Hersteller: TriStar
Dateigröße: 314.32 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


If leaks occur, remove connector, clean off old Teflon tape, re-wrap with one to two additional layers of Teflon tape, and re-install connector. Fittings restrict flow. For better efficiency, use the fewest possible fittings (but at least two suction outlets). Avoid fittings that could cause an air trap. Pool and spa fittings MUST conform to the International Association of Plumbing and Mechanical Officials (IAPMO) standards. Use a non-entrapping suction fitting in pool (multiple drains) or double suction (skimmer and main drain). Electrical WARNING – Ground and bond motor before connecting to electrical power supply. Failure to ground and bond pump motor can cause serious or fatal electrical shock hazard. Do NOT ground to a gas supply line. To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on electrical connections. Ground Fault Circuit Interrupter (GFCI) tripping indicates electrical problem. If GFCI trips and won’t reset, consult electrician to inspect and repair electrical system. Fire Hazard - match supply voltage to motor nameplate voltage. Insure that the electrical supply available agrees with the motor’s voltage, phase, and cycle, and that the wire size is adequate for the HP (kW) rating and distance from the power source. NOTE - All electrical wiring MUST be performed by a licensed electrician, and MUST conform to local codes and NEC regulations. Use copper conductors only. Motor Brake Horsepower Motor Rated Horsepower Motor Electric V/A Wire Size / Breaker Full Rate Pumps HP (kW) HP (kW) Voltage Amps AWG Amps 1.13 (0.84) 0.50 (0.37) 208 -230 / 115 5.3 -4.9 / 9.8 14 10 / 15 1.39 (1.04) 0.75 (0.56) 208 -230 / 115 7.0 -6.2 / 12.4 14 10 / 15 1.85 (1.38) 1.00 (0.75) 208 -230 / 115 8.5 -7.4 / 14.8 14 / 12 15 / 20 2.40 (1.79) 1.50 (1.12) 208 -230 / 115 11.2 - 10.2 / 20.4 14 / 10 15 / 30 2.70 (2.01) 2.00 (1.49) 208 -230 11.8 - 11.0 14 15 3.60 (2.69) 3.00 (2.24) 208 -230 16.0 - 14.8 12 20 3.60 (2.69) * 3.00 (2.24) * 208 -230 / 460 * 9.6 -9.4 / 4.7 * 14 * 15 / 10 * 1.85 / 0.22 (1.38 / 0.16) 1.00 / 0.12 (0.75 / 0.09) 208 -230 8.6 -8.2 . 14 15 2.40 / 0.28 (1.79 / 0.21) 1.50 / 0.18 (1.12 / 0.13) 208 -230 11.4 - 10.4 . 14 15 2.70 / 0.33 (2.01 / 0.25) 2.00 / 0.25 (1.49 / 0.19) 208 -230 12.4 - 11.2 . 14 15 Max Rate Pumps 0.94 (0.70) 0.75 (0.56) 230 / 115 5.4 / 10.8 14 10 / 15 1.25 (0.93) 1.00 (0.75) 230 / 115 7.0 / 14.0 14 10 / 15 1.65 (1.23) 1.50 (1.12) 230 / 115 7.7 / 15.4 14 / 12 10 / 20 2.20 (1.64) 2.00 (1.49) 230 / 115 10.8 / 21.6 14 / 10 15 / 30 2.60 (1.94) 2.50 (1.86) 230 11.5 14 15 3.45 (2.57) 3.00 (2.24) 230 13.5 14 15 1.85 / 0.22 (1.38 / 0.16) 1.50 / 0.18 (1.12 / 0.13) 208 -230 8.6 -8.2 . 14 15 2.40 / 0.28 (1.79 / 0.21) 2.00 / 0.25 (1.49 / 0.19) 208 -230 11.4 - 10.4 . 14 15 2.70 / 0.33 (2.01 / 0.25) 2.50 / 0.31 (1.86 / 0.23) 208 -230 12.4 - 11.2 . 14 15 ., ., . Low Speed Amps: (. 2.8 - 3.0) (. 3.2 -3.4) (. 3.8 - 4.1) * Three-Phase (3.) Pump - motor starter required WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar™ Pump Series __________ _____ _______________________________ Page 7 of 15 Electrical (cont’d.) Voltage Voltage at motor MUST NOT be more than 10% above or below motor name plate rated voltage, or motor may overheat, causing overload tripping and reduced component life. If voltage is less than 90% or more than 110% of rated voltage when motor is running at full load, consult power company. Grounding And Bonding Install, ground, bond, and wire motor in accordance with local or national electrical code requirements. Permanently ground motor. Use green ground terminal provided under motor canopy or access place; use size and type wire required by code. Connect motor ground terminal to electrical service ground. Bond motor to pool structure. Bonding will connect all metal parts within and around the pool with a continuous wire. Bonding reduces the risk of a current passing between bonded metal objects, which could potentially cause electrical shock if grounded or shorted. Reference NEC codes for all wiring standards incl...

Dieses Handbuch ist für folgende Modelle:
Pumps - SP3007EEAZ (314.32 kb)
Pumps - SP3007X10AZ (314.32 kb)
Pumps - SP3010EEAZ (314.32 kb)
Pumps - SP3010X15AZ (314.32 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien