Anleitung Zusammenfassung


The incoming wires and the compressor electrical connections should be checked. Loose connections will cause malfunctions. Unit does not make any or very little air Drain valve open Air leak Restricted or blocked intake Make sure the drain valve at the bottom of the tank is closed. Check the entire system for leaks, including the compressor unit and any piping attached to the compressor Make sure that the air intake of the compressor is not blocked in any way. Continued on next page 15 Operating Instructions Troubleshooting Guide for New Installations (Continued) SyMptoM CAuSe Solution Unit runs very noisy Damage to the compressor Check to make sure the compressor has not been damaged in the shipping or installation. Make sure the belt guard was not damaged. Belt guard should not be making contact with flywheel or pulley. Loose fasteners Check all bolts and nuts to assure they did not loosen during shipping. Loose flywheel or pulley Check to assure pulley and flywheel are correctly tightened. Improper installation If unit is left on skid it may cause excessive vibration. Remove unit from skid and mount loosely to floor with vibration pads and anchor bolts. Do not tighten bolts tight. Leave nut loose approximately 1/8 inch from compressor foot. Oil in discharge air or out crankcase breather Break in period Some oil in the exhaust air is normal during the break-in period and during heavy usage after the break-in period. Oil discharge should reduce as hours are accumulated on the unit. Wrong type of oil Do not use SAE-30 automotive type oil. Using the wrong oil can cause problems with the pump and will void the warranty. Only use the oils that the operating manual recommends (see Lubrication section). Improper environment Unit should not be installed in a poorly vented area or exposed to extreme cold or hot conditions. Normal operating range should be between 32°F and 100°F. Compressor seems to run hot Rotation incorrect Check to make sure the compressor is running the direction of the flywheel arrow. Air flow should be so that the flywheel directs air across the head of the pump. Standing in front of the compressor (non-belt guard side) air should flow back to front. 16 Series CE7000, CE8000 and CE9000 Troubleshooting Guide for Units in Service for a Period of Time SyMptoM CAuSe Solution Motor does not run Motor hums; motor draws high amps, trips overload, trips breaker, or blows fuse on start up Loose electrical connections Blown fuse and/or tripped breaker Starter overload tripped Defective capacitor Defective magnetic starter Defective pressure switch unloader Defective check valve constant loss of tank pressure Loose electrical connections Defective capacitor Valve problem or blown gasket The entire electrical system should be checked by a certified electrician. The incoming wires and the compressor electrical connections should be checked. Loose connections will cause malfunctions. The breaker and fuses required for this unit must be time delay. A tripped breaker or blown fuse may result from a direct short to ground, high current draw, improper wiring, incorrect fuse or breaker size and/or type. This needs to be evaluated by a service center or certified electrician. Check and reset if necessary. If the overload trips after the initial reset, refer to the section of the manual that covers this issue. Check and replace (if necessary) defective capacitor. First check for any loose wiring and tighten if loose. Check and replace (if necessary) defective magnetic starter. Drain the tank of all pressure. Restart compressor under no load. If compressor is able to start, then the unloader needs to be checked. If this problem is not corrected it will fail the motor and / or other electrical components. Determine if the check valve is working properly -pressure switch unloader should quit hissing after the compressor shuts off. If the hissing continues and if there is a constant loss of tank pressure, then the check valve is not working properly. Replace check valve. The entire electrical system should be checked by a certified electrician. The incoming wires and the compressor electrical connections should be checked. Loose connections will cause malfunctions. Check and replace (if necessary) defective capacitor. Check gasket and replace as needed. Other symptoms occur when a valve is not sealing or a gasket is blown such as higher than normal amp draw which may trip out the overload or breaker. Compressor runs but builds pressure slowly Air leak Dirty air filter Valve problem or blown gasket Tank cracked Check the entire system for leaks, including the compressor unit and any piping attached to the compressor Air filters need to be changed regularly based on usage and environment. A dirty filter may appear to be clean. Change filters often. Check gasket and replace as needed. Other symptoms occur when a valve is not sealing or a gasket is blown such as higher than nor...

Dieses Handbuch ist für folgende Modelle:
Pumps - CE7000 (8.42 mb)
Pumps - CE8000 (8.42 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien