Login:
Stimmen - 4, Durchschnittliche Bewertung: 3.8 ( )

Anleitung Napoleon Fireplaces, modell SSBV-4035CNE

Hersteller: Napoleon Fireplaces
Dateigröße: 4.4 mb
Dateiname:
Unterrichtssprache:enfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Remove the glass enclosure panel (see Removing Glass Enclosure Panel on Page 7). -Remove the lintel securing screws (3) and thenremovethelintel.Oneofthelintelcabinet top holes is shown in Figure 7). -Removethescoopsecuringscrews(3)and then remove the scoop. See Figure 7. 4 -Remove the spill switch bracket securing screws (2), and pull the switch/bracket assembly,withlowvoltagewiresattached, throughthesidepanelslotintothefirebox. See Figure 8. 5 - Replace the spill switch. 6 - Reinstall the switch/bracket assembly. 7 - Reinstall the scoop and lintel. 8 - Reinstall the glass enclosure panel. 9 - Re-Installthebottomcontrolcompartment access door. 10 -The appliance should then relight and remain lit. If this does not occur, check unit for a blocked flue condition. Spill Switch (Blocked Flue Safety Limit) Location -See Figures 6, 7 & 8. Inside View of Firebox -Top/Right Side Intersection Figure6Wire Terminals Cabinet Corner Back of Spill Switch (high limit disc) Door Frame Figure8Spill Switch (limit disc) Bracket Securing Screws Spill Switch (limit disc) View Without Scoop Figure7Firebox Top Lintel Securing Screw Hole in Cabinet Top Scoop Securing Screws Scoop Lintel Securing Screw Hole in Cabinet Top Figure8Spill Switch (limit disc) Bracket Securing Screws Spill Switch (limit disc) View Without Scoop Figure7Firebox Top Lintel Securing Screw Hole in Cabinet Top Scoop Securing Screws Scoop Lintel Securing Screw Hole in Cabinet Top Firebox Top Outside Combustion Air Controls WARNING Do not operate the shutoff lever unless a completeoutside COM BUSTION air system has been installed with your appliance. Many appliances are equipped, when installed, with an outside (make-up air) vent system that isdesignedtoprovidetheappliancewithoutside make-up air for combustion when in operation. The combustion air control lever for the outside air system is standard on all appliances but should not be operated if the complete system is not installed. Refer to Figures 9 & 10. When thecompleteoutsideairventsystemisinstalled, theinstallerwillremovethesecuringscrewfrom the combustion air control lever located on the left side of the fireplace bottom opening. If the securing screw has not been removed and you have reason to believe that you have a complete outside air system, contact your distributor to have your appliance inspected for the presence of the complete system. DO NOT assume that you have this system in place. Operate the actuator through several cycles including the closed position. Ensuring proper operation and freedom of movement. Return the actuator arm to the closed position. Toopentheoutsideairshutter,removethebottom louvered control comartement door, reach into control compartment and pull the combustion air controlleverallthewayout.Theoutsideairshutter should be fully open when the fireplace is in use and completely closed when the fireplace is not beingused. Closingitwhennotinusewillprevent outside cold air from entering the dwelling. Outside Air Contro...

Dieses Handbuch ist für folgende Modelle:
Kamine - SSBV-3530CNE (4.4 mb)
Kamine - SSBV-3530CNE (4.4 mb)
Kamine - SSBV-3530CNM (4.4 mb)
Kamine - SSBV-3530CNE (4.4 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien