Login:
heruntergeladen wurde: 10   Dateigröße: 545 kb   Hersteller: Goodman Mfg  
Kategorie: Splitgeräte
@name

This unit contains totally enclosed, permanently lubricated outdoor fan motors and is designed for over/under or downfl ow applications. Standard Features • Dual high-efficiency scroll compressors with internal motor protection for 2-stage cooling • Totally enclosed, permanently lubricated outdoor fan motors • Enhanced copper tube/aluminum fi n coils • Fully charged R-22 systems • Belt-driven, variable-pitch sheave permits multispeed adjustment • Expansion valve evaporator coil • Time delay for

heruntergeladen wurde: 20   Dateigröße: 402 kb   Hersteller: Goodman Mfg  
Kategorie: Splitgeräte
@name

El GPC13H se aloja en un gabinete de acero galvanizado grueso, protegido por un acabado de pintura resistente a las radiaciones ultravioletas de alta calidad. Esta unidad permite aplicaciones en plantas bajas, en techos y está aprobada para viviendas modulares o prefabricadas. Características Estándar • Compresor con una válvula de escape interna que contribuye al ahorro de energía. • Motor PSC, motor EEM en unidades de 5 toneladas. • Descarga horizontal silenciosa • Tubo de cobre/ bobina d

heruntergeladen wurde: 8   Dateigröße: 368 kb   Hersteller: Goodman Mfg  
Kategorie: Splitgeräte
@name

Caracteristicas Estandar • Compresor con una valvula de escape interna que contribuye al ahorro de energia. • Motor EEM, motor PSC en unidades de 3 toneladas. • Flujo de aire convertible: horizontal o fl ujo descendente. • Tubo de cobre/Bobina de aleta de aluminio. • Motor de ventilador condensador completamente cerrado y constantemente lubricado. • Sistema R-22 completamente cargado. • Equipo de calefaccion electrica disponible como un accesorio de instalacion en campo Caracteristicas del Gabin

heruntergeladen wurde: 8   Dateigröße: 1 mb   Hersteller: Goodman Mfg  
Kategorie: Splitgeräte
@name

IO-357A 5151 San Felipe, Suite 500, Houston, TX 77056 3/10 © 2009 - 2010 Goodman Manufacturing Company, L.P. *NOTE: Please contact your distributor or our website for the applicable Specification Sheet or Technical Manual referred to in this manual. This Forced Air Central Unit Design Complies With Requirements Embodied in The American National Standard / National Standard of Canada Shown Below. ANSI Z21.47•CSA-2.3 Central Furnaces RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION. ATTENTION INSTALLI

heruntergeladen wurde: 17   Dateigröße: 326 kb   Hersteller: Goodman Mfg  
Kategorie: Splitgeräte
@name

ATTENTION INSTALLING PERSONNEL Prior to installation, thoroughly familiarize yourself with this Installation Manual. Observe all safety warnings. During installation or repair, caution is to be observed. It is your responsibility to install the product safely and to educate the customer on its safe use. Goodman Manufacturing Company, L.P. IO-355E 08/10 5151 San Felipe, Suite 500, Houston, TX 77056 © 2004-2010 Goodman Manufacturing Company, L.P. CONTENTS Important Safety Instructions.............

heruntergeladen wurde: 25   Dateigröße: 285 kb   Hersteller: Goodman Mfg  
Kategorie: Splitgeräte
@name

INDEX INTRODUCTION .................................................................... 2 REPLACEMENT PARTS ........................................................ 2 SAFETY INSTRUCTIONS ...................................................... 2 WARNINGS ............................................................................ 2 MODEL IDENTIFICATION ...................................................... 3 PRODUCT DESCRIPTION ..................................................... 3 UNIT INSPECTIO

heruntergeladen wurde: 14   Dateigröße: 285 kb   Hersteller: Goodman Mfg  
Kategorie: Splitgeräte
@name

To prevent the evaporator coil pan from “sweating” the DPI accessory insulation kit is to be used when performing this conversion. Note: The DPI kit is not supplied with this product and is to be purchased separately. See Table 8 for the correct DPI kit. ARUFor ARPT model AEPT model Insulation Kit 018-032 n/a DPI18-30/20 036-042 30 DPI36-42/20 048-061 036, 060 DPI48-61/20 Table 8 Refer to Figures 5 through 7 for the location of the components referenced in the following steps. Figure 5 illustrat

heruntergeladen wurde: 12   Dateigröße: 285 kb   Hersteller: Goodman Mfg  
Kategorie: Splitgeräte
@name

Do not install the air handler in a location either above or below the condenser that violates the instructions provided with the condenser. The clearance from a combustible surface to the unit is 0". However, service clearance is to take precedence. Allow a minimum of 24" in front of the unit for service clearance. When installing in an area directly over a finished ceiling (such as an attic), an emergency drain pan is required directly under the unit. See local and state codes for additional r

heruntergeladen wurde: 13   Dateigröße: 326 kb   Hersteller: Goodman Mfg  
Kategorie: Splitgeräte
@name

Do not connect to or use any device that is not design- certified by Goodman for use with this unit. Serious property damage, personal injury, reduced unitperformance and/or hazardous conditions may resultfrom the use of such non-approved devices. To prevent the risk of property damage, personalinjury, or death, do not store combustible materials oruse gasoline or other flammable liquids or vapors in the vicinity of this unit. CARBON MONOXIDE POISONING HAZARD - Special Warning for Installation o

heruntergeladen wurde: 5   Dateigröße: 224 kb   Hersteller: Goodman Mfg  
Kategorie: Splitgeräte
@name

contact International Division Goodman Manufactu ring Company, L.P. 7401 Security Way Houston, Texas 77040 713-861-2500-Telephone 713-863-2382-Facsimile 2 RP-616B Functional Parts Part No: Description: 11091204 11091203S 0131M00005P 11091207S 0131M00000P D6723306S B1368016S D6723311 0150M00000S B1368042 0150G00000P CAP100000370VAS CAP150000370VAS PCBFM131 B1141643 BLOWER MOTOR 1/2 HP, 3 SP, 8 PL (M6, M7) BLOWER MOTOR 1/3 HP, 3 SP, 6 PL (M4, M5) BLOWER MOTOR 1/3 HP,





Kategorien