|
Anleitung Zusammenfassung
These parts should be kept on hand to prevent loss time due to a minor problem. PART NUMBER DESCRIPTION QUANTITY KE54602 SCRAPER BLADE 1 KE54608 SPRING 3 KE01911 RETAINING KNOBS 1 FA05002-8 "O" RING 3 KE54594 PIN 1 KE54834-4 SOLENOID VALVE 1 KE55248 BUNA-N O-RING 5 KE55255 BUNA-N O-RING 5 FA05002-46 O-RING, FOOD GRADE, SIZE A0123, EPDM E 692-75 5 KE52154-3 GASKET, SANI CLAMP, 1 1/2” WHITE TEFLON 5 KE55297-3 GD2 STANDARD ACTUATOR 1 KE52936-2 FUSE, 15 AMP 6 SE50354 PEN TIP, RED (PKG. OF 5) 1 SE50354 PEN TIP, GREEN (PKG. OF 5) 1 The following is a recommended list of space parts that may be required if the service agency is of some distance away or if down time must be kept to a minimum and spare parts are required for the service agent on site. PART NUMBER DESCRIPTION KE54834-4 SOLENOID VALVE KE55253 AIR OPERATED CYLINDER KE53469-4 IGNITION MODULE KE00458 SOLID STATE CONTROL KE50753-7 RELAY KE00515 THERMISTOR KE50753-10 RELAY, 120 V HOT COLD WATER BYPASS KE02274 CAPACITOR ASSEMBLY KE603208-9 CONTACTOR CARTRIDGE, NORMALLY OPEN KE603208-8 CONTACTOR CARTRIDGE, NORMALLY CLOSED KE50753-10 RELAY QUANTITY AC INVERTER PROGRAMMING INSTRUCTIONS The WFC Series AC Inverters come wired for external use and must be installed for use in a side panel control (See WIRING DIAGRAMS). Refer to owners manual for complete instructions and explanations. Manual used for the following was FORM 1094. After installation is complete the inverter must be reprogrammed to Cleveland's modifications of the factory settings. All modifications are achieved in Access Level 2. 1. Turn agitator power on. The top four LED indicators will illuminate momentarily - wait for the three green LED's to go out before proceeding. 2. Press the PROGram and SHIFT keys simultaneously to reach Access Level 2. The display display will now read: 3. Use the UP/DOWN arrow keys to select the program parameter for change. 4. Press the SHIFT key. The program number will blink indicating that that the data value may be changed. 5. Use the UP/DOWN arrow keys to select the new data code. 6. Press the ENTER key. The display will indicate **STORED** for one second, then revert to the normal parameter display. 7. Press the PROGram key to exit the programming mode or the UP/DOWN keys to select an new parameter for change. PROGRAM CODE SUMMARY: # Name Description Data Range Factory Setting Units Access Level Customer Setting 01 MODEL Model Number 0-65000 Note 1 --- 1 02 RVLVL Software Revision 0-640 Note 1 --- 2 03 IRAT Rated Current 2-200 Note 1 A 2 05 SERNO Serial Number 0-65000 — --- 2 06 REP Repair Date 0-65000 — --- 2 07 FLT3 Last Fault --- — --- 1 08 FLT2 2nd Fault --- — --- 2 09 FLT1 1st Fault --- — --- 2 12 FOUT Output Frequency 0-400 — Hz 1 13 VOUT Output Voltage 0-100 — % 1 14 IOUT Output Current 0-650 — A 1 15 LOAD Drive Load 0-200 — °/ % 1 16 TORQ Load Torque 0-200 — % 1 17 TEMP Inverter Temp 2-105 — C 1 18 TIME1 Total Run Time 0-65000 — h 2 19 TIME2 Power On Hours 0-65000 — h 2 21 MODE Input Mode 0-36 0 --- 1 4 24 FSEL Reference Select 0-18 0 --- 2 27 TLSEL Torque Limit Select 0-6 0 --- 2 31 FMIN Min. Frequency 0.00-400 0 Hz 1 14 32 FMAX Max. Frequency 20.00-400 60 Hz 1 70 33 F2 Preset Speed #2 - Jog 0.00-400 5 Hz 1 34 F3 Preset Speed #3 0.00-400 20 Hz 2 35 F4 Preset Speed #4 0.00-400 40 Hz 2 36 F5 Preset Speed #5 0.00-400 60 Hz 2 37 F6 Preset Speed #6 0.00-400 0 Hz 2 38 F7 Preset Speed #7 0.00-400 0 Hz 2 39 FTL Min. Frequency in Torque Limit 0.00-400 10 Hz 2 41 RSEL Ramp Selector 0-7 0 --- 2 42 ACC1 Acceleration Time #1 0.10-600 3 s 1 9 43 DEC1 Deceleration Time #1 0.10-600 3 s 1 1 44 ACC2 Acceleration Time #2 0.10-600 1 s 2 45 DEC2 Deceleration Time #2 0.10-600 1 s 2 46 DECTL Torq. Limit Response Time 0.10-30 1 s 2 47 DCBRK DC Brake Time 0-5 0.2 s 2 48 DCVLT DC Brake voltage 0-15 Note1 % 2 51 VSEL V/Hz Characteristic Selector 0-5 0 --- 2 2 52 BOOST Torque Boost 0-25 Note 1 % 1 8 53 FKNEE V/Hz Knee Frequency 26-640 60 Hz 2 75 54 SKBND Skip Fresq. Hysteresis Band 0.20-20 1 Hz 2 55 SK1 Skip Frequency #1 0.00-400 0 Hz 2 56 SK2 Skip Frequency #2 0.00-400 0 Hz 2 57 SK3 Skip Frequency #3 0.00-400 0 Hz 2 58 SK4 Skip Frequency #4 0.00-400 0 Hz 2 59 MVOLT Rated Motor Voltage 185-480 Note 1 V 2 61 LTLF Load Torq. Limit Forward 5-150 150 °/ % 2 62 LTLR Load Torq. Limit Reverse 5-150 150 °/ % 2 63 RTLF Regenerative Torq. Limit FWD 5-110 80 °/ % 2 64 RTLR Regenerative Torq. Limit REV 5-110 80 °/ % 2 65 SLIP Slip Compensation 0-10* 0 % 1 66 STAB Current Stability 0-5 2 --- 2 67 TOL Timed Overload Trip Point 0-100 0 % 2 100 68 NRST Restart Number 0-8 0 --- 2 69 DRST Restart Delay 0-60* 0 s 2 6C TOLC Timed Overload Characteristic 0-7 0 --- 2 71 METER Analog Meter Output 0-7 1 --- 1 72 ST1 Auxiliary Output #1 0-11 6 --- 2 73 ST2 Auxiliary Output #2 0-11 3 --- 2 74 ST3 Auxiliary Output #3 0-11 7 --- 2 75 STR Auxiliary Relay (Fau...
Dieses Handbuch ist für folgende Modelle:Andere Küchengeräte - HA-MKGL-100-CC (2.62 mb)
Andere Küchengeräte - HA-MKGL-100 (2.62 mb)
Andere Küchengeräte - HA-MKGL-100-CC-T (2.62 mb)
Andere Küchengeräte - HA-MKGL-60 (2.62 mb)