Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Avanti, modell IM12-IS

Hersteller: Avanti
Dateigröße: 432.47 kb
Dateiname: im12-is.pdf
Unterrichtssprache:enes
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The default cube size from the factory is set at LARGE. Each time you press this button the cube size selection will change between Small and Large. The chosen mode shall stay as selected unless changed or there is a power failure. For the most efficient operation when ambient temperature is below 15°C (59.F) use the small cube size setting. LED INDICATORS POWER INDICATOR (GREEN) The indicator above the word POWER will illuminate green when the unit is turned on. ICE SIZE INDICATOR (GREEN) (S) small or (L) large. The indicator above the selected cube size will be illuminated green. ADD WATER INDICATOR (RED). The ice maker automatically checks the water level in the tank. If the water level is too low the indicator will illuminate in RED and will stop working automatically. Once you add water to the unit the indicator will turn off and will resume normal operation. ICE FULL INDICATOR (RED). When the ice-bin is full, the indicator will illuminate in RED. The indicator will remain lit until the ice in the bin either melts away slowly or has been removed. The unit will stay in a “Standby” mode until the ice has been removed / melted at which time the unit will automatically start operation as normal. Operating Instructions Starting your Ice maker • Open the top cover and remove the ice basket. • Remove any dust or objects that may be in the water tank • Fill the water tank up to the area marked “MAX”: • Select desired ice cube size by pressing the “ice size” selector (Small or Large). • The ice-maker will automatically check the water level in the reservoir periodically. The ice maker will detect any shortage of water and will stop the ice-making cycle, the ADD WATER indicator will be lit. Press the POWER button and fill the reservoir with water. Press the ON/OFF button again to restart the ice-making cycle or wait 3 minutes after the ADD WATER indicator goes out as the ice-maker will begin It’s normal operation cycle automatically. • When the ice cubes are collected and reach the bin sensor, the ice maker will stop operating and the ICE FULL indicator will be lit. • There are two sizes of ice cubes available, therefore the larger the ice cube selected, the longer the time it will take to complete the cycle. When the ambient temperature is lower than 15°C (59.F), the small ice cubes sizes are recommended to avoid ice cubes clumping together. • For best performance, water temperature should be between 7°C (45.F) and 35°C (95.F) and ambient between 15°C (59.F) and 25°C (77.F). Getting Ice from the Ice-bin • Open the top cover to access the ice basket. • Remove the amount of ice as desired and close the top. CARE AND MAINTENANCE Caution Failure to unplug the ice maker could result in electrical shock or personal injury. . Cleaning Your Ice Maker • To ensure the cleanliness of the ice cubes, water in the reservoir should be replaced every 24 hours. • Remove the drain plug to drain remaining water from the water reservoir when the ice maker will not be used for long period of time. Screw the drain plug back in place after the water has been drained. • Always change with fresh water before starting ice production at initial installation or after long shut-off periods. • Please clean your Ice maker regularly. When cleaning, unplug the unit and remove the ice cubes. Use a diluted solution of water and vinegar to clean the inside and the outside surface of the Ice maker. Do not spray Ice maker with chemicals or diluted agents such as acids, gasoline or oil. Rinse thoroughly before starting. . Space Requirements • During transportation, the incline angle of the cabinet should not be over 45° • Do not turn the Ice maker upside down. Problems could occur in the compressor and sealed system. • The Ice maker should be placed horizontally on a properly leveled surface. • To ensure proper ventilation for your Ice maker allow 6” of space at the top, the back and on each side. • Before using the Ice maker for the first time, please wait 2 hours after positioning it. • Clean the inner liner, ice-bin, water box, water cup frequently. IMPORTANT: Do not install the Ice maker near an oven, radiator, or other heat source. . Power Failure Most power failures are corrected within a few hours and should not affect the temperature of your ice maker if you minimize the number of times the ice-bin is opened. If the power is going to be OFF for a longer period of time, you need to take the proper steps to disconnect your appliance. PROBLEMS WITH YOUR ICE MAKER? You can solve many common ice maker problems easily, saving you the cost of a possible service call. Try the suggestions below to see if you can solve the problem before calling the servicer. TROUBLESHOOTING GUIDE Problem Possible Cause Suggested Solutions The compressor works abnormally with a buzzing Noise. The voltage is lower than recommended. Stop the ice maker and do not restart until the voltage is normal. Water shortage indicator Light is on. There is not enough water in the r...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien