Login:
Stimmen - 5, Durchschnittliche Bewertung: 4 ( )

Anleitung Applied Energy Products, modell XX100

Hersteller: Applied Energy Products
Dateigröße: 814.4 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• Masonry drill, hammer and chisel (or core drill equipment if available). • Mortar to make good the hole around the ducting. If window/panel mounting the fan you will also need • XXGK4 Glass Kit. • You will need a window pane between 3mm and 6mm thick (preferably 4mm). • Do not install in glass 3mm thick if the window pane area is more than 0.2 sq. m. • If installing in sash windows you should mount the fan in the upper window. Secure the upper sash in the closed position and fit stops just below the level of the fan, to prevent damaging it when the sash is raised. • If ceiling mounting the fan, an XXCK4 Ceiling Kit is required and appropriate ancillaries for termination. For example: 1. Termination ducting kit. 2. Soffit board termination grille. 3. 100mm diameter flexible ducting. If installing in a vent, an XXVK4 Vent Kit is required. Where to locate the fan • Locate it as high as possible. • At least 110mm from the edges of the wall mounting surface to the centre of the hole. • As far away as possible from and opposite to the main source of air replacement to ensure airflow across the room (eg. opposite the internal doorway). • Near the source of steam or odours. • Not where ambient temperatures are likely to exceed 50oC. • If installed in a kitchen fans must not be mounted immediately above cooker hob or eye level grille. • If installing in a room containing a fuel burning device which has a non-balanced flue, it is the installer's responsibility to ensure that there is enough replacement air to prevent fumes being drawn down the flue when the fan is operating up to maximum extract. Refer to local Building Regulations for specific requirements. • Exhaust air must not be discharged into a flue used for exhausting of fumes from appliances supplied with energy other than electric. Requirements of all authorities concerned must be observed for exhaust air discharge and intake flow rates. • When intended for use in possible chemical corrosive atmospheres, consult our Technical Department or your distributor. • This electrical product is rated at "IPX5", and can be installed anywhere in a shower room or bathroom. Installing the isolating switch & cables 1. Check that the electrical rating shown inside the backplate matches your mains supply. 2. Check there are no buried pipes or cables e.g. electricity, gas, water behind the switch location (in the wall or above the ceiling). If in doubt seek professional advise. 3. Isolate the mains supply. 4. Lay in the cable from the isolating switch to the fan location via the on/off switch (if required). 5. Lay in the cable from the isolating switch to the point of connection to the mains supply. Warning: Do not make any connections to the electrical supply at this stage. 6. Install the isolating switch and on/off switch (not supplied). 7. Make all connections within the isolating switch and the on/off switch (if required). Note: on/off switch must be situated so that it cannot be touched by persons making use of the bath or shower. WARNING: DO NOT MAKE ANY CONNECTIONS TO THE ELECTRICAL SUPPLY AT THIS STAGE. If in doubt, seek professional advice. Preparing the hole If working above ground floor level, appropriate safety precautions must be observed. WARNING: EYE PROTECTION MUST BE WORN DURING ALL DRILLING AND CHISELLING OPERATIONS. If installing in a wall 1. Check there are no buried pipes or cables in the wall or obstructions on the outside e.g. electricity, gas, water. 2. Mark on the wall the centre of the duct hole. The centre of the hole should be at least 110mm away from the edge of the mounting surface. 3. Use this centre to mark a circle to suit the wall duct (115mm diameter). If core drill equipment is available: 4. Use as directed by core drill manufacturer. If core drill equipment is not available: 4. Drill a centre hole right through the wall. 5. Cut the hole. Do not cut right through the wall. (The recommended method is to drill a series of holes, close together, around the edge of the cutting...

Dieses Handbuch ist für folgende Modelle:
Ventilatoren - XX100P (814.4 kb)
Ventilatoren - XX100T (814.4 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien