|
Anleitung Zusammenfassung
If the motor should overheat, the overload protector will shut the motor off. When the temperature returns to normal, the motor will restart automatically. NOTICE! Do not stop the compressor by pulling out the plug. Use only the On/Off switch, which operates a pressure relief valve on the compressor. If the compressor is plugged in with the switch in the “On” position, the compressor may have trouble restarting against the high pressure which could cause excessive heat build up and could damage the motor. Safety Valve: This compressor is equipped with a safety valve that is set to avoid over-pressurization of the air tanks. This valve is factory pre-set at 160 PSI and will not function unless tank pressure reaches this pressure. DO NOT ATTEMPT TO ADJUST OR ELIMINATE THIS SAFETY DEVICE. ANY ADJUSTMENTS TO THIS VALVE COULD CAUSE SERIOUS INJURY. If this device requires service or maintenance, see an Authorized BOSTITCH Service Center. 5 ELECTRICAL GROUNDING INSTRUCTIONS: (continued) DUTY CYCLE: To ensure long life of your BOSTITCH air compressor, do not operate on more than a 50% duty cycle. If this air compressor pumps air more than 50% of one hour, then the compressor’s capability is less than the air delivery required by the application. Always match the air volume requirements of the attachment or accessory with the air volume delivery of the compressor. Notice!: BOSTITCH does not recommend the use of extension cords with compressors. The use of an extension cord can result in the loss of voltage supplied to the compressor which could prevent the compressor from starting. For optimum performance, plug the compressor directly into an outlet and increase the length of airline as needed. If an extension cord must be used, use these guidelines: Distance Needed Recommended Gauge Less than 25 ft. 12 Gauge 25 - 50 ft. 10 Gauge Greater than 50 ft. Not Recommended CAP2000P-OF SPECIFICATIONS Motor: 2HP (Peak) / 1.5HP (Running) 115V – 60HZ Fuse Requirements: 15 Amps minimum Operating Pressure: 0 – 150PSI Safety Valve Setting: 160 PSI Air Delivery: 3.7 CFM @ 40 PSI 2.8 CFM @ 90 PSI Maximum Amps at Working Pressure: 12 Tank Size: 6 Gallons Air Outlet: 1/4" NPT Pressure Switch Settings: On @ 120 PSI Off @ 150 PSI Weight: 37lbs. PSI = Pounds Per Square Inch: CFM = Cubic Feet Per Minute 6 FEATURES OF THE BOSTITCH CAP2000P-OF A B D E A. Pressure Switch: -The pressure switch is the activation mechanism that is used to start and stop the compressor. When the switch is pulled out to the “On” position, the motor and pump will compress air until tank pressure reaches the upper limit of the factory set operating pressure. When tank pressure falls below the factory set “cut in” pressure, the compressor will again C automatically start to compress air. B. Tank Pressure Gauge: The tank pressure gauge indicates the air pressure that is present in the tank in PSI (lbs/sq. in.). C. Regulated Pressure Gauge: The regulated pressure gauge indicates the amount of pressure that is allowed into the discharge line according to the setting of the regulator. D. Regulator Knob: The regulator knob is used to adjust the air pressure that is available at the discharge line. The discharge air pressure is increased by turning the knob clockwise and decreased by turning the knob counter clockwise. E. Drain Cock: Twist style valve that drains moisture from the tank when opened. 7 OPERATION INSTRUCTIONS Pre-Start Procedures: 1. Inspect the compressor for any damaged components. Do not operate if compressor is damaged. 2. Verify that the tanks have been drained and are clear of any moisture or dirt (See “Draining Tank”). Start-Up Procedures: 1. Verify that the On/Off switch is in the Off position. 2. Verify that the tank air pressure is at 0 PSI. 3. Attach the air hose to the discharge line. 4. Plug the unit into a properly grounded outlet. 5. Pull out the On/Off switch to On. The compressor will automatically cycle on and off to keep the tank pressure maintained . 6. Adjust the pressure regulator to the proper pressure setting required for the air tool. Shut-Off Procedures: 1. Push in the On/Off switch to the Off position. GENERAL MAINTENANCE Service and Maintenance: Prior to performing service and maintenance to the compressor, always disconnect all accessories and attachments from the unit, and disconnect the compressor from the electrical source. When replacing parts, only use Genuine BOSTITCH replacement parts. Notice!: This compressor is equipped with an oil-free pump. There is no oil to replace or check. Draining Tank - Twist-Style Drain Cocks: 1. Verify that the compressor is turned Off. 2. Holding the handle, tilt the compressor toward the drain cock so that they are positioned at the bottom of the tank. 3. Turn the drain cock to open the valve. 4. Keep the compressor tilted until all moisture has been removed. ANY OTHER SERVICE SHOULD ONLY BE PERFORMED BY AN AUTHORIZED BOSTITCH SERVICE CENTER 8 LIMITED WARRANTY Bostitch, Inc., warrants to the ...
Dieses Handbuch ist für folgende Modelle:Pumps - CAP2000P-OF (192.13 kb)