|
Anleitung Zusammenfassung
outdoors, make sure it is marked with the suffix “W-A” (“W” in Canada) to indicate it is acceptable for outdoor use. Make sure the extension cord is prop7. erly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified electrician before using it. Protect the extension cords from 8. sharp objects, excessive heat, and damp or wet areas. RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS* (120/240 VOLT) NAMEPLATE AMPERES (at full load) EXTENSION CORD LENGTH 25’ 50’ 75’ 100’ 150’ 0 – 2.0 18 18 18 18 16 2.1 – 3.4 18 18 18 16 14 3.5 – 5.0 18 18 16 14 12 5.1 – 7.0 18 16 14 12 12 7.1 – 12.0 18 14 12 10 - 12.1 – 16.0 14 12 10 - - 16.1 – 20.0 12 10 - - - TABLE A * Based on limiting the line voltage drop to five volts at 150% of the rated amperes. Symbology Double Insulated Canadian Standards Association Underwriters Laboratories, Inc. V~ Volts Alternating Current A Amperes n0 xxxx/min. No Load Revolutions per Minute (RPM) UNPACKING When unpacking, check to make sure all the parts shown on the Parts List on page 12 are included. If any parts are missing or broken, please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible. ASSEMBLY AND OPERATING INSTRUCTIONS Note: For additional information regarding the parts listed in the following pages, refer to the Assembly Diagram on page 13. WARNING! Always make sure to turn off the electricity powering the Pump’s electrical outlet and that the Pump is unplugged from its outlet prior to assembling the unit, unclogging the unit, or making any adjustments to the unit. If necessary,1. have a certified electrician install (within 10 feet of where the Pump will be located) a 115 volt, GFCI electrical outlet that is dedicated only to the Pump. Any outlet should be well above the water line. The discharge has both internal and external NPT threads. Use either 1-1/4” NPT 2. Male or 1-1/2” NPT Female PVC pipe for the discharge line. Do not use a pipe smaller than 1-1/4”. REV 08b TO 115 VOLT, GROUNDEDGFCI OUTLET1/8” AIR BLEED HOLEBASE(25) DISCHARGE PIPE(NOT INCLUDED) CHECK VALVEORUNION(NOT INCLUDED) FIGURE Eo1-1/4” OR 1-1/2” NPT PVC 3. Connect the Discharge Pipe to the Base (25). NOTE: Make sure the Discharge Pipe is secured to a solid surface, with appropriate hardware (not included), to ensure the stability of the Pump. (See Figure E.) Install an additional union (not included) or other means of separating the Dis4. charge Pipe just above the floor to facilitate removal of the Pump if necessary. (See Figure E.) A check valve (not included) is recommended just above, or in place of, the union 5. to prevent the backflow of water after each pump cycle. If a Check Valve is used, a 1/8” diameter air bleed hole should be drilled through the Discharge Pipe just above the lower Base (25) to prevent Pump “airlock”. A small spray of water out of this hole is normal while the Pump is running. (See Figure E.) Carefully set the Pump in place. 6. Do not lower or raise the Pump by the Power Cord or Discharge Pipe. (See Figure E.) The Float Switch (2) automatically switches on and off at a water depth of approxi7. mately 4 inches. The ON/OFF height can be manually changed by adjusting the Float Switch Lock. CAUTION: Do not run the Pump dry. Doing so will increase wear to the unit and possibly cause seal damage. (See Figure E.) Note: This Pump has a built-in thermal protector for the Motor which automatically shuts it off to avoid overheating. After the Motor cools, it will cycle back on. Wait for the cycle to continue. Do not try to turn on the Pump manually after it has automatically shut off. Connect additional Discharge Pipe as needed to direct the water discharge to 8. the desired location. The discharge should be kept as short as possible with a minimum number of turns. IMPORTANT: Do not exceed the maximum lift of the Pump: Model 95591 = 20 Feet. Model 95592 = 24 Feet. Model 95593 = 26 Feet. Connect the Power Cord & Plug to its 115 volt, GFCI electrical outlet, while making 9. sure to form a “drip loop” in the Power Cord. (See Drip Loop, page 5.) When the water level exceeds approximately 4 inches the Pump will automatically 10. turn on and run continuously until the water level falls below 4 inches at which time the Pump will automatically turn off. 11. WARNING! When shutting off power to the Pump, always shut off the electrical power to the GFCI outlet first. Then, disconnect the Pump’s Power Cord & Plug from the GFCI outlet. INSPECTION, MAINTENANCE, AND CLEANING WARNING! Always shut off the electrical power to the GFCI outlet first. Then, disconnect the Pump’s Power Cord & Plug from the GFCI outlet prior to performing any inspection, maintenance, or cleaning procedures. Before each use,1. inspect the general condition of the Pump. Check for cracked or broken parts, damaged electrical wiring, clogged Impeller Cover, Impeller, Discharge Pipes, and any other condition that may affect safe operation...
Dieses Handbuch ist für folgende Modelle:Pumps - 95591 (997.36 kb)
Pumps - 95592 (997.36 kb)