Anleitung Honeywell, modell PERFECT WINDOW ER150C

Hersteller: Honeywell
Dateigröße: 189.24 kb
Dateiname: fce5a08d-cebb-4933-9d5d-e613126a9ff5.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


For most installations, the ventilator will normally be set to operate continuously on low speed with the option of going to high speed as the need arises. For example, if you are entertaining and there is a large number of people present (some may be smoking), the ventilator should be switched to high speed. YOUR VENTILATOR MAY BE SET TO HIGH SPEED BY: 1. selecting the highest speed on the ventilator or 2. if the system includes an optional remote control, switch it to the ON position. Maintenance Instructions for your Fresh Air Ventilation System WARNING Electrical Shock Hazard. Can cause personal injury or equipment damage. Disconnect power supply before performing maintenance. The Perfect Window. Fresh Air Ventilation System must be maintained on a regular basis for best efficiency. Honeywell recommends that the ventilator be cleaned and checked at least twice a year, preferably at the beginning of each heating and cooling season. Check and Clean EXTERIOR HOODS Exterior hoods should be inspected at least once a month. Be sure exhaust and fresh air supply hoods are not blocked up or restricted by leaves, grass or snow. In winter, it is especially important to make sure snow is not blocking the hoods or that frost has not built up on the wire mesh (bird screen). 69-1563-1 6 ER150 AND ER200 Perfect Window. FRESH AIR VENTILATION SYSTEMS CORE GUIDE CHANNEL FILTER FILTER CLIP M11899 ER150 AND ER200 Perfect Window. FRESH AIR VENTILATION SYSTEMS CORE GUIDE CHANNEL FILTER FILTER CLIP M11899 WARNING Carbon Monoxide Hazard. Can cause personal injury or equipment damage. Hood blockage can cause a change of pressure in building which can lead to possible spillage from combustible appliances. AIR FILTERS Air filters should be cleaned twice a year. The standard filters supplied with your ventilator are removable and washable. 1. Open access door and slide out core. Refer to Core Maintenance section for cleaning instructions. 2. Remove filter clip. 3. Remove filters from the core and rinse with water or a combination of soap and water. Do not clean in a dishwasher. 4. After cleaning, place filters (wet or dry) back in their position and reattach the retaining clip. CORE IMPORTANT Do not wash the core with water or other fluids. Clean the core twice each year using only a vacuum cleaner. 1. Open the access door and carefully grip the ends of the core and pull evenly outward. The core can be snug, but it will slide out of the cabinet. NOTE: Do not handle the fins because damage can occur. 7 69-1563-1 ER150 AND ER200 Perfect Window. FRESH AIR VENTILATION SYSTEMS ER150 AND ER200 Perfect Window. FRESH AIR VENTILATION SYSTEMS . Once out of the cabinet, remove the filters (refer to Air Filter Maintenance section). 3. When the core is dry, clean it with only a vacuum cleaner. Vacuum the filter sides of the core by pulling any dirt back out of the core, not by pulling dirt all the way through the core. 4. Reinstall the clean filters. 5. Reinstall the clean core. TO INSTALL THE CLEAN CORE: 1. First mount the bottom core guide into the bottom Core Guide Channel. 2. Mount either side core guide, followed by the other side. 3. Mount the top core guide into the top Core Guide Channel. 4. With all four corners in place and the core straight and even, push on the core center until the core slides to the back of the cabinet. NOTE: The core is designed to appear to protrude from the cabinet approximately 1/8 in. (3mm) so the access door fits tightly against the core. GENERAL MAINTENANCE Twice a year, wipe the inside of the cabinet with a damp cloth to remove dirt, bugs and debris that can be present. FANS If the fans accumulate dirt, it could cause an imbalance and excessive vibration of the ventilator. A reduction in air flow can also occur. In a newly constructed house, this often happens within the first year due to heavy dust residue in the entire system. It can also occur periodically depending on the outdoor conditions. If you suspect that service is required, please contact the ventilator installer or your local HVAC contractor. 69-1563-1 8 ER150 AND ER200 Perfect Window. FRESH AIR VENTILATION SYSTEMS ER150 AND ER200 Perfect Window. FRESH AIR VENTILATION SYSTEMS Describing Perfection The m...

Dieses Handbuch ist für folgende Modelle:
Ventilatoren - PERFECT WINDOW ER150C (189.24 kb)
Ventilatoren - PERFECT WINDOW ER200C (189.24 kb)
Ventilatoren - PERFECT WINDOW ER200C (189.24 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien