Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Southbend, modell HEAVY DUTY COUNTERLINE HDG-36

Hersteller: Southbend
Dateigröße: 533.21 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


A kit for conversion to a different type of gas may be purchased from Southbend (see page 22 for conversion instructions). This appliance should be connected ONLY to the type of gas for which it is configured. An adequate gas supply is imperative. Undersized or low pressure lines will restrict the volume of gas required for satisfactory performance. Fluctuations of more than 25% on natural gas or 10% on propane gas will create problems and affect burner operating characteristics. A 1/8" pressure tap is located on the manifold to measure the manifold pressure. An adequate gas supply line to the unit should be no smaller than the inside diameter of the pipe from the unit to which it is connected. Purge the supply line to clean out dust, dirt, or other foreign matter before connecting the line to the unit. All pipe joints and connections must be tested thoroughly for gas leaks. Use only soapy water for testing on all gases. NEVER use an open flame to check for gas leaks. All connections must be checked for leaks after the unit has been put into operation. Test pressure should not exceed 14" W.C. ! CAUTION THIS APPLIANCE AND ITS INDIVIDUAL SHUTOFF VALVE MUST BE DISCONNECTED FROM THE GAS SUPPLY PIPING SYSTEM DURING ANY PRESSURE TESTING OF THAT SYSTEM AT TEST PRESSURES IN EXCESS OF 1/2 PSIG (3.45 kPa). THIS APPLIANCE MUST BE ISOLATED FROM THE GAS SUPPLY PIPING SYSTEM BY CLOSING ITS INDIVIDUAL MANUAL SHUTOFF VALVE DURING ANY PRESSURE TESTING OF THE GAS SUPPLY PIPING SYSTEM AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSIG (3.45 kPa). CLEARANCES ! WARNING There must be adequate clearance between units and adjacent construction. Clearance must also be provided for servicing and for operation. Measure back clearance from rear of 2" stand-off brackets. Minimum Clearances from COMBUSTABLE construction: Griddle Models Open Top Models Sides 12" 10" Back 8" 7" Minimum Clearances from NON-COMBUSTABLE construction: Griddle Models Charbroiler Models Open Top Models Sides 0" 0" 0" Back 0" 0" 0" VENTILATION ! WARNING Improper ventilation can result in personal injury or death. Ventilation which fails to properly remove flue products can cause headaches, drowsiness, nausea, or could result in death. All units must be installed in such a manner that the flow of combustion and ventilation air are not obstructed. Provisions for adequate air supply must be provided. Do not obstruct the front of the unit at the top by the control panel as combustion air enters through these areas. NOTICE Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be covered by the warranty. Air for combustion enters the rear of the appliance. An exhaust flue runs along the top rear edge of griddle and charbroiler models. Southbend recommends that a ventilation canopy extend 6" past the edges of the appliance and be located 6'6" above the floor. If a wall exhaust fan is installed in the wall behind the appliance, it should be at least two feet above th...

Dieses Handbuch ist für folgende Modelle:
Andere Küchengeräte - HEAVY DUTY COUNTERLINE HDG-24 (533.21 kb)
Andere Küchengeräte - HEAVY DUTY COUNTERLINE HDG-24-M (533.21 kb)
Andere Küchengeräte - HEAVY DUTY COUNTERLINE HDG-36-M (533.21 kb)
Andere Küchengeräte - HEAVY DUTY COUNTERLINE HDG-36-RE (533.21 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien