|
Anleitung Zusammenfassung
Five seconds later the alarm will sound and the red Alarm Indicator Light will flash continuously. You can also test for movement with the Nursery Unit set to the “Tic Off” position. In this case, you will not hear a constant ticking when you touch the mattress. When you remove your hand from the mattress the Movement Indicator Light will stop flashing, a pre-alarm beep will sound after 15 seconds, and five seconds later the alarm will sound and the red Alarm Indicator Light will flash continuously. To turn off the alarm, turn the Nursery Unit off or pat your hand lightly on the mattress so the Sensor Pad will redetect movement. The red Alarm Indicator Light on the Nursery Unit will continue to flash for one minute and it will then revert to green. If the alarm does not sound when you are not touching the mattress, the Sensor Pad may be detecting a continuous vibration from another source from inside and/or outside your baby's room. Common sources of this interference are crib mobiles, fans, washing machines, or even loud music. Therefore, it is very important to make sure all vibration sources are eliminated before using the monitor. Place the crib near a solid supporting wall and away from strong air currents. Do not use crib mobiles or accessories that may cause vibrations. Avoid contact with the crib when the monitor is in use. If you find the alarm will still not sound when you are not touching the mattress or crib, the monitor is on, and you have removed all external sources of vibration, the sensitivity level may need to be decreased. Please refer to the Movement Sensitivity Adjustment section on page 11. 3. Testing for Battery Power. Verify that the units are operating on battery power by installing four AAA batteries in each unit and unplugging the AC adapters. The green Power Indicator should light up on all units. 13 Care and Maintenance Care and Maintenance Disconnect all units and remove all batteries before cleaning. Clean the exterior surface of the units with a soft dry or slightly damp cloth. Do not spray with cleaning products or solvents. Do not submerge in water or any other liquid. During long periods of non-use, remove all batteries from their compartments and unplug the AC adapters. Troubleshooting Problem Possible Cause Solution False alarms Baby was removed from crib and the Nursery Unit was not switched off. Turn the Nursery Unit off. The turquoise side of the Sensor Pad is not facing up. Make sure the turquoise side is facing up. The Sensor Pad is not detecting your baby’s movements because the sensitivity level is too low. The sensitivity level may need to be increased. Refer to the Movement Sensitivity Adjustment section on Pg. 11. Sensor Pad is not in full contact with the crib mattress or is not resting on a flat, firm surface. Make sure there is no thick bedding between the mattress and the Sensor Pad. The Sensor Pad must rest on a firm surface. If the crib has a spring or slat base, place a piece of Masonite board measuring at least 13” on all four sides and .” thick. Baby has moved far away from the Sensor Pad. Make sure the Sensor Pad is positioned correctly in the crib. Sensitivity level may need to be adjusted. Refer to the Movement Sensitivity Adjustment section on Pg. 11. 14 Problem Possible Cause Solution Problem Possible Cause Solution Sensor Pad cord is not connected Unplug and reconnect the cord. properly to the Nursery Unit. False alarms Nursery Unit is detecting Avoid contact with the crib when Alarm will not sound movement when crib is being monitor is on. touched. Place crib near a solid supportingNursery Unit is detecting wall to avoid Sensor Pad from movement from outside the crib detecting movement from outside thesuch as motorized devices, strong crib. Turn off crib mobile, fans, loud drafts, etc. music or anything else that may cause vibrations. You may need to decrease the Sensor Pad sensitivity level is set sensitivity. Refer to the Movement too high. Sensitivity Adjustment section on Pg. 11. Make sure there is no loose bedding Sensor Pad is not in full contact Movement Indicator Light on between mattress and the Sensor with crib mattress, or the mattress Nursery Unit is flashing orange Pad. The Sensor Pad must rest on a is not resting on a hard surface. (monitor is barely detecting hard surface. If the crib has a springmovement). or slat base, place a piece of Masonite measuring at least 13" on all four sides and 1/4" thick on top of the base. Make sure Sensor Pad is Baby is in a very deep sleep or has positioned correctly in crib. moved away from Sensor Pad to The sensitivity level may need the edge of the crib. to be adjusted. Refer to the Movement Sensitivity Adjustment section on page 11. Bring Parents' Unit closer to Parents' and Nursery Units are too Nursery Unit. far apart. No sound is being transmitted. Check or replace batteries. Batteries are low or improperly installed. AC adapters are not connected Check connections or change properly or ele...
Dieses Handbuch ist für folgende Modelle:Babyphone - Angelcare 1750296 (928.64 kb)
Babyphone - Angelcare ISPD026BB (928.64 kb)