Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Hunter Fan, modell 47300A

Hersteller: Hunter Fan
Dateigröße: 670.73 kb
Dateiname: 41665.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Weekday program ¦ Press to display M – F programs. Programs ¦ Press repeatedly to cycle through the 4 programs. 1 Weekend ¦ Press to display M – F programs. NOTE: Time and Temperature display will be blank when at least one weekday program is different. ¦ Press to change to Sa – Su. Again, if the display is blank, one of the weekend programs is different. Daily Programs prog day program ¦ Press to display the Sa – Su programs. Programs ¦ Press repeatedly to cycle through the 4 programs. program 3 M TH WT F prog day 41665-01.pmd 22 9/30/03, 4:53 PM program prog day prog day ¦ Press again to change to Monday’s program. Daily Programs ¦ Continue pressing to cycle through each day. (cont.) ¦ Press repeatedly to cycle through the 4 programs. 1 hold ¦ Press to return to normal mode. /return ¦ After 15 seconds, the thermostat will return to normal mode automatically. NOTE: Programs take affect as soon as the thermostat returns to normal mode. If you are armchair programming the thermostat, slide the system selector to the OFF position before mounting the thermostat to the wallplate. Reviewing the Current Temperature Setting ¦ Current time and temperature. ¦ Press for 1 second or less. or ¦ Set Temperature is shown above current room temperature. 3 HEAT TEMP ¦ If held for over 1 second, Temporary Manual Override mode is entered. Refer to the next page. 3 SET TEMP 41665-01.pmd 23 9/30/03, 4:53 PM 24OPERATION System Selector Switch The System Selector switch on the front of the thermostat determines the operating mode of the thermostat. You may select COOL, OFF, HEAT. NO TE: Anytime you install or remove the thermostat from the wallplate, slide the System Selector to the OFF position to prevent the possibility of a rapid system On-Off. off cool heat Fan Switch system The Fan switch should normally be located in the AUTO position. The Fan will be fan turned on along with normal operation of your system. In a normal gas or oil furnace, auto the Fan will be turned on by your furnace after its warm-up delay. For electric heat, air conditioning, and heat pump operation, the Fan will turn on with the system. on To run the Fan on continuously, slide the Fan switch to the ON position. 41665-01.pmd 24 9/30/03, 4:53 PM Temporary Manual Override To temporarily change the current set temperature without affecting your program: or or hold /return ¦ Press and hold for about 1 second to enter Manual Override mode. When display flashes, you can release the key. ¦ Press again to change to your desired Set Temperature. Hold the key for 2 seconds to fast-advance the Set Temperature. ¦ Press to return to normal mode, or wait 5 seconds for it to return automatically. ¦ The current program number will flash to signify the Temporary Override. ¦ At the next program change time, the Temporary Override is cancelled, and the next program temperature becomes the setpoint temperature. SET TEMP 3 COOL TEMP 3 To end the Temporary Manual Override: hold ¦ Press and wait for HOLD to display on the LCD. ¦ Press again. This will return the set temperature to the current program set temperature. /return 41665-01.pmd 25 9/30/03, 4:53 PM 26OPERATION Permanent Manual Override To hold your Manual Override for vacation or just an extended period of time: hold ¦ Press to make the current program temperature the HOLD temperature. HOLD will be displayed on the /return LCD, and the Program number will disappear. ¦ Follow the Temporary Manual Override instructions above to change the Permanent Manual Override temperature. ¦ You can confirm the held set temperature by pressing for less than 1 second. HOLD To end the Permanent Manual Override: hold ¦ Press again. The thermostat will return to the current program, and the HOLD display will be canceled. /return 41665-01.pmd 26 9/30/03, 4:53 PM Vacation Override (Programmable Hold) This thermostat can hold a fixed temperature for a selected number of days (up to 30). After the selected number of days, the thermostat will return to normal program operation. This feature allows you to return home to your normal comfort setpoint temperatures. hold ¦ Press and hold for 2 seconds. Display will change to show a 1 day hold. /return HOLD day/time hold or /return ¦ Press to select the number of days to set the vacation hold temperature. In this example, 14 is used. ¦ Press to set the desired temperature. ¦ Press to return to normal mode, or wait 5 seconds for it to return automatically. ¦ HOLD will be shown on the LCD, and “VACA” will alternate with the time. HOLD HOLD 41665-01.pmd 27 9/30/03, 4:53 PM 28OPERATION Home Today This Hunter patented feature allows you to quickly and temporarily override your energy saving program setting on days when you are normally away from home with one key press. ¦ Press to enter the Home Today override. The highest program temperature for today will be selected from your programs in Heat mode and become the set temperature. (In Cool mode, Home Today will select the lowest program temperature ...

Dieses Handbuch ist für folgende Modelle:
Steuerungen & Regelgeräte - 47300A (670.73 kb)
Steuerungen & Regelgeräte - 47300A (670.73 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien