GENERAL PRECAUTIONS WARNING: Always disconnect the UV from the power source. Follow the procedures provided in this manual. Improper handling can result in death or serious injury. WARNING: Do not look directly at the UV lamp. This can cause retina/eye damage. WARNING: Do not touch the UV bulb. Any fingerprints or dirt will reduce the efficiency of the bulb and may cause it to explode. WARNING: Observe caution when inserting quartz sleeve to prevent breakage and cracking, which may result in injury and damage to unit. NOTE: When handling the UV bulb hold only the plastic-covered ends of the bulb. If the bulb has been touched, remove bulb and clean with alcohol before reinserting CAUTION: If water pressure exceeds 65 psi, a pressure regulator, set at less than 65 psi, must be installed before the Ultraviolet system. CAUTION: Install on cold water lines only. CAUTION: Do not install where system is exposed to direct sunlight. CAUTION: Do not use wicking or sealing agents for fitting connections. Teflon® tape is recommended. CAUTION: This system must be protected from freezing which can cause cracking of the filter housing and water leakage. CAUTION: Because of the product’s limited service life, and to prevent costly repairs or possible water damage, we strongly recommend that the bottom of all opaque housings be replaced every ten years. If the bottom of your housing has been in use for more than this period, it should be replaced immediately. Date the bottom of any new or replacement housing to indicate the next recommended replacement date. NOTE: Filter cartridge life varies depending on filter type, usage and water conditions. For the UVS-110 and UV-110 Allow a minimum of 12 inches clearance under the filter for changing the cartridge, and above the system to allow the UV bulb to be changed. For the UV-120 and UVBB-120 Allow a minimum of 20 inches clearance under the filter for changing the cartridge, and above the system to allow the UV bulb to be changed. ASSEMBLY INSTRUCTIONS See exploded assembly drawings on pages 2 and 3. CARTRIDGE REPLACEMENT (for UVS-110 and UV-110 only) Your cartridge should be replaced when there is a noticeable drop in water flow at the faucet or tap, and/or when unpleasant odors return (approximately every 6-9 months). 1. Turn off water supply to the system. 2. Open faucet to relieve water pressure to the housing. 3. Unscrew housing from cap. If housing sticks or is difficult to open use an Pentek spanner wrench. 4. Remove used cartridge from housing, remove Teflon® sleeve and discard cartridge. 5. Remove O-ring from groove below the threads of the housing and wipe groove and O-ring clean. Lubricate O-ring with silicone grease. Place O-ring back into the groove. With two fingers wipe or press O- ring down into the groove. NOTE: This step is important to ensure a proper filter seal. Make sure that the O-ring is seated level in the groove. 6. Insert a new cartridge into the sump making sure that it slips down over the ...

Dieses Handbuch ist für folgende Modelle:
Wasserfilter - PENTEK UV-120 (56.25 kb)
Wasserfilter - PENTEK UVBB-120 (56.25 kb)
Wasserfilter - PENTEK UVS-110 (56.25 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien