|
Anleitung Zusammenfassung
Place one log (No. 9) at the LH rear resting on the base log, and one log (No. 8) at the RH rear. See diagram 32. AR1286 32 8. OXYGEN DEPLETION SENSOR 8.1 The appliance is fitted with an oxygen sensitive pilot system that will act to cut off the gas supply to the fire should the oxygen in the room fall below its normal level. If the fire is turned off by this device, it usually indicates that there is a problem with the flue system, and this should be inspected by a qualified engineer. Do not attempt to use the fire until an engineer says it is safe to do so. This device is not a substitute for an independently mounted carbon monoxide detector. 9. FLAME FAILURE DEVICE 9.1 This is a safety feature incorporated in all GAZCO fires which automatically switches off the gas supply if the pilot goes out and fails to heat the thermocouple. 10. RUNNING IN 10.1 The surface coating on the fuel effect used in your GAZCO fire will "burn off" during the first few hours of use producing a harmless and temporary odour. This will disappear after a short period of use. If the odour persists, ask your installer for advice. 11. SERVICING 11.1 The fire must be serviced every 12 months by a qualified Gas Engineer. In all correspondence always quote the appliance type and the serial number which may be found on the databadge, located on a chain underneath the control valve. 11 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION MODEL GASTYPE GASCATEGORY INLETPRESSURE(mb) AERATIONSIZE INJECTIONSIZE BURNERPRESSURE(mb) (pre-set) INPUT(kW) GAS FLOW RATE(m3/hr) HIGH LOW HIGH LOW HIGH LOW TAHOE NATURAL G20 20 mb 7.5mm 1100 9.0 2.6 12 6 1.11 0.56 BUTANE G30 29 mb 3 * 15mm 400 16.3 4.6 12 6 0.34 0.17 PROPANE G31 37 mb 3 * 15mm 400 21.1 6.0 12 6 0.43 0.22 SMALLASPEN &CHAMONIX NATURAL G20 20 mb 7.5 mm 1600 5.4 1.7 13 6.5 1.21 0.61 BUTANE G30 29 mb 3 * 15mm 400 20.0 5.6 13 6.5 0.36 0.18 PROPANE G31 37 mb 3 * 15mm 400 25.3 7.0 13 6.5 0.48 0.24 MEDIUM& LARGECHAMONIX& LARGEASPEN NATURAL G20 20 mb 7.5mm 1600 8.3 2.6 16 8 1.51 0.76 BUTANE G30 29 mb 3 *15mm 600 15.7 4.3 16 8 0.45 0.23 PROPANE G31 37 mb 3 * 15mm 600 20.5 5.6 16 8 0.58 0.29 12 INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 1. FLUE AND CHIMNEY REQUIREMENTS 1.1 The chimney or flue system must comply with the rules in force. 1.2 Fireplace opening up to 450mm (18") wide by 600mm (24") high will usually work with a 175mm (7") diameter flue. Larger openings will require bigger flues. See diagram 1 as a guide. A B C D 1 AR0595AR0596 A B D C mm A 350 mm B 550 cm2 A x B 1925cm2 3.0m 175 4.5m 175 C 6.0m 175 9.0m 175 15.0m 175 400 550 2200cm2 175 175 175 175 175 460 460 2116cm2 175 175 175 175 175 460 550 2530cm2 200 175 175 175 175 460 610 2806cm2 200 200 175 175 175 610 460 2806cm2 200 200 175 175 175 610 610 3721cm2 250 225 200 200 175 610 760 4636cm2 300 250 250 225 200 760 460 3496cm2 225 225 200 200 175 760 610 4636cm2 250 250 250 225 200 760 760 5776cm2 300 300 250 250 225 760 910 6916cm2 350 300 300 250 250 910 460 4186cm2 250 225 225 200 200 910 610 5551cm2 300 300 250 250 225 910 760 6916cm2 350 300 300 250 250 910 910 8281cm2 350 350 300 300 250 910 1070 9737cm2 -350 350 300 300 1070 460 4922cm2 300 250 250 225 200 1070 610 6527cm2 300 300 300 250 250 1070 760 8132cm2 350 350 300 300 250 1070 910 9737cm2 • 350 350 300 300 1070 1070 11449cm2 • • 350 350 300 1070 1220 13054cm2 • • • 350 350 1220 460 5612cm2 300 300 250 250 225 1220 610 7442cm2 350 300 300 300 250 1220 760 9272cm2 • 350 350 300 300 1220 910 11102cm2 • • 350 350 300 1220 1070 13054cm2 • • • 350 350 1220 1220 14884cm2 • • • 350 350 1520 460 6992cm2 300 300 300 250 250 1520 610 9272cm2 • 350 350 300 300 1520 760 11552cm2 • • 350 350 300 1520 910 13831cm2 • • • 350 350 1520 1070 16264cm2 • • • • 350 1520 1220 18544cm2 • • • • • D 1.3 The chimney or flue must be free from any obstruction. Any damper plates should be removed or secured in the fully open position, and no restrictor plates should be fitted. 1.4 The chimney should be swept prior to the installation of the appliance - unless it can be seen to be clean and unobstructed throughout its entire length. 1.5 Ensure that there is a smooth tapered transition from the fireplace opening into the chimney or flue. 1.6 The flue pull should be checked prior to installation of the appliance. Apply a smoke pellet to the flue or chimney opening and ensure that the smoke is drawn into the opening. If there is not a definite flow, pre-heat the chimney for a few minutes and re-test the flow. IF THERE IS STILL NO DEFINITE FLOW, THE CHIMNEY MAY REQUIRE ATTENTION - SEEK EXPERT ADVICE. 2. INSTALLATION OF THE GAS SUPPLY 2.1 Before installation, ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible. 2.2 Ensure that the gas supply is capable of delivering the required amount of gas, and is in accordance with the rules in force. 2.3 Soft copper tubing and soft soldered joints can be used, but must not be...
Dieses Handbuch ist für folgende Modelle:Kamine - Chamonix & Aspen (P)8119**UC (602.53 kb)
Kamine - Chamonix & Aspen (P)8120**UC (602.53 kb)
Kamine - Chamonix & Aspen (P)8128**UC (602.53 kb)
Kamine - Chamonix & Aspen (P)8135**UC (602.53 kb)