Login:
Sortierung : Dateiname ↑   heruntergeladen   Bewertung   Dateigröße ↑  
heruntergeladen wurde: 5   Dateigröße: 33 kb   Hersteller: ADT Security Services  
Kategorie: Überwachungstechnik
@name

For example, if you wanted to secure Door 5, at the following prompt: SECURE DOOR 1 2 3 4 5 6 7 8 Press 5 then ENT. The display will read: SECURE DOOR 1 2 3 4 X 6 7 8 This indicates that all doors are at a normal state, except for Door 5, which is secured. 16. Press ESC to leave this subfunction, or enter another door number to unlock. NOTE: Each of these subfunctions act as a toggle. To return a door to its normal state, follow the same procedure you used to change its state. For example, if Do

heruntergeladen wurde: 3   Dateigröße: 33 kb   Hersteller: ADT Security Services  
Kategorie: Überwachungstechnik
@name

The instructions for the commands listed in this reference are intended to replace those instructions in the Security System Owner’s Manual. Please refer to the Owner’s Manual for the operation of your new security system and its other basic Function List features. NOTE: This supplement should be placed inside the Security System Owner’s Manual. Access Level Control ............................................................... 3 Door Control Command 46 .........................................

heruntergeladen wurde: 1   Dateigröße: 708 kb   Hersteller: ADT Security Services  
Kategorie: Überwachungstechnik
@name

3 ARMING ....................................................................................... 3 Arming The System Prior To Leaving ..................................... 3 Arming The System Without Leaving ..................................... 3 System Not Arm (Ready Light Off) .................................. 4 DISARMING ...................................................................................... 5 Disarming Upon Entering The Premises ................................ 5 ALARM CONDI

heruntergeladen wurde: 19   Dateigröße: 312 kb   Hersteller: ADT Security Services  
Kategorie: Überwachungstechnik
@name

200 PLUS is a user-friendly security system that monitors your site’s detectors and alarms. Fully programmable, the FOCUS. 200 PLUS allows you to control hundreds of critical security functions from one menu-driven interface as simple to use as the automated teller machine (ATM) at your local bank. The ADT FOCUS. 200 PLUS consists of a central control unit, an operating panel, and up to 255 protection points. The control unit is protected by a heavy-gauge steel cabinet and protected by a tamper

heruntergeladen wurde: 0   Dateigröße: 507 kb   Hersteller: ADT Security Services  
Kategorie: Überwachungstechnik
@name

Ensure that no zones are unintentionally 4 bypassed when arming your system. Zones cannot be bypassed once the system is armed. Bypassed zones are automatically cancelled each time the system is disarmed and must be bypassed again, if required, before the next arming. Bypassing Zones With the system disarmed. 1. Press to enter the function menu. The keypad will display “Press 4 for < > Zone Bypass”. 2. Press or , then your [access code] (if required). The keypad will display “Scroll to < > Bypas

heruntergeladen wurde: 7   Dateigröße: 396 kb   Hersteller: ADT Security Services  
Kategorie: Überwachungstechnik
@name

Connection to party lines is subject to state tariffs. This equipment is hearing-aid compatible. Industry Canada NOTICE: The Industry Canada Label identifies certified equipment. This certification means that the equipment meets telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to the user’s satisfaction. Before installing t

heruntergeladen wurde: 0   Dateigröße: 393 kb   Hersteller: ADT Security Services  
Kategorie: Überwachungstechnik
@name

This revolutionary new concept in residential security makes using your system easier than ever before possible, because the system uses its computerized control panel to continually monitor the status of your entry door (and deadbolt) . It actually anticipates what command it should expect from you next- simply leaving you just one button to press to effortlessly operate your security system, whether you’re going, returning or staying in for the night. Now everyone in your family, young and old

heruntergeladen wurde: 3   Dateigröße: 85 kb   Hersteller: ADT Security Services  
Kategorie: Überwachungstechnik
@name

Its highly visible, back-lit keypad and built-in sounder alert you to a number of system events. Stylish design and ease-of-use make it ideal for property protection. Your security company can program the system to meet your individual needs. Your property is given its own English language description which appears in the command center display. About This Users Guide This users guide covers basic system commands, such as turning the system on and off. It is designed to be an everyday type of re

heruntergeladen wurde: 9   Dateigröße: 1 mb   Hersteller: ADT Security Services  
Kategorie: Überwachungstechnik
@name

All remaining points above 568 will report as fire alarm points. Document 50934 Rev B 5/15/00 PN 50934:B To access Type Mode, press the MODE key followed by the 4-digit code 8973 and then press the [ENTER/STORE] key. The ADT-UDACT will display three digits. For example, initial entry will display 01 0. To access Type Mode, press the MODE key followed by the 4-digit code 8973 and then press the [ENTER/STORE] key. The ADT-UDACT will display three digits. For example, initial entry will display 01

heruntergeladen wurde: 25   Dateigröße: 1 mb   Hersteller: ADT Security Services  
Kategorie: Überwachungstechnik
@name

Most fire related deaths occur at night when the occupants suffocate in their sleep from smoke and deadly gases, rather than from bums. To help reduce this risk, the following three-step program should be implemented: 1. Minimize fire hazards around the home. Smoking in bed, cleaning with flammable liquids such as gasoline, leaving children home alone, and unsafe Holiday decorations are some of the more common causes of household fire. 2. Install a fire warning system. The primary purpose of t





Kategorien