Login:
Stimmen - 4, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Yamaha, modell M7CL-32

Hersteller: Yamaha
Dateigröße: 11.64 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:

Anleitung Zusammenfassung


This means that the limiter’s output level never actually exceeds the threshold. Parameter Range Description THRESHOLD (dB) –54 to 0 (55 points) This determines the level of input signal required to trigger the compressor. RATIO 1.0:1, 1.1:1, 1.3:1, 1.5:1, 1.7:1, 2.0:1, 2.5:1, 3.0:1, 3.5:1, 4.0:1, 5.0:1, 6.0:1, 8.0:1, 10:1, 20:1, .:1 (16 points) This determines the amount of compression, that is, the change in output signal level relative to change in input signal level. ATTACK (ms) 0–120 (121 points) This determines how soon the signal will be compressed once the compressor has been triggered. RELEASE (ms) 44.1kHz: 6 ms – 46.0 sec 48kHz: 5 ms – 42.3 sec (160 points) This determines how soon the compressor returns to its normal gain once the trigger signal level drops below the threshold. The value is expressed as the duration required for the level to change by 6 dB. OUT GAIN (dB) 0.0 to +18.0 (181 points) This sets the compressor’s output signal level. KNEE Hard, 1–5 (6 points) This determines how compression is applied at the threshold. For higher knee settings, compression is applied gradually as the signal exceeds the specified threshold, creating a more natural sound. • I/O Characteristics • Time Series Analysis (RATIO= .:1) (KNEE= hard, OUT GAIN=0.0dB) Input Level Time Time Output LevelInput LevelOutput LevelRATIO THRESHOLD THRESHOLD Input signal Output Signal ATTACK RELEASE ¦ EXPANDER An expander attenuates signals below a specified THRESHOLD by a specified RATIO. Parameter Range Description THRESHOLD (dB) –54 to 0 (55 points) This determines the level of input signal required to trigger the expander. RATIO 1.0:1, 1.1:1, 1.3:1, 1.5:1, 1.7:1, 2.0:1, 2.5:1, 3.0:1, 3.5:1, 4.0:1, 5.0:1, 6.0:1, 8.0:1, 10:1, 20:1, .:1 (16 points) This determines the amount of expansion. ATTACK (ms) 0–120 (121 points) This determines how soon the expander returns to its normal gain once the trigger signal level exceeds the threshold. RELEASE (ms) 44.1kHz: 6 ms – 46.0 sec 48kHz: 5 ms – 42.3 sec (160 points) This determines how soon the signal is expanded once the signal level drops below the threshold. The value is expressed as the duration required for the level to change by 6 dB. OUT GAIN (dB) 0.0 to +18.0 (181 points) This sets the expander’s output signal level. KNEE Hard, 1–5 (6 points) This determines how expansion is applied at the threshold. For higher knee settings, expansion is applied gradually as the signal falls below the specified threshold, creating a more natural sound. • I/O Characteristics • Time Series Analysis (RATIO= .:1) (KNEE= hard, OUT GAIN= 0.0dB) Input Signal Output Signal Input Level Time Time Output LevelInput LevelOutput Level THRESHOLD THRESHOLD ATTACK RELEASE RATIO M7CL Owner’s Manual Dynamics Parameters Dynamics Parameters COMPANDER HARD (COMPANDER-H), COMPANDER SOFT (COMPANDER-S) The hard and soft companders combine the effects of the compressor, expander and limiter. 0dB Input Level Output Level THRESHOLD WIDTH The companders function differently at the following levels: 10 dB and higher . . . . . . . . . . . . . . . . . . Functions as a limiter. 2Exceeding the threshold . . . . . . . . . . Functions as a compressor. 3Below the threshold and width . . . . Functions as an expander. The hard compander has an expansion ratio of 5:1, while the soft compander has an expansion ratio of 1.5:1. The expander is essentially turned off when the width is set to maximum. The compressor has a fixed knee setting of 2. * The gain is automatically adjusted according to the ratio and threshold values, and can be increased by up to 18 dB. *The OUT GAIN parameter enables you to compensate for the overall level change caused by the compression and expansion processes. Parameter Range Description THRESHOLD (dB) –54 to 0 (55 points) This determines the level at which compression is applied. RATIO 1.0:1, 1.1:1, 1.3:1, 1.5:1, 1.7:1, 2.0:1, 2.5:1, 3.0:1, 3.5:1, 4.0:1, 5.0:1, 6.0:1, 8.0:1, 10:1, 20:1 (15 points) This determines the amount of compression. ATTACK (ms) 0–120 (121 points) This determines how soon the signal is compressed or expanded once the compander has been triggered. RELEASE (ms) 44.1kHz: 6 ms – 46.0 sec 48kHz: 5 ms – 42.3 sec (160 points) This determines how soon the compressor or expander returns to the normal gain once the trigger signal level drops below or exceeds the threshold respectively. The value is expressed as the duration required for the level to change by 6 dB. OUT GAIN (dB) –18.0 to 0.0 (181 points) This sets the compander’s output signal level. WIDTH (dB) 1–90 (90 points) This determines how far below the threshold expansion will be applied. The expander is activated when the level drops below the threshold and width. ¦ DE-ESSER This detects and compresses only the sibilants and other high-frequency consonants of the vocal. Parameter Range Description THRESHOLD –54 to 0 (55 points) Threshold level at which the de-esser effect applies. FREQUENCY 1kHz – 12.5kHz (45 points) Cutoff frequ...

Dieses Handbuch ist für folgende Modelle:
Musikinstrumente - M7CL-48 (11.64 mb)
Musikinstrumente - M7CL-48ES (11.64 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien