Login:
Stimmen - 5, Durchschnittliche Bewertung: 4 ( )

Anleitung GBC, modell QUANTUM P70IX

Hersteller: GBC
Dateigröße: 475.89 kb
Dateiname: GBC-Quantum-P70iX-Users-Manual.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Introduction Introduction 1-1 2. Getting to Know your Quantum P70iX Operating Controls 2-1 Plastic Covers 2-2 3. Operation Operating Controls 3-1 4. Options and Accessories Die Set 4-1 Die Set Storage 4-2 5. Home Screen Operation 5-1 Service 5-1 6. Maintenance Problem solving 6-1 Paper Jam 6-2 7. Specifications Specifications Quantum P70iX 7-1 Power Cord Specifications 7-2 Safety Information SAFETY MESSAGES The safety of you and others is very important to GBC. Important safety messages and information are contained within this manual as well as on the machine itself. Please be certain to carefully read and understand all of these before operating the machine. ! The safety alert symbol precedes each safety message in this Operating Instruction Manual. This symbol indicates a potential personal safety hazard that could hurt you or others, as well as cause product or property damage. The following pictorial is found on the Quantum P70iX: ! ! crushed or cut. i Safety Information SAFETY MESSAGES continued ! WARNING: This means you can be seriously injured by crushing and cutting, moving parts. Do not operate without guards in place. Do not attempt to defeat any of the safety interlock switches. The following symbols appear on this product, and their meaning is as follows: I Means the electrical power is “ON”. O Means the electrical power is “OFF”. IMPORTANT SAFEGUARDS • Use the Quantum P70iX only for its intended purpose of punching paper and covers according to the indicated specifications. • Retain this Operating Instructions manual for later use. ! CAUTION: IN CASE OF EMERGENCY, USE THE POWER CORD AS A MAIN DISCONNECT. ii Safety Information IMPORTANT SAFEGUARDS continued • The Quantum P70iX must be connected to a supply voltage corresponding to the electrical rating of the machine operating instructions (also listed on the serial number label). • The socket-outlet shall be located near the equipment and shall be easily accessible. • The grounding plug is a safety feature and will only fit into the proper grounding- type power outlet. If you are unable to insert the plug into an outlet, contact a qualified electrician to have a suitable outlet installed. Do not alter the plug on the end of the cordset (if provided) of the Quantum P70iX. It was provided for your safety. • Unplug the Quantum P70iX before moving the machine or whenever the machine is not in use for an extended period of time. • Do not operate the Quantum P70iX if the machine has a damaged power supply cord or plug. Do not operate the machine after any malfunction, if liquid has been spilled into the machine, or it the machine has been damaged in any way. • Do not overload electrical outlets beyond their capacity. To do so can result in fire or electrical shock. • Do not attempt to bypass the safety interlocks, if you do so you may be injured SERVICE Do not attempt to service your Quantum P70iX yourself. Contact an authorized GBC service representative for any required repairs or major maintenance for your Quantum P70iX. There are NO user-serviceable parts inside the machine. To avoid potential personal injury and/or property or machine damage. ! DO NOT REMOVE THE MACHINE’S SIDE COVERS AND TOP COVERS. CLEANING You may clean the exterior of the Quantum P70iX using a soft, damp cloth. Do not use detergent or solvents as damage to the machine may occur. iii Safety Information MAIN CORDSET SELECTION (THE FOLLOWING NOTE APPLIES ONLY TO EUROPEAN UNITS) CAUTION: WHEN CHOOSING A DETACHABLE LINE CORD FOR USE WITH YOUR Quantum P70iX, ALWAYS OBSERVE THE FOLLOWING ! PRECAUTIONS The cordset consist of three parts; the attachment plug, cordage and appliance inlet. Each of these components must have European regulatory approvals for safety. The following minimum electrical ratings for the specific cordset are published for safety purposes. DO NOT USE CORDSETS THAT DO NOT MEET THE FOLLOWING MINIMUM ELECTRICAL REQUIREMENTS. PLUG: 3 amperes, 250 volts, 50/60 Hz, Class 1, 3 conductor, European safety approved. CORDAGE: Type H05VV-F3G0.75, Harmonized ( < HAR> ). The “< >” symbols indicate cordage approved to appropriate European standard (NOTE: “HAR” may be substituted for approval mark of European safety agency, which approved the cordage. An example would be “ < VDE > “). APPLIANCE CONNECTOR: 3 ampere, 250 volts, 50/60 Hz, European safety approved, Type IEC 320. The cordset shall not exceed 3 meters in length. A cordset with component electrical ratings greater than the minimum specified electrical ratings may be substituted. iv Safety Information MAIN CORDSET SELECTION continued (THE FOLLOWING NOTE APPLIES ONLY TO THE U.S. UNITS.) FCC NOTE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiat...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien