Login:
Stimmen - 2, Durchschnittliche Bewertung: 4.5 ( )

Anleitung Milwaukee, modell LSVFSD-LP

Hersteller: Milwaukee
Dateigröße: 1.92 mb
Dateiname: 7e58aa99-f610-4b20-ab87-3fc018334a73.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Consumer: Retain This Manual For Future Reference. In the Commonwealth of Massachusetts: • Installation must be performed by a licensed plumber or gas fitter • See Table of Contents for location of additional Commonwealth of Massachusetts requirements Report No.116-L-49-5 US Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS: • Do not light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow your gas supplier's instructions. • If your gas supplier cannot be reached, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. WARNINGS • Hot! Do not touch! This appliance will be hot during operation and will retain heat for a while after shutting off the appliance. Severe burns may result. • Carefully supervise children in the same room as appliance. • Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier. • Do not build a wood fire. Do not burn wood or other material in these appliances. • Carefully review the instructions supplied with the decorative type unvented room heater for the minimum fire place size requirement. Do not install the appliance in the fireplace, unless the fireplace meets the minimum dimensions required for the installations (see Page 3). • This is an unvented gas log appliance. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Combustion and Ventilation Air Section on Page 5. • Important: Read and understand these instructions completely before installing your unvented room heaters. • This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. If the gas supply differs, DO NOT INSTALL the appliance. Contact your dealer to obtain the correct appliance. • This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where not prohibited by local codes. • Lennox™ vent free gas logs are designed for use as a supplemental heater. They are not intended for continuous use as a primary heat source. IMPORTANT SAFETY AND WARNING INFORMATION READ THIS MANUAL IN ITS ENTIRETY AND UNDERSTAND THESE RULES TO FOLLOW FOR SAFETY. WARNINGS If the information in this manual is not fol lowed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. • Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition. • Do not place clothing or other materials on or near the heater. • Young children should be carefully supervised when they are in the same room with the appliance. • Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. • Any change to this heater or its operating controls can be dangerous. Improper installation or use of this appliance can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning. • Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with head aches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Have the Vent- Free Gas Heater serviced by a qualified technician as it may not be operating correctly. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes. • Any safety screen or guard removed for servicing an appliance must be replaced and/or closed prior to operating the heater. • Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional ser vice person. More frequent cleaning may be required duetoexcessivelintfromcarpeting,beddingmaterial, etc. It isimportant thatcontrol compartments,burners and circulating air passageways of the appliance be kept clean. • This appliance is for installation only in a solid-fuel burning masonry or UL 127 factory built fireplace or in a listed ventless firebox enclosure. It has been design certified for these installations. Exception: DO NOT install this appliance in a factory-built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs. WARNINGS • Allow the appliance to cool ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien