Anleitung Fisher & Paykel, modell 87641
Hersteller: Fisher & Paykel Dateigröße: 827.25 kb Dateiname: 103600D_rh_uc.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
If t' rangehood is to be installed as ducted unit, remove the duct knock-out (top or ensure the vent cover is in place. Refer also to Ducting Options. OPERATION After your Rangehood is fixed in position: 1. Check that the light and the diffuser are in place. 2. See that the filters are correctly positioned. 3. Plug into 230/240V 3 pin outlet. Keep cord clear of stove elements or hot utensils. Permanent wiring to house supply, or modifications to plug or wire should be carried out by a registered electrician. CLEANING 1. Disconnect the Rangehood from power supply. 2. Wash aluminium filters every 2 or 3 months, depending on usage, with hot soapy water or in the dishwasher. 3. Charcoal filters are disposable items and should be replaced when cleaning the rangehood. 4. Clean the external and internal surfaces including the fan blades, using a damp cloth and mild detergent. Do not use any powder or abrasive cleaners. 5. In high humidity and coastal environments, cleaning should be carried out frequently. LAMP REPLACEMENT 1. Disconnect the Rangehood from power supply. 2. Insert small screwdriver or slim knife as shown, ease catch to side and slip out the diffuser. 3. Replace lamp (40 watt max). 4. Slide diffuser back into aperture and ‘click’ into place. PARTS AND SERVICE For Accessories, Parts or Services, please contact your local supplier or approved service agent. (Refer to the Warranty Certificate) WARNING •This appliance is not intended for use by young children or infirm persons without supervision. •Young children should be supervised to ensure that they do not play with the appliance. • There shall be adequate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels. • You must read the details concerning the method and frequency of cleaning. • There is a fire risk if cleaning is not carried out in accordance with the instructions. •Do not flambé under the range hood. • Exhaust air must not be discharged into an existing flue which is used for exhausting fumes from appliances burning gas or other fuels. • The minimum distance between the hob surface and the lowest part of the range hood is 600mm. This distance shall be at least 650mm if the range hood is installed over a gas hob. •That regulations concerning the discharge of exhaust air have to be fulfilled. • If the supply cord of this equipment is damaged, it must only be replaced by the manufacturer or its service agent or similarly qualified person in order to avoid a hazard. Fisher & Pavkel INSTALLATION INSTRUCTIONS MODELS 87641,87642,87643 87644,87645,87646 To be used together with mounting instructions WALL MOUNTING 600mm and 900mm sizes For mounting with rear rectangular ducts on internal walls cut hole to dimensions shown (UNIDUCT ONLY) For external walls cut hole 90 x 290mm (UNIDUCT ONLY) 820 î II 600 MODEL Electrical Rating: 280W (1.16A) Max. at 240V 50Hz 2.4m CEILING HEIGHT 600 • 803mm For Gas 650 - 800mm For stainless steel models ensure the plastic protective covering is removed before installation. 103600 Issue “D” 152 UNDERCUPBOARD MOUNTING Model 600 500 Underside View of Cupboard For top ducting cut hoto to suit duct size. Dimensions shown are for Uniduct + 290 MOUNTING OPTIONS UNDERCUPBOARD MOUNTING Model 900 820 □ Underside 73 View of 2 Cupboard -f For top ducting cut hole to suit duct size. Dimensions shown are for ^ Uniduct 290 DUCTING OPTIONS RECIRCULATING REAR DUCTED FLEXIBLE DUCT FOR SIDE DUCTING TOP DUCTED THROUGH ROOF ATTACI- \ VENT COVER ATTAC H VENT COVER NOTE: when ducting Exhaust air must not be discharged into any chimney or flue which may carry combustion products from other sources. In addition, exhaust air must not be discharged into a wall cavity, unless designed for the purpose. MOUNTING TO REAR WALL MOUNTING UNDER CUPBOARDS NOTE: Fastening screws and plugs are not supplied due to the various types and thickness of fixing surfaces available. Contact your local hardware outlet. WALL MOUNTING DETAILS FOR INSTALLATION OF PLUGS FOR WALL MOUNTING 1. Mark location of holes as per installation instructions. 2. Drill hole. Note: Do not use a screw driver to punch a hole in the base material. 3. Insert Plastic Toggle and tap with a hammer to ensure it is flush with the base material. NOT FOR USE IN SOLID WALLS 103600 Issue “D” FOR SOLID WALLS USE APPROPRIATE WALL PLUGS...