|
Dieses Gerät hat auch andere Anweisungen:
Anleitung Zusammenfassung
The data will be echoed when [Parameter change ECHO] is on. The corresponding parameter will be changed immediately the data is received. Transmission Data will be transmitted with the [Device Number] in [Tx CH] when [Parameter change Tx] is on and the parameter is not registered on the [control change assign table]. STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture’s ID number (YAMAHA) SUB STATUS 0001nnnn 1n n=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3E Digital mixer MODEL ID 00010001 11 M7CL DATA 0ccccccc cc Category DATA 0eeeeeee ee Element no. 0eeeeeee ee Element no. 0iiiiiii ii Index no. 0iiiiiii ii Index no. 0ccccccc cc Channel no. 0ccccccc cc Channel no. 0ddddddd dd data : : EOX 11110111 F7 End of exclusive 4.1.2 Format (Parameter request) Receive Data will be received when [Parameter change Rx] is on and the Device number of both [Rx CH] and SUB STATUS are matched. The data will be echoed when [Parameter change ECHO] is on. The corresponding parameter will be changed via ParameterChange immediately the data is received. STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture’s ID number (YAMAHA) SUB STATUS 0001nnnn 3n n=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3E Digital mixer MODEL ID 00010001 11 M7CL DATA Category 0ccccccc cc DATA 0eeeeeee ee Element no. 0eeeeeee ee Element no. 0iiiiiii ii Index no. 0iiiiiii ii Index no. 0ccccccc cc Channel no. 0ccccccc cc Channel no. EOX 11110111 F7 End of exclusive 4.1.3 Data category DATA CATEGORY NAME 0x01 00000001 Current Scene/Setup/Backup/ User Setup Data 4.2 Function call – library store, recall – 4.2.1 Format (Parameter change) Receive Data will be received when [Parameter change Rx] is on and the Device number of both [Rx CH] and SUB STATUS are matched. The data will be echoed when [Parameter change ECHO] is on. The corresponding parameter will be changed immediately the data is received. Transmission Data will be transmitted with the [Device Number] in [Tx CH] when [Parameter change Tx] is on. STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture’s ID number (YAMAHA) SUB STATUS 0001nnnn 1n n=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3E Digital mixer MODEL ID 00010001 11 M7CL DATA CATEGORY 00000000 00 OTHER DATA FUNCTION NAME 01001100 "L"(ASCII CODE) 01101001 "i"(ASCII CODE) 01100010 "b"(ASCII CODE) 0fffffff ff (ASCII CODE) 0fffffff ff (ASCII CODE) 0fffffff ff (ASCII CODE) 0fffffff ff (ASCII CODE) 0fffffff ff (ASCII CODE) MODULE NAME 0mmmmmmm mm (ASCII CODE) 0mmmmmmm mm (ASCII CODE) 0mmmmmmm mm (ASCII CODE) 0mmmmmmm mm (ASCII CODE) 0mmmmmmm mm (ASCII CODE) 0mmmmmmm mm (ASCII CODE) 0mmmmmmm mm (ASCII CODE) 0mmmmmmm mm (ASCII CODE) DATA 0mmmmmmm mh number High 0mmmmmmm ml number Low 0ccccccc ch channel High 0ccccccc cl channel Low EOX 11110111 F7 End of exclusive Apendices 257 M7CL Manual de instrucciones Formato de datos MIDI Formato de datos MIDI 2 Function Name FUNCTION NAME Store Recall Unknown Factor Store Unknown Factor Recall Store Undo (only Scene) Recall Undo (only Scene) 4.2.3 Module Name MODULE NAME Scene Input EQ Output EQ Dynamics GEQ Effect Function Number channel*1) tx/rx “LibStr__“ SCENE 1- 300 *5) tx/rx INPUT EQ LIB 41- 199 *1) tx/rx OUTPUT EQ LIB 4- 199 *2) *3) *4) tx/rx Dynamics LIB 42- 199 *1) *2) *3) *4) *8) tx/rx GEQ LIB 1- 199 *6) tx/rx EFFECT LIB 58- 199 *7) tx/rx “LibUnStr“ SCENE 1- 300 0 tx INPUT EQ LIB 41- 199 0 tx OUTPUT EQ LIB 4- 199 0 tx Dynamics LIB 42- 199 0 tx GEQ LIB 1- 199 0 tx EFFECT LIB 58- 199 0 tx “LibRcl__“ SCENE 0- 300 *5) tx/rx INPUT EQ LIB 1- 199 *1) tx/rx OUTPUT EQ LIB 1- 199 *2) *3) *4) tx/rx Dynamics LIB 1- 199 *1) *2) *3) *4) *8) tx/rx GEQ LIB 0- 199 *6) tx/rx EFFECT LIB 1- 199 *7) tx/rx “LibUnRcl“ SCENE 0 *5) tx INPUT EQ LIB 0 *1) tx OUTPUT EQ LIB 0 *2) *3) *4) tx Dynamics LIB 0 *1) *2) *3) *4) *8) tx GEQ LIB 0 *6) tx EFFECT LIB 0 *7) tx “LibStrUd“ SCENE 0 0 “LibRclUd“ SCENE 0 0 *1) 0:CH1–47:CH48 48:ST IN 1L–55:ST IN 4R *2) 256:MIX1–271:MIX16 *3) 512:MATRIX1–519:MATRIX8 *4) 1024:STEREO L–1026:MONO(C) *5) 512:will be used if the recalling or storing data is only one. *6) 0:RACK1–7:RACK8 If a GEQ is mounted in RACK 1–8. *7) 0:RACK5–3:RACK8 If an effect is mounted in RACK 5–8. *8) 1280:CH 1–1327:CH 48 1328:STIN 1L–1335:STIN 4R (Dynamics2) “LibStr__” “LibRcl__” “LibUnStr” “LibUnRcl” “LibStrUd” “LibRclUd” “SCENE___” “INEQ____” “OUTEQ___” “DYNA____” “GEQ_____” “EFFECT__” 4.3 Function call – library edit – 4.3.1 Format (Parameter change) Receive Data will be received when [Parameter change Rx] is on and the Device number of both [Rx CH] and SUB STATUS are matched. The data will be echoed when [Parameter change ECHO] is on. The corresponding memory/library will be changed immediately the data is received. Transmission Parameter Change Message will be sent in reply to Request. If [Parameter change ECHO] is on, the message will be sent as it is. STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture’s ID...
Dieses Handbuch ist für folgende Modelle:Musikinstrumente - M7CL-32 (10.84 mb)
Musikinstrumente - M7CL-48ES (10.84 mb)