1706 Canterbury Rd Greenville, NC 27858 Ph. 252.355.6789 Oysterdoctor@aol.com Efficiency Of Bacterial Disinfection By A Duct Mounted UV-AireO Air Purifier For: Table of Contents Table of Contents Background ..........................................................................................................................3 Organism.........................................................................................................................3 Testing Structure.....................
Over a thirty day period, the moisture content was measured at weekly intervals. Homes with the Eliminator installed saw a reduction of moisture levels to as low as 16% and 17%. A wood moisture level of 20% or less is considered ideal. Homes without the Eliminator showed no reduction in moisture content. “The Eliminator performed well, even under severe moisture problem conditions… the amount of air moved is sufficient to correct the problems present.” Cliff Consulting Columbia, S.C. Moisture Co
*The definition of a qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the precautions required, and has complied with all the requirements of the authority having jurisdiction. WARNING: Read the installation instructions carefully and completely before proceeding with the installation. GENE
7. Drill the marked mounting holes with a 1/8 inch diameter drill bit. Remove the marked filter opening with metal cutting shears or equivalent. 8. Attach filter cabinet to the appliance or duct work using #8 X 1/2 inch long sheet metal screws or pop rivets. Seal the housing connections with aluminum duct tape or equivalent. 9. Remove media filter from the plastic bag and discard the plastic bag. TIP: Write the installation date on filter next to directional arrow for future filter replacement r
Think of air circulation in terms of the circular motion of the air before and after the air filter. The air exiting the filter is exhausted at a higher velocity than that entering it. Consequently, exhaust being vented inside a building can have an effect on the pattern of air circulation. Air circulation patterns will vary depending upon which method is used and according to your specific shop setup. Figure 4 shows an example of good air circulation. Filter Figure 4. Good air circulation. The
An alternate method would be to use wall anchors. Whichever method you use, make sure the air cleaner is mounted in a sturdy fashion to prevent it from pulling loose. © 1997 Grizzly Industrial, Inc. G4702 & G4705 INSTALLATION INSTRUCTIONS The G4702 & G4705 Air Cleaners can be mounted on the floor, wall or a ceiling; whichever place is convenient. If mounting on a wall or ceiling, we recommend attaching the air cleaner to the wall or ceiling studs using sheetrock screws. This will require at
This will require at least four holes be drilled corresponding to the stud spacing. An alternate method would be to use wall anchors. Whichever method you use, make sure the air cleaner is mounted in a sturdy fashion to prevent it from pulling loose. © 1997 Grizzly Industrial, Inc.
• Try to place the unit where it is easy to access for turning it on, cleaning and maintenance. Filter Filter Figure 4. Good circulation. The air filter placement promotes circular air motion. Figure 5. Poor circulation. Placed too close to the wall, the air circulation short cycles leaving much of the room unfiltered. -10- G5955 Heavy-Duty Hanging Air Filter Filter Capacity The G5955 Hanging Air Filter is designed to recirculate the entire volume of air in a room measuring 25' X 25' X 8' approx
Calculate, how long it takes to circulate all the volume of air in a room with the double air filter; where W = Width, L = Length and H = Height of your room, in feet. The rate of air movement for the air filter is 1400 cubic feet per minute. W' x L' x H' = Minutes for circulating 1 time 1400 Step 2. Calculate how many times per hour the volume is recirculated through the double air filter by dividing 60 minutes by the amount of time it takes to circulate the volume once. The result is listed as