Anleitung CFM Corporation, modell EF26FG

Hersteller: CFM Corporation
Dateigröße: 2.03 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Units with overhead lights (Fig. 9) use two (2) clear 120 Volt, 5 Watt, E-12 socket base light bulbs (small base, chandelier candle type) located above the logs. For convenience, if one of the light bulbs burns out, it may be easier to replace all of the light bulbs at the same time. Do not exceed 60 Watts per bulb for the ember bed bulbs and 5 Watts per bulb for the overhead lights. Use of higher rated bulbs may result in a fire, causing property damage, personal injury or loss of life. 1. Turn off power to the unit. 2. Let fireplace cool if it has been operating. 3. Open the front doors. 4. Locate two (2) screws that hold the refractory (brick patterned) bracket together with the ember bed. (Fig. 6) NOTE: Some units may have two (2) screws securing the refractories to the ember bed. These screws must also be removed. (not shown) Remove Screws Figure 6 FP1737 5. Remove those two (2) screws using an appropriate screwdriver. One screw is located on either side of the unit. 6. Pull the ember bed out of the unit by gently pulling towards you and only slightly upwards. Depending on the model, you can remove the refractory prior to .................................................................... removing the ember bed. Pull Here (both sides) Figure 7 FP1738 10 10009816 ........... ........................... 7. Looking into the opening of the unit under the ember bed, visually locate the light bulbs. 8. Remove the light bulbs by unscrewing them out of the bases turning them counterclockwise. You can use one hand to hold the light socket in place, if required. 9. Install the new light bulb(s) by turning the light bulb into the base clockwise. You can use one hand to hold the light socket in place, if required. 10. Reposition the ember bed. If required, gently raise the refractory panels, one at a time, to tuck the ember bed edge underneath them. 11. Reposition the refractory bracket, aligning the refractory in place as required. 12. Reinstall the two (2) screws removed in Step 5. Figure 8 Figure 9 4W (Max. 5W) Light Bulb FP1618 60W Light Bulbs • Maintenance of Motors ........... FP1739 Always disconnect the appliance from the main power supply and allow it to ................................. ........... cool before any servicing operation. The motors used on the fan heater and flame blower are pre-lubricated for extended bearing life and require no further lubrication. However, periodic cleaning/vacuuming of the appliance around the air intake and exhaust, as well as the fan heater is recommended. For heavy or continuous use, periodic cleaning must be done more frequently. If the heater blows alternating cold and warm air, check the fan for free movement and for debris restricting air flow. If the fan does not move freely, the unit must be turned off and the fan replaced immediately in order to prevent further damage to the unit. • Cleaning Cleaning of the touchpad label at the bottom front of the unit is to be done only using a soft cloth, slightly dampened in water (if needed, a small amount of dish soap can be added to the water) and dried using a clean, dry soft cloth. Cleaning of the screen diffuser is to be done using only water and a lint free cloth. DO NOT use any abrasive household cleaners as these products will damage the touchpad controls and the diffusing screen. WARNING: Make sure the power ........................... is turned OFF before proceeding. • Electrical Wiring Diagram Any electrical repairs or rewiring of this unit should be carried out by a licensed electrician in accordance with national and local codes. If repairing or replacing any electrical component or wiring, the original wire routing, color coding and securing locations must be followed. 6 1 7 6 LIGHT RETURN HEATER RETURN 1 REDREDBLACK FLAME MOTOR MOTOR N.O. + - LIGHT COM. WHITE BLACK/BLUE BLACKBLUE WHITE BLACK/BLUE RED LIMIT SWITCH BLUE FAN MOTOR LINE NEUTRAL NEUTRAL 2 WHITEGREEN LAMP RETURN LAMP 7 BLACK/BLUE 5 WHITE GROUND 3 5 6 5 2 8 9 4 4 5 4 6 WHITE8 BLACK/BLUE NOTE: EF22/26 use 2 instead of 3 light bulbs for flame and ember bed. WARNING: Disconnect Power Before Servicing 1. Fan/Heater 2. Circuit Board 3. Motor DC 4. Light Socket w/Wiring Assy 5. Light Bulb 6. Wire Clip 7. Bushing Snap 8. Strain Relief 9. Power Cord 16/3 FP1572 HEF wiring Any electrical re-wiring of this appliance must be done by a qualified electrician. This wiring must be done in accordance with local codes and/ or in Canada with the current CSA C22.1 Canadian Electrical Code, and for US installations, the National Electrical Code ANSI/NFPA NO 70. 12 10009816 Operating Instructions • Fireplace Control Functions All of the fireplace control functions can be accessed in two (2) ways: • Using a multifunction remote control unit. • Using touchpad control panel, located in the lower right-hand corner of the fireplace behind the door front. The infrared remote control relies on a line of sight and must be pointed at the touchpad control panel of the fireplac...

Dieses Handbuch ist für folgende Modelle:
Kamine - EF22 (2.03 mb)
Kamine - EF36 (2.03 mb)
Kamine - EF26 (2.03 mb)
Kamine - EF33 (2.03 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien