Login:
Stimmen - 2, Durchschnittliche Bewertung: 5 ( )

Anleitung Yamaha, modell M7CL-48

Hersteller: Yamaha
Dateigröße: 13.09 mb
Dateiname:
Unterrichtssprache:enesca
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:

Anleitung Zusammenfassung


Reception These messages are echoed to MIDI OUT if [Control Change ECHO] is ON. If [TABLE] is selected, these messages are received when [Control Change Rx] is ON and [Rx CH] matches, and will control parameters according to the settings of the [Control assign table]. For the parameters that can be assigned, refer to “Parametros que se pueden asignar para controlar los cambios” on page 270. If [NRPN] is selected, these messages are received when [Control Change Rx] is ON and the [Rx CH] matches; the four messages NRPN control number (62h, 63h) and DATA ENTRY control number (06h, 26h) are used to control the specified parameter. Transmission If [TABLE] is selected, and if [Control Change Tx] is ON when you operate a parameter that is assigned in the [Control assign table], these messages will be transmitted on the [Tx CH] channel. For the parameters that can be assigned, refer to “Parametros que se pueden asignar para controlar los cambios” on page 270. If [NRPN] is selected, and if [Control Change Tx] is ON when you operate a specified parameter, the four messages NRPN control number (62h, 63h) and DATA ENTRY control number (06h, 26h) are transmitted on the [Tx CH] channel. For the parameters that can be assigned, refer to “Parametros que se pueden asignar para controlar los cambios” on page 270. Control Change messages are not used for transmission to M7CL Editor because there is no guarantee that the contents of the assignment tables will match. (Parameter Change messages are always used.) Control Change numbers 0 and 32 are for selecting banks. STATUS 1011nnnn Bn Control change DATA 00 Control number (00) 0vvvvvvv vv Control Value (0-127) STATUS 1011nnnn Bn Control change DATA 20 Control number (32) 0vvvvvvv vv Control Value (0-127) If [TABLE] is selected STATUS 1011nnnn Bn Control change DATA 0nnnnnnn nn Control number (1-5, 7-31, 33-37, 38-95, 102-119) * 0vvvvvvv vv Control Value (0-127) * Numbers 0, 32, and 96–101 cannot be used. * Control number 6, 38 can be used. Equation for converting a Control Value to parameter data paramSteps = paramMax - paramMin + 1; add = paramWidth / paramSteps; mod = paramWidth - add * paramSteps; curValue = paramSteps * add + mod / 2; (1) If the assigned parameter has fewer than 128 steps paramWidth = 128; rxValue = Control value; (2) If the assigned parameter has 128 or more but less than 16,384 steps paramWidth = 16384; (2-1) When High and Low data is received rxValue = Control value(High) * 128 + Control value(Low); (2-2) When only Low data is received rxValue = (curValue & 16256) + Control value(Low); (2-3) When only High data is received rxValue = Control value(High) * 128 + (curValue & 127); (3) If the assigned parameter has 16,384 or more but less than 2,097,152 steps paramWidth = 2097152; (3-1) When High, Middle, and Low data is received rxValue = Control value(High) * 16384 + Control value(Middle) * 128 + Control value(Low); (3-2) When only Low data is received rxValue = (curValue & 2097024) + Control value(Low); (3-3) When only Middle data is received rxValue = (curValue & 2080895) + Control value(Middle) * 128; (3-4) When only High data is received rxValue = (curValue & 16383) + Control value(High) * 16384; (3-5) When only Middle and Low data is received rxValue = (curValue & 2080768) + Control value(Middle) * 128 + Control value(Low); (3-6) When only High and Low data is received rxValue = (curValue & 16256) + Control value(High) * 16384 + Control value(Low); (3-7) When only High and Middle data is received rxValue = (curValue & 127) + Control value(High) * 16384 + Control value(Middle) * 128; if ( rxValue > paramWidth) rxValue = paramWidth; param = ( rxValue - mod / 2) / add; If [NRPN] is selected STATUS 1011nnnn Bn Control change DATA 01100010 62 NRPN LSB 0vvvvvvv vv Parameter number LSB STATUS 1011nnnn Bn Control change * DATA 01100011 63 NRPN MSB 0vvvvvvv vv Parameter number MSB STATUS 1011nnnn Bn Control change * DATA 00000110 06 Data entry MSB 0vvvvvvv vv Parameter data MSB STATUS 1011nnnn Bn Control change * DATA 00100110 26 Data entry LSB 0vvvvvvv vv Parameter data LSB * The STATUS byte of the second and subsequent messages need not be added during transmission. Reception must occur correctly whether or not the status byte is omitted. M7CL Manual de instrucciones Formato de datos MIDI Formato de datos MIDI PROGRAM CHANGE (Cn) Reception If [Program Change ECHO] is ON, bank select messages will also be echoed from MIDI OUT. If SINGLE CH is selected, these messages are received if [Program Change RX] is ON and the [Rx CH] matches. However if [OMNI] is ON, these messages are received regardless of the channel. When these messages are received, scene memory and effect library are recalled according to the settings of the [Program Change Table]. Transmission If [Program Change TX] is ON, these messages are transmitted according to the [Program Change Table] settings when scene memory and effect library are recalled. If SINGLE CH is selected, these messages a...

Dieses Handbuch ist für folgende Modelle:
Musikinstrumente - M7CL-32 (13.09 mb)
Musikinstrumente - M7CL-48ES (13.09 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien