Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Superior, modell SSBV-3530CNE

Hersteller: Superior
Dateigröße: 4.4 mb
Dateiname: c99d5d00-26a7-46b6-af22-c158deb57680.pdf
Unterrichtssprache:enfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Installation must conform to local codes. In the absence of local codes, installation must complywiththecurrentNationalFuelGasCode, ANSIZ223.1 (NFPA 54). (InCanada,thecurrent CAN/CGA B149 installation code). Electrical wiring must comply with local codes. In the absence of local codes, installation must be in accordance with the National Electrical Code, NFPA70-(latestedition).(InCanada,thecurrent CSA C22.1 Canadian Electric Code). GENERAL INFORMATION Note: Installation and repair should be performed by a qualified service person. The appliance should be inspected annually by a qualified professional service technician. More frequent inspections and cleanings may be required due to excessive lint from carpeting, bedding material, etc. IMPORTANT It is imperative that the control compartment, burners and cir culating air passage ways of the appliance be kept clean. See Maintenance instructions on Pages5&6. Provide adequate clearances around air openings and adequate accessibility clearance for service and proper operation. Never obstruct the front openings of the appliance. Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies. Locate furniture and window coverings accordingly. These appliances are designed to operate on natural or propane gas only. The use of other fuels or combination of fuels will degrade the performance of this system and may be dangerous. Millivolt Models - BTU Input Millivolt models come standard with the manually- modulated gas valve; flame appearance and heat output can be controlled at the gas valve. The BTU Input for millivolt models is shown in Tables 1 & 2: NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. BTU Input - Millivolt Models Input (BTU) Manually-Modulated Gas Valves (millivolt models) NATURAL GAS Models Input Rate (BTU / HR) SSBV-3530CNM ,000 high 17,500 low SSBV-4035CNM 9,000 high 1,500 low Table 1 Input (BTU) Manually-Modulated Gas Valves (millivolt models) PROPANE GAS Requires Field Converion Models Input Rate (BTU / HR) SSBV-3530CPM ,000 high 17,500 low SSBV-4035CPM 9,000 high ,500 low Table 2 Electronic Models - Electronic models have a fixed rate gas valve. Input of electronic models is shown in the following table: Electronic Models with Fixed Rate Gas Valve Natural and Propane Gas Model Series Input Rate (BTU / HR) SSBV-3530CNE ,000 SSBV-4035CNE 9,000 Table 3 Fuel # Minimum Maximum 5.0" WC 10.5" WC Natural Gas (1. 4 kPa) ( .61 kPa) 11.0" WC 1 .0" WC Propane ( .74 kPa) ( . kPa) Table 4 Inlet Gas Supply Pressure (all models) Manifold Gas Supply Pressure (millivolt models) Fuel # Low High Natural Gas (Lo) . " WC (.55 kPa) (Hi) .5" WC (.87 kPa) Propane (Lo) 6. " WC (1.57 kPa) (Hi) 10.0" WC ( .49 kPa) Table 5 Manifold (eleFuel # Manifold (eleFuel # Natural Gas .5" WC (.87 kPa) Propane 10.0" WC ( .49 kPa) Table 6 Test gauge connections are provided on the front of the millivolt gas control valve, identified IN for the inlet and OUT for the manifold side....

Dieses Handbuch ist für folgende Modelle:
Kamine - SSBV-3530CNE (4.4 mb)
Kamine - SSBV-3530CNE (4.4 mb)
Kamine - SSBV-3530CNM (4.4 mb)
Kamine - SSBV-3530CNE (4.4 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien