Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.3 ( )

Anleitung Chamberlain, modell DUALBRITE SH-5597

Hersteller: Chamberlain
Dateigröße: 267.23 kb
Dateiname: 598-1162-01.pdf
Unterrichtssprache:enes
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• Turns on lighting when motion is detected. • Automatically turns lighting off. • DUALBRITE® Timer. • Photocell keeps the lighting off during daylight hours. • LED indicates motion was sensed (day or night). This package includes: Lamp 6 Screws Holders (3 sizes included) Light ControlCover PlateSensor 2 Wire Connectors Mounting Strap Mounting Bolt Plastic Hanger Rubber Plug 2 Lamps (installed) Requirements • The Light Control requires 120-volts AC. • If you want to use Manual Override, the control must be wired through a switch. • Some codes require installation by a qualified electrician. • This product is intended for use with a junction box marked for use in wet locations. OPERATION Mode: On-Time: Works: Day Night Test 5 Sec x x Auto 1, 5, 20 min. x Manual Until Dawn* x * resets to Auto Mode at dawn. Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate. TEST TEST 1 5 20ON-TIMEOff 3 6 Dusk to DawnDUALBRITE®Put ON-TIME switch on the sensor bottom to TEST and the DUAL- BRITE® switch OFF. AUTO GasketMANUAL MODEON-TIMETEST 1 5 20... back on. 1 Second OFF then... Manual mode only works at night because daylight returns the sensor to AUTO. Flip the light switch off for one second thenbackontotogglebetweenAUTO and MANUAL MODE. ManualmodeworksonlywiththeON-TIMEswitchinthe1,5,or20position. Put the ON-TIME switch in the 1, 5, or 20 minute position. Mode Switching Summary Move ON-TIME Switch to 1, 5, or 20 minutes MANUAL MODE AUTO TEST Flip light switch off for one second then back on* * If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode. DUALBRITE® TIMER Light comes on half bright for selected time after dusk (Off, 3 hr., 6 hr., until dawn). If motion is sensed, the light turns on full bright for the ON-TIME (1, 5, or 20 minutes) then returns to dim mode. © 2006 DESA Specialty Products™ 598-1162-01 INSTALLATION For easy installation, select an existing light with a wall switch for replacement. CAUTION: To Avoid Fire Or Burn Hazards: • Allow fixture to cool before touching. The bulb and the fixture operate at high temperatures. • Keep fixture at least 2" (51 mm) from combustible materials. Do not aim at objects closer than 3' (1 m). • Use only T4 100W (max.), G8 tungsten halogen bi-pin 120 VAC lamps. For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock. . Swing the sensor head towards the clamp screw joint. For eave mount only: . Rotate the sensor head clockwise 180° so the controls face down. Controls Controls Clamp Screw Controls If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done. BULB INSTALLATION . The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap. . Route all fixture wires through the large holes in the gasket as shown. . Connect the junction box wires to the light fixture wires as shown.Twist together and secure with wire connectors. MOUNT THE LIGHT CONTROL White to WhiteBlack to BlackConnectanyfixturegroundwire(s)andthecoverplategroundscrewtothejunctionboxgroundwire. GasketMounting StrapMounting BoltRubber Plug . Place the Mounting Bolt through the front of the junction box cover. Push the small gasket hole over the Mounting Screw. . Make sure the wire connectors and wires are inside the junction box. Align the Mounting Screw with the center hole in the Mounting Strap.Secure the fixture to the Mounting Strap. . Push the Rubber Plug firmly into place. . Ifawetlocationjunctionboxwasnotused,caulkthewall plate mounting surface with silicone weather sealant. NOTE: When re-lamping, turn power off and let the fixture cool. . To remove lamp shade, loosen set screw 2 full turns with a small flat-head screwdriver.Turn shade counterclockwise and remove. . To remove bulb, pull straight out of fixture. . To replace bulb, push bulb pins into lamp socket. Check that the bulb is seated properly. . To reinstall lamp shade, place shade on fixture and align notches on shade with tabs on fixture. Turn clockwise. Tighten set screw firmly. . Adjust the lamp holders by loosening the lock nuts, WIRE THE LIGHT CONTROL but do not rotate the lamp holders more than 180° from the factory setting. WARNING:Turn power off at the fuse or circuit . Adjust lamp shades by loosening the set screws breaker. several turns, turn shades counterclockwise and . Remove the existing light fixture. remove.Reinstall the shades in the desired position . Install mounting strap to junction box using screws and tighten set screws. appropriate for your junction box. 2 598-1162-01 Lock NutsLamp ShadeSet Screw Keep lamps at least 2" (51 mm) from the sens...

Dieses Handbuch ist für folgende Modelle:
Überwachungstechnik - DUALBRITE SH-5597 (267.23 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien