attention:in recirculation type hoods the T2 Motor LED may start to flash as well as the Speed + T4 LED. This indicates that as well as replacing the activated charcoal filter, it is also necessary to perform maintenance operations on the metal grease filters. • Replacing Remove the grease filters (fig.10) and take out the activated charcoal filter from its housing, turning the lugs provided (fig. 11). Insert the new activated charcoal filter and replace the metal grease filters. • Enabling the alarm signal In recirculation type hoods the saturated filters alarm must be enabled as indicated below: - Turn off the lights and the suction motor; -Press and hold the T4 button for at least 10 seconds, until the LEDs start to flash. Note the number of flashes: -2 flashes of the LED Activated charcoal filter saturation alarm ENABLED. -1 flash of the LED Activated charcoal filter saturation alarm DISABLED; • Resetting the alarm signal To turn the alarm signal off, proceed as follows: -Press the T4 button for at least 3 seconds, until the LEDs flash in confirmation. In any case the saturated filters alarm will only come into operation when the suction motor is turned on. WARNING: always comply with the maintenance and replacement times indicated, in order to avoid a possible risk of fire when the filters are saturated with grease. Lighting • Before attemping to replace the lamps, make sure that the light switch is turned off. • It consists of 2 20 W-halogen spotlights (60 cm model) and 3 20 W-halogen spotlights (90 cm model). • Replacement (fig.12) Remove the two screws that lock the metal ring, take the spotlight out of its holder by pulling slightly. When replacing, make sure that both pins are well inserted in the holder seat. Cleaning When cleaning the hood: - Never use a wet cloth or sponge, or running water. - Never use thinners or products containing alcohol, as they might damage the paintwork. -Never use abrasive cleaning materials, in particular when cleaning stainless steel surfaces. It is recommended to use a damp cloth and mild liquid household cleaner. 10 0 0 0 0 0 0 0 0 0 0 aaaaaaaaaaaaaaaaaaaaaaaaaaaa0 GB aaaaaaaaaaaaaaaaaaaaaaaa0 aaaaaaaaaaaaaaaaaaaaa0 LISEZ BIEN CETTE FICHE AVANT D’INSTALLER LA HOTTE AVERTISSEMENT -POUR MINIMISER LE RISQUE D’UN FEU DE GRAISSE SUR LA TABLE DE CUISSON : Ne jamais laisser un element de la table de cuisson fonctionner sans sur-veillance a la puissance de chauffage maximale; un renversement/deborde-ment de matiere graisseuse pourrait provoquer une inflammation et le generation de fumee. Utiliser toujours une puissance de chauffage moyenne ou basse pour le chauffage d’huile. Veiller a toujours faire fonctionner le ve...

Dieses Handbuch ist für folgende Modelle:
Ventilatoren - KD 6500.1 (728.26 kb)
Ventilatoren - KD 6500.1 (728.26 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien