Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.5 ( )

Anleitung Harbor Freight Tools, modell 95591

Hersteller: Harbor Freight Tools
Dateigröße: 997.36 kb
Dateiname: 95591.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Safety impact eye goggles are available from Harbor Freight Tools. Use the right product for the job. 3. There are certain applications for which this product was designed. Do not use small tools, attachments, or equipment to do the work of larger industrial tools, attachments, or equipment. Maintain a safe environment. 4. Keep the area well lit. Make sure there is adequate surrounding space. Always keep the area free of obstructions, grease, oil, trash, and other debris. Do not use an electrically powered product in areas near flammable chemicals, dusts, and vapors. 5. Risk of electrical shock. Always disconnect the Pump from its power source before handling or making any adjustments to the tool. Always wear non-skid rubber boots when water is on the floor and you must unplug the Pump. Make sure the electrical power source is a separately fused, grounded, 3-wire type GFCI (Ground Fault Circuit Interrupter) outlet. Do not remove the ground prong on the Power Cord Plug. Do not use an extension cord. Do not pump hazardous materials. 6. Do not pump explosive or flammable materials such as fuel, oil, kerosene, gasoline, etc. Do not pump in close proximity to flammable or explosive materials. Do not pump fats, oils, salt or waste water. This Pump is designed to move clean or dirty water only. Do not pump water hotter than 95 degrees Fahrenheit. Secure the discharge pipe 7. (not included) to a solid surface to ensure the stability of the Pump. Position the Pump on a flat, level, 8. solid surface. OUTLETDEVICECORDDrip Loop 9. Arrange a “drip loop” in the Power Cord connecting the Pump to a 115 volt, GFCI electrical outlet. A drip loop is that part of the Power Cord below the level of the outlet to prevent water from traveling along the Power Cord and coming in contact with the outlet. If the Power Plug or electrical outlet does get wet, do not unplug the Power Cord. Disconnect the fuse or circuit breaker that supplies power to the Pump. Then, unplug the Power Cord and examine for presence of water in the outlet. If necessary,10. have a certified electrician install (within 10 feet of where the Pump will be located) a 115 volt, GFCI electrical outlet that is dedicated only to the Pump. Any outlet should be above the water line. NEVER raise or lower the Pump by 11. its electrical Power Cord. In cold weather, when the Pump 12. is not in use, protect the interior of the Pump from freezing by draining the water and pumping a permanent type automobile anti- freeze containing a rust inhibitor through the system. A 50% mixture with water is recommended. Be sure to flush the system with a neutralizing liquid prior to re-use of the Pump. If an extension cord is used (for 13. temporary use only) connections must not come in contact with water or any wet surfaces. Prior to use, and periodically 14. thereafter, check to make sure all connections are tight and secure. Industrial applications must follow 15. OSHA requirements. People with pacemakers should 16. consult their physician(s) before use. Electromagnetic fields in close proximity to heart pacemaker could cause pacemaker interference or pacemaker failure. The warnings and cautions dis17. cussed in this manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator. Grounding To prevent electric shock and death from incorrect grounding wire connection: Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the power cord plug provided with the tool. Never remove the grounding prong from the plug. Do not use the tool if the power cord or plug is damaged. If damaged, have it repaired by a service facility before use. If the plug will not fit the outlet, have a proper outlet installed by a qualified electrician. Grounded Tools: Tools with Three Prong Plugs 3-Prong Plug and Outlet 1. Tools marked with “Grounding Required” have a three wire cord and three prong grounding plug. The plug must be connected to a properly grounded outlet. If the tool should electrically malfunction or break down, grounding provides a low resistance path to carry electricity away from the user, reducing the risk of electric shock. (See 3-Prong Plug and Outlet.) The grounding prong in the plug is 2. connected through the green wire inside the cord to the grounding system in the tool. The green wire in the cord must be the only wire connected to the tool’s grounding system and must never be attached to an electrically “live” terminal. (See 3-Prong Plug and Outlet.) The tool must be plugged into an 3. appropriate outlet, properly installed and grounded in accordance with all codes and ordinances. The plug and outlet should look like those in the preceding illustration. (See 3-Prong Plug and Outlet.) Double Insulated Tools: Tools with Two Prong Plugs Outlets for 2-Prong Plug ...

Dieses Handbuch ist für folgende Modelle:
Pumps - 95593 (997.36 kb)
Pumps - 95592 (997.36 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien