Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung Kenwood, modell HM-383MD

Hersteller: Kenwood
Dateigröße: 1.44 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Care Wipe periodically dust and dirt attached on the cartridge with a dry cloth. Write protect tab To protect recorded contents against accidental erasure, set the write protect tab of the disc open. Return the tab to the original position when you want to record signals on the disc. Disc back side Write protect tab Slide open. Slide close. (Recording disabled) (Recording enabled) Note on the cartridge labels Apply each label firmly to every corner so that it will not be peeled off. Caution on MD-Clip data Do not attempt to record or edit a disc in which MD-Clip data (still images, etc.) have been recorded. Otherwise, the Clip data may be lost. Knowledge sections 80 In case of difficulty 80 In case of difficulty What seems to be a malfunction is not always so. Before calling for service, check the following table according to the symptom of your trouble. Operation to reset The microcomputer may fall into malfunction (impossibility to operate, erroneous display, etc.) when the power cord is unplugged while unit is ON or due to an external factor. In this case, execute the following procedure to reset the microcomputer and return it to normal condition. Unplug the power cord from the power outlet then, while holding the key depressed, plug the power cord again. . Please note that resetting the microcomputer clears the contents stored in and it returns to condition when it left the factory. Amplifier section/Speakers Symptom Remedy Sound is not produced. . Connect properly referring to "System connections". 6 . Adjust to an required volume. . Switch MUTE OFF. % . Unplug the headphone plug. The "standby/timer" indicator blinks in red and no sound is put out. . A speaker cord is short-circuited. Turn power off and re-connect the speaker cord. The "standby/timer" indicator blinks in amber. . Adjust the present time again. . No sound from the headphones. . Insert correctly. % . Adjust to an required volume. $ Sound is not produced from the left or right speakers. . Connect properly referring to "System connections". 6 The clock display blinks without changing the figures. . Adjust the present time again. . Timer operation is not possible. . Adjust the present time referring to "Clock adjustment". . . Set the timer ON time and OFF time. g . Press the TIMER key to set up the execution. dh Tuner section Knowledge sections Symptom Remedy Radio stations cannot be received. . Connect antennas. 7 . Select a band. . . Tune to the frequency of the desired station. . Noise interferes. . Install the outdoor antenna in an apart position from the road. . Switch the suspected electric appliance OFF. . Install the TV or the system at an increased distance between them. A station has been preset but it cannot be received by pressing the P.CALL key. . Preset stations with tunable frequencies. . . Preset stations again. . 81 In case of difficulty 81 In case of difficulty Symptoms related to MD standard Symptom Cause "DISC FULL" is displayed while the disc still has a remaining recordable time. . More than 255 tracks (track No. 256 or more) cannot be recorded. (There may be also cases in which recording is impossible while the track number is less than 256.) In such a case, the REMAIN time display shows "0:00". The possible recording time does not increase even when a short track is erased. . When the remaining time of the entire disc is less than 12 sec, the remaining time indication on the display becomes "0:00". When the total time of the deleted tracks exceeds 12 sec, the display changes to the recordable time.*1 . When a short track is deleted on a repeatedly edited disc, the remaining time may not increase. Tracks can not be connected. . Connection of the track resulting from edit processing may not be possible. . It is not permitted to combine two tracks which are recorded in different recording modes.*2 The total of the recorded time and remaining recording time does not match the total recording time of the MD (60, 74 or 80 minutes). . As the MD is recorded based on minimum recording units of 2 seconds, the consumed disc space may not coincide with the displayed time information.*3 When search is performed in a track which has been compiled by editing, the sound is sometimes interrupted. . This derives from the restriction in the MD system standard and not a malfunction. The track numbers are not assigned correctly. . Depending on the contents of the recorded source (CD etc.), the track numbers may not be assigned correctly. “READING”is displayed for an abnormally long time. . When a new recordable MD (with nothing recorded) is inserted, "READING" is displayed longer than usual. The time display becomes inaccurate with a monaurally recorded disc. . Monaural recording and stereo recording are executed according to different formats. This is not a malfunction. Input of 1792 title characters is not possible. . The title recording area is used in units of 7 characters, so that input of 1792 characters may not be possible. *1. W...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien