Connect the gas line before the firebox is enclosed in the finished wall. Gas line holes and other openings should be caulked with high temperature caulk or stuffed with unfaced fi berglass insulation. Ensure that a sediment trap is installed in the existing gas line, if not, install a sediment trap upstream of the heater to prevent moisture and contaminants from passing through trap to the heater controls and burners. Failure to do so could prevent the heater from operating reliably. An external regulator must be used on all propane (L.P.G). heaters, in addition to the regulator fitted to the heater, to reduce the supply tank pressure to 13" W.C. (maximum). Any copper tubing used to supply propane (L.P.G). from the tank must be internally tinned. WARNING Check Gas Type: The gas supply must be the same as stated on the heater’s rating plate. If the gas supply is different, DO NOT INSTALL the heater. Contact your dealer for the correct model. NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE. Hold heater regulator with a wrench to prevent movement when connect- ing to inlet piping. Connecting directly to an unregu- lated propane (L.P.G). tank can cause an explosion. IMPORTANT Pack unfaced fiberglass insulation material (not provided) around the gas line access hole on appliance and all exterior gas line penetration holes. TEST ALL CONNECTIONS FOR GAS LEAKS (FACTORY AND FIELD) Test all gas joints from the gas meter to the gas heater regulator for leaks using a gas leak test solution (also referred to as bubble leak solution). Note: Using a soapy water solution as a leak detection solution is not recommended because the soap residue that is left on the pipes/fi ttings can result in a false-positive leak detection reading if a gas leak sniffer is used. Soap residue can also result in corrosion over time. DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS. Leak Test Procedure: Turn on gas supply and test for gas leaks using a gas leak test solution. A. Light the appliance (refer to the lighting instructions label provided with gas logs). B. Brush all joints and connections with the gas leak detection solution. If bubbles are formed, or gas odor is detected, turn the gas control knob (off/pilot/on) to the “OFF” position. Either tighten or refasten the leaking connection, then retest as described above. C. When the gas lines are tested and found to be leak free, rinse off the leak testing solution from gas line fi ttings. IMPORTANT WARNING Firebox Framing Construct firebox framing following Figures 9 through 11 and Table 1 on Page 11 for your specific installation requirements. Refer to Figure 8 on Page 10 for fi rebox dimensions. The firebox may be installed directly on a combustible floor or raised on a platform of an appropriate height. Do not place firebox on carpeting, vinyl or other soft floor coverings. It may, however, be placed on flat wood, plywood, particle board, metal or other hard surfaces which extend the full width...
Dieses Handbuch ist für folgende Modelle:Ventilatoren - UVFRC-3628 (1.06 mb)
Ventilatoren - UVFRC-3628 (1.06 mb)
Kamine - UVFRC-3628-H (1.06 mb)
Kamine - UVF-36 (1.06 mb)