Anleitung Zusammenfassung


No. Part No. Description Ctn. Qty. 12 SPX3205C Impeller for . HP with Impeller Screw 10 SPX3207C Impeller for . HP with Impeller Screw 10 SPX3207CM Impeller for 1 HP with Impeller Screw (Max Rate) 10 SPX3210C Impeller for 1 HP with Impeller Screw (Full Rate) 10 SPX3215C Impeller for 1 . HP with Impeller Screw 10 SPX3220C Impeller for 2 HP with Impeller Screw 10 SPX3230C Impeller for 3 HP with Impeller Screw 10 13 SPX3200SA Shaft Seal Assembly 10 14 SPX3200T Housing O-Ring 10 15 SPX3200E Seal Plate 1 16 SPX3200Z211 Housing Insert/Seal Plate Spacer Kit 1 17 SPX3200Z3 Housing Bolt 10 18 SPX3200Z5 Motor Bolt 1 19 SPX4000FG Drain Plug with O-Ring 10 20 SPX3200GA Bracket, Motor Support, TriStar 1 21 * SPX3200WF Base, Short Riser, TriStar 1 22 * SPX3200SR Base, Tall Riser, TriStar 1 Pump SKU Detail Model P/N Motor P/N Power End P/N Impeller P/N Full Rate Pumps SP3205EE SPX3205Z1BER SPX3205Z1PE SPX3205C SP3207EE SPX3207Z1BER SPX3207Z1PE SPX3207C SP3210EE SPX3210Z1BER SPX3210Z1PE SPX3210C SP3215EE SPX3215Z1BER SPX3215Z1PE SPX3215C SP3220EE SPX3220Z1BER SPX3220Z1PE SPX3220C SP3230EE SPX3230Z1BER SPX3230Z1PE SPX3230C SP32102EE SPX3210Z2BER SPX3210Z2PE SPX3210C SP32152EE SPX3215Z2BER SPX3215Z2PE SPX3215C SP32202EE SPX3220Z2BER SPX3220Z2PE SPX3220C SP323063 SPX3230Z1DR SPX3230Z1PE3 SPX3230C Max Rate Pumps SP3205X7 SPX3205Z1MR SPX3205X7Z1PE SPX3205C SP3207X10 SPX3207Z1MR SPX3207X10Z1PE SPX3207CM SP3210X15 SPX3210Z1MR SPX3210X15Z1PE SPX3210C SP3215X20 SPX3215Z1MR SPX3215X20Z1PE SPX3215C SP3220X25 SPX3220Z1MR SPX3220X25Z1PE SPX3220C SP3225X30 SPX3225Z1MR SPX3225X30Z1PE SPX3230C SP3210X152 SPX3210Z2MER SPX3210X15Z2PE SPX3210C SP3215X202 SPX3215Z2MER SPX3215X20Z2PE SPX3215C SP3220X252 SPX3220Z2MER SPX3220X25Z2PE SPX3220C NOTE – Power end assembly includes parts #7-18 and motor. * STA-RITE is a registered trademark of Sta-Rite Industries, Inc. and WHISPERFLO is a registered trademark of Pentair Water Pool & Spa, Inc., which are used herein for identification purposes only. These are retrofit bases for existing STA-RITE and WHISPERFLO pump installations. Sta-Rite Industries, Inc. and Pentair Water Pool & Spa, Inc. are not affiliated with Hayward Pool Products. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar™ Pump Series ____________________Page 13 of 15 Troubleshooting Motor Will NOT Start – Check For: Make sure the terminal board connections agree with the wiring diagram on motor data plate label. Be sure motor is wired for available field supply voltage (see pump operating label). 1. Improper or loose wiring connections; open switches or relays; tripped circuit breakers, GFCI’s, or blown fuses. Solution: Check all connections, circuit breakers, and fuses. Reset tripped breakers or replace blown fuses. 2. Manually check rotation of motor shaft for free movement and lack of obstruction. Solution: Refer to Steps 4 & 5 of “Shaft Seal Change Instructions” in this manual. 3. If you have a timer, be certain it is working properly. Bypass it if necessary. Motor Shuts OFF – Check For: 1. Low voltage at motor or power drop (frequently caused by undersized wiring or extension cord use). Solution: Contact qualified professional to check that the wiring gauge is heavy enough. NOTE: Your Hayward pump motor is equipped with an “automatic thermal overload protector.” The motor will automatically shut off if power supply drops before heat damage can build up causing windings to burn out. The “thermal overload protector” will allow the motor to automatically restart once the motor has cooled. It will continue to cut On/Off until the problem is corrected. Be sure to correct cause of overheating. Motor Hums, But Does NOT Start – Check For: 1. Impeller jammed with debris. Solution: Have a qualified repair professional open the pump and remove the debris. Pump Won't Prime, Check For: 1. Empty pump/strainer housing. Solution: Make sure pump/strainer housing is filled with water and cover o-ring is clean. Ensure o-ring is properly seated in the cover o-ring groove. Ensure o-ring sealing surface is lubrica...

Dieses Handbuch ist für folgende Modelle:
Pumps - SP3007EEAZ (314.32 kb)
Pumps - SP3007X10AZ (314.32 kb)
Pumps - SP3010EEAZ (314.32 kb)
Pumps - SP3010X15AZ (314.32 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien