Anleitung Zusammenfassung


8. Wipe all warmer plates and the exterior of the brewer with a soft clean cloth or sponge moistened with clean water. 10. Reinstall the gasket INSIDE the brew head, then reinstall the spray disk. 11. Reinstall the brew chamber. 12. Decanters may be washed in a sink or dishwasher. Be sure decanters are well rinsed and dry before use. Procedure is complete CAUTION: Electric Shock Hazard Do not submerge or immerse brewer in water. Do not pour or splash water into or over air vents, control panel or warmer plates. IMPORTANT: DO NOT use steel wool, sharp objects, or caustic, abrasive or chlorinated cleansers to clean the brewer or decanters. 11 SERVICING INSTRUCTIONS — PLUMBING SERVICING INSTRUCTIONS — PLUMBING WATER TANK FUNCTION 1. Water enters at the inlet fitting of the fill solenoid (32). The solenoid admits water via a command from the controller. NOTE: The solenoid has an internal strainer. To clean the strainer: Shut off water supply. Unscrew the plastic cap protruding from the rear of the brewer. Remove the cap, inlet fitting and washer. With pliers, grasp the bar of the strainer and pull straight out. Wash any debris from the strainer. Note orientation - DO NOT reverse strainer. Reassemble and reinstall. Turn water supply back on. 2. Water enters the tank (2) thru the fill tube (16). Water is heated in the tank by the heating element (15). 3. The tank lid (9) is sealed around the edge with a gasket (6), and is secured by 3 clips (10). FILL PORT 4. Heated water is dispensed to the brew head through the VENT PORT brew tube (14), brew solenoid (18), and spout of the brew BREW PORT fitting (19). The brew solenoid is energized during the brew FAUCET PORT cycle by the controller. HEATER NOTE: The flow rate of the brew solenoid is factory set. PORTS DO NOT adjust. 5. Hot water is sprayed over the coffee grounds by the spray disc (24), which is sealed to the brew head by a gasket (23). 6. The tank is vented through the vent elbow fitting (40) and vent tubes (11 & 13). 7. Water for the hot water faucet (1) is supplied from the tank through the faucet supply tube (12). LID TANK GASKET CLIP LID GASKET SOLENOID STRAINER WASHER INLET FITTING CAP (note orientation DO NOT REVERSE) FILL SOLENOID FLOW CONTROL (installed) 12 SERVICING INSTRUCTIONS — PLUMBING (continued) 13 ITEM DESCRIPTION PART N0. USED ON 1 2 ASSEMBLY, WATER TANK (120V) 83500 2012, 2072 2015, 2075 6 GASKET, TANK LID 83499 ALL 9 TANK LID 83504 ALL 10 RETAINING CLIP, TANK LID 83506 ALL 11 HOSE, OVERFLOW (2 pc SILICONE 4.5” LONG) 86014 ALL 12 HOSE, FAUCET SUPPLY (SILICONE, 10” LONG) 83538 ALL 13 TUBE, VENT (METAL, 2.3” LONG) 83384 ALL 14 TUBE, BREW SUPPLY VENTED ASSEMBLY 16 TUBE, FILL (SILICONE, 83540 ALL 18 SOLENOID, BREW (DUMP) 83388 ALL 19 ELBOW, BREW 83152 ALL 23 GASKET, SPRAY HEAD 82215 ALL 24 SPRAY DISK 82727 ALL 32 SOLENOID, FILL 83612 ALL 40 ELBOW, VENT 8043-11 ALL 48 INSERT, SPRAY HEAD 83571 ALL FAUCET, HOT WATER 8783-1 ALL ASSEMBLY, WATER TANK (240V) 83753 2016, 2074 ASSEMBLY, WATER TANK (DUAL VOLTAGE) 84010 86013 ALL SERVICING INSTRUCTIONS — PLUMBING (continued) 13 ITEM DESCRIPTION PART N0. USED ON 1 2 ASSEMBLY, WATER TANK (120V) 83500 2012, 2072 2015, 2075 6 GASKET, TANK LID 83499 ALL 9 TANK LID 83504 ALL 10 RETAINING CLIP, TANK LID 83506 ALL 11 HOSE, OVERFLOW (2 pc SILICONE 4.5” LONG) 86014 ALL 12 HOSE, FAUCET SUPPLY (SILICONE, 10” LONG) 83538 ALL 13 TUBE, VENT (METAL, 2.3” LONG) 83384 ALL 14 TUBE, BREW SUPPLY VENTED ASSEMBLY 16 TUBE, FILL (SILICONE, 83540 ALL 18 SOLENOID, BREW (DUMP) 83388 ALL 19 ELBOW, BREW 83152 ALL 23 GASKET, SPRAY HEAD 82215 ALL 24 SPRAY DISK 82727 ALL 32 SOLENOID, FILL 83612 ALL 40 ELBOW, VENT 8043-11 ALL 48 INSERT, SPRAY HEAD 83571 ALL FAUCET, HOT WATER 8783-1 ALL ASSEMBLY, WATER TANK (240V) 83753 2016, 2074 ASSEMBLY, WATER TANK (DUAL VOLTAGE) 84010 86013 ALL SERVICING INSTRUCTIONS - ELECTRICAL FUNCTION 1. Pressing the POWER key energizes the unit. The POWER LED will glow whenever the unit is ON. 2. Automatic fill is accomplished via a FILL SOLENOID (32) and a WATER LEVEL PROBE (7). The probe senses ground through the water in the tank. When the water level falls below the probe and ground is no longer sensed, the CONTROLLER (20) energizes the fill solenoid (32) until the water level again reaches the water level probe. 3. Pressing the BREW key begins the brew cycle. Pressing the CANCEL key at any time during the brew cycle terminates the brew. The BREW SOLENOID (18) is energized by the CONTROLLER (20) for a time determined by the BREW TIME setting. A second brew can be started only after the brew time plus the DRIP OUT time has elapsed. 4. Brew water temperature is controlled via a WATER TEMPERATURE SENSOR (3) and a HEATING ELEMENT (15) controlled by a TRIAC (17) electronic switch. The element is energized according to the sensed water temperature and the BREW TEMP setting. An over-temperature condition will trip the HI-LIMIT THERMOSTAT (4), de-energizing the heating element. Note: On 120 volt units, hi-limit will au...

Dieses Handbuch ist für folgende Modelle:
Kaffeemaschinen - 2016EX (1.86 mb)
Kaffeemaschinen - 2074FRL (1.86 mb)
Kaffeemaschinen - 2074L (1.86 mb)
Kaffeemaschinen - 2016 (1.86 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien