Login:
Stimmen - 3, Durchschnittliche Bewertung: 5 ( )

Anleitung Campbell Hausfeld, modell CE8000

Hersteller: Campbell Hausfeld
Dateigröße: 8.42 mb
Dateiname:
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Refer to motor name plate for electrical ratings and specifications. 3. The line wire is the proper size and that no other equipment is operated from the same line. The chart gives minimum recommended wire sizes for compressor installations. MiniMuM pipe Size for CoMpreSSed Air line CfM length of piping System 25 feet 50 feet 100 feet 250 feet 10 20 40 60 100 1/2 inch 3/4 inch 3/4 inch 3/4 inch 1 inch 1/2 inch 3/4 inch 1 inch 1 inch 1 inch 3/4 inch 3/4 inch 1 inch 1 inch 1 inch 3/4 inch 1 inch 1 inch 1 inch 1-1/4 inch figure 5 - Shut-off valve MiniMuM Wire Size (uSe 75°C Copper Wire) Make sure voltage is correct with the motor wiring. NOTE: If using 208 volts single phase, make sure the motor name plate states it is rated for 208 volts single phase. 230 volt single phase motors do not work on 208 volts unless they have the 208 volt rating. Single phase three phase Hp AMpS 230v 208/230v 460/575v SPL 5.0 7.5 10.0 15.0 25.0 UP TO 22.0 10 AWG 8 AWG 8 AWG N/A N/A N/A 12 AWG 14 AWG 10 AWG 12 AWG 8 AWG 12 AWG 6 AWG 10 AWG 3 AWG 8 AWG Recommended wire sizes may be larger than the minimum set up by local ordinances. If so, the larger size wire should be used to prevent excessive line voltage drop. The additional wire cost is very small compared with the cost of repairing or replacing a motor electrically “starved” by the use of supply wires which are too small. Operating Instructions Installation (Continued) L1 Pressure Switch Thermal Unit (1) L2 Circuit Breaker or Fused Disconnect Motor Over Load Coil T2T1 X2 L1 L2 Pressure Switch Thermal Units (3) L3 T2 Circuit Breaker or Fused Disconnect X2 Motor Over Load Coil T3T1 figure 6 - Single phase Wiring diagram figure 7 - three phase Wiring diagram T1 Load Over X2 Circuit Breaker or Fused Disconnect T2 Switch Pressure L2L1 GROUND SCREW *CUSTOMER INSTALLED POWER SUPPLY Motor Units(2) Thermal Coil 120V LOW-OIL SWITCH *MAIN DISCONNECT BRANCH CIRCUIT PROTECTION TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL AND LOCAL CODES. CUSTOMER INSTALLED CONTROL POWER SUPPLY 120V T1 Load Over X2 Circuit Breaker or Fused Disconnect T2 Switch Pressure L2L1 GROUND SCREW *CUSTOMER INSTALLED POWER SUPPLY Motor Units(3) Thermal Coil 120V LOW-OIL SWITCH CUSTOMER INSTALLED CONTROL POWER SUPPLY 120V T3 L3 *MAIN DISCONNECT BRANCH CIRCUIT PROTECTION TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL AND LOCAL CODES. figure 8 -Single phase wiring diagram - Automotive Series figure 9 - three phase wiring diagram - Automotive Series (fully packaged) Models (fully packaged) Models Installation (Continued) GroundinG Improperly grounded electrical components are shock hazards. Make sure all the components are properly grounded to prevent death or serious injury. This product must be grounded. Grounding reduces the risk of electrical shock by providing an escape wire for the electric current if short circuit occurs. This product must be installed and operated with a power cord or cable that has a grounding wire. BreAkerS And fuSeS The entire electrical system should be checked by a certified electrician. Time delay breakers and fuses are required for this compressor. A tripped breaker or blown fuses may indicate a direct short to ground, high current draw, improper wiring, incorrect fuse or breaker size and/or type. This needs to be evaluated by a certified electrician. Motor Hookup And StArter inStAllAtion Branch circuit protection must be provided as specified in the United States National Electrical Code, Chapter 2, “Wiring Design and Protection.” Article 210, using the applicable article “For Motors and Motor Controllers,” (Article 430, Table 430-1 52). IMPORTANT: Overload protection is required for all motors. Motors used on CE7000, CE8000 and CE9000 Series air compressors do not have built-in overload protection. A magnetic starter is required. All CE Series compressors, except models CE8000 and CE8002, include a magnetic starter. Refer to the following wiring diagrams for electrical installation: Shop Air Series Models -Figures 6 or 7 Automotive Series Models -Figures 8 or 9 Three phase motors are tri-voltage rated: 208-230/460. They are shipped from the factory pre-wired for 208-230 volt operation. If 460 volt operation is desired, some rewiring is required. Shop Air Series Models 1. Rewire the motor leads for 460 volt per motor data plate. 2. Install the 460 volt conversion kit provided with the unit. Both the coil and the thermal overload elements in the magnetic starter must be changed (see Figure 11). Automotive Series Models 1. Rewire the motor leads for 460 volt per motor data plate. 2. Install the three thermal overload elements provided in the conversion kit (see Figure 12). The coil in the Automotive Series models operates on 120 volts and does not have to be changed. Grounded Outlet Grounding Pin figure 10 - Grounding figure 11 - 460 volt Conversion kit - Shop Air Series figure 12 - 460 volt Convers...

Dieses Handbuch ist für folgende Modelle:
Pumps - CE7000 (8.42 mb)
Pumps - CE9000 (8.42 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien