|
Anleitung Zusammenfassung
6. Remove the wire and pass it through the upper hole of the mounting plate and connect to the terminal screws on the rear of the wall inlet (Figure 11). 7. Angle the mounting plate and elbow into the previously cut hole in the wall and make the connection with the tubing (Figure 20). 8. Align the inlet screw holes with the mounting plate holes and lightly press the inlet into place, guiding any extra wire back through the mounting plate as you go. Attach wall inlet to mounting plate with provided screws making sure mounting plate is properly seated in hole (Figure 12). NOTE: Do not cement wall inlet to mounting plate, the built in mounting plate gasket will provide a positive seal. Installing the Tubing NOTE: When installing the tubing, start at the farthest inlet and work towards the power unit. Keep the tubing as straight as possible with the least amount of elbows and tees as possible to ensure maximum performance of your system. When installing tees or elbows, make sure the curve in the fitting is aligned so that the air flow is towards the power unit. 1. Measure the length of tubing needed to connect into the main trunk line, adding approximately 3/4" of tubing for insertion into fittings. 2. Cut the tubing, taking care to keep the straight square edge. The use of a miter box is recommended (Figure 6). 3. Remove rough edges with a utility knife or coarse sand paper (Figure 7). 4. Dry fit all pieces and ensure proper fit and alignment before cementing. 5. When dry fitting tubing, run low voltage wire (18 gauge, two conductor) by securing to tubing with tape. Allow approximately 6" of excess wire for connection to each inlet (Figure 8). NOTE: PVC solvent cement “welds” the fitting to the tubing through a chemical reaction to produce an air tight seal. It is important to make sure all surfaces are clean and free of burrs to ensure a proper seal. 6. Once all tubing has been cut, cleaned, and checked for fit, apply model CVFA35 PVC cement (not included) or equivalent cement to the outside of the tubing covering about 1". DO NOT allow any of the cement to enter the inside of the tubing (Figure 9). 7. Insert tubing with cement into fitting with a twisting motion to ensure the cement has been evenly spread. Check that the tubing is evenly seated in the fitting and is aligned properly with the rest of the line (Figure 10). Installing the Power Unit 1. Determine a mounting location within 5 feet of a grounded electrical outlet and install the included mounting bracket (located inside of collection canister during shipping) using at least two appropriate screws (not included) for the wall material (Figure 21). The bracket must be level and mounted high enough to allow a minimum of 18" from the floor to the bottom of the collection canister. Power Unit Bracket Cross Bolt MountingBracket Screw Holes ExhaustIntake AKCVM1 Sound Muffler Figure 21 Figure 22 2. Hang power unit on bracket so that it is properly seated between the two brackets of the power unit and tighten cross bolt (Figure 21). 3. Make tubing connections by cementing intake tubing (from the inlets) to the intake valve and connecting exhaust tubing to the exhaust valve. An optional model AKCVM1 sound muffler (not included) can be installed to the exhaust tubing to reduce the sound of the exhaust air (Figure 22). NOTE: Exhaust should not be vented into a wall, ceiling, or concealed space within the home. It is best to exhaust to the outdoors. 000000 Rev A. 3-05 4 of 16 Wiring 1. 2. Make connections to low voltage wire from inlet to inlet in parallel. Connect any low voltage wire along trunk and branch lines using suitable wire connectors. Connect the low voltage wire to crimp connectors located on the top outside of the power unit (Figure 23). Low VoltageWire Inlets To Other Inlets Low VoltageWire CrimpConnector Power Unit Lead Figure 23 Plug the power unit’s grounded cord into a 120 volt grounded receptacle. Check the System 1. Make sure all inlets are closed and the collection canister is in place. Switch the power on using the manual power switch on the power unit to test. 2. Test the inlets by inserting the power hose. The power unit should turn on and begin suctioning. Check for any air leaks in the system. Maintenance CAUTION: MAKE SURE POWER UNIT IS UNPLUGGED BEFORE SERVICING THE UNIT. 1. The only regular maintenance your system will need is for the collection canister to be emptied. Usage will dictate how often this needs to be done. To empty the canister, release the two clips on either side of the canister and slide off. When reinstalling, make sure the canister is properly seated in the rubber gasket. 2. Your unit is equipped with a self cleaning filter and it should not be removed. If an excess of debris has built up on the filter you can simply shake it off. It is recommended that you place a large plastic garbage bag under the unit when doing this. CAUTION: DO NOT USE GASOLINE, BENZINE, THINNER, HARSH CLEANSERS, ETC.,...
Dieses Handbuch ist für folgende Modelle:Staubsauger - AKCV1380 (117.64 kb)
Staubsauger - AKCV1225, AKCV1380, AKCV1310 (117.64 kb)