Monitor 24°C (75°F) 26°C (79°F):18/24K 27°C (81°F):9/12K............ • The room temperature is adjustable as you desire by pressing the room temperature setting. • The adjustable range is up to 4°C (8°F) plus or minus. • Automatic operation will not show the set room temperature. • The room temperature automatically appears in the display indicator about 5 seconds after adjustment. Temperature Range16°°°°°C (61°°°°°F) Lower Limit 30°°°°°C (86°°°°°F) Upper Limit Each press changes unit of tempera

heruntergeladen wurde: 6   Dateigröße: 947 kb   Hersteller: Hyundai  
Kategorie: Splitgeräte
@name

2.36”) • Height limit: below 25ft. • Maximum tubing length: below 50ft. Tubing length over 25ft. 9/12 Btuh (Single or Multi-Zone) • Charge additional refrigerant amount, Parts of Indoor Unit No. Part Qty 1 Remote Control 1/unit 2 Remote Control Fixture 1/unit 3 Batteries 'LR03' (AAA) 2/unit 4 Manual 1 Parts of Outdoor Unit No. Part Qty 1 9/12 Btuh 4 Rubber Cushion 2 18/24 Btuh 4 Rubber Cushion 3 Drain Pipe 1 DETERMINATION OF INSTALLING POSITION Install the Air Conditioner(s) by taking into accou

heruntergeladen wurde: 5   Dateigröße: 947 kb   Hersteller: Hyundai  
Kategorie: Splitgeräte
@name

This will result in the release of refrigerant from the system into the atmosphere! 8) Re-install the caps on both service valves. This completes the charging of the system. Flare nut Flare valve Manifold gauges Charge cylinder Discharge Suction Vacuum pump INDOORUNITOUTDOORUNIT Diagram 1 (SINGLE ZONE SYSTEM SHOWN) Check the joints with a gas leak detector or soapy water for refrigerant leaks. If a leak is found, repair and recheck. After the indoor unit(s) have been installed, make sure that co

heruntergeladen wurde: 4   Dateigröße: 947 kb   Hersteller: Hyundai  
Kategorie: Splitgeräte
@name

• In cases where than two air conditioners are installed in the same room, individual operation may not be possible. ECR International Hyundai Ductless Split System4 OPERATION OPERATION ECR International Hyundai Ductless Split System5 1 Press the MODE button on the Remote Control. • Cold weather • High humidity • Hot weather • When air circulation is needed HEAT mode DRY mode COOL mode CIRCULATE mode 2 Press the ON/OFF button When the fan speed or air flow direction is to be changed. • When the

heruntergeladen wurde: 3   Dateigröße: 947 kb   Hersteller: Hyundai  
Kategorie: Splitgeräte
@name

control(s). BEFORE THE SEASON 1. CLEANING AIR FILTERS (ONCE EVERY TWO WEEKS) Clean the air filters at least once every two weeks to save elec-• Check that the air inlet and outlet of the indoor and outdoor tricity. Use the vacuum cleaner to remove dust from the air filter. units are not blocked. • Check that the ground wire is connected and there is no NOTE: In case the dust on the air filter cannot be easily wire breaks anywhere. removed with a vacuum cleaner, use a neutral clean-• Check that t

heruntergeladen wurde: 4   Dateigröße: 947 kb   Hersteller: Hyundai  
Kategorie: Splitgeräte
@name

BarFlare nut Fix pipe turning clamp handle. Pipe • See the “Determination of Installing Position”. Connecting of Tubing 1. Cutting and flaring of tubing: A. Cut the tubing on its straight part with the pipe cutter. B. Remove burrs from cut edges of pipes, which may cause a gas leak. C. Flaring of the pipe is done with the flaring tool. NOTE: Do not forget to install the flare nut before flaring 2. Pre-Connecting: Screw the tubing turning 3 to 5 times until hand tight. 3. Fastening: Fasten the co

heruntergeladen wurde: 6   Dateigröße: 947 kb   Hersteller: Hyundai  
Kategorie: Splitgeräte
@name

supply to the condenser. ! CAUTION ! Make sure wire connections are secure otherwise electrical malfunction may occur. TEST RUN TEST RUN • After the test, set the lever to ON (I) position. The unit will stop the operation and hereafter the remote control will • Check the installation again. control the unit. • First, set the lever to OFF(O) position, then to ON(I) and TEST position slowly. (During the test, the indicator light will blink) 9/12 Btuh 18/24 Btuh CABLE CONNECTION 9/12 Btuh (Single o

heruntergeladen wurde: 3   Dateigröße: 947 kb   Hersteller: Hyundai  
Kategorie: Splitgeräte
@name

• In heat mode water comes out the outdoor unit: The ambient air can condense on the pipes of the outdoor unit. ECR International Hyundai Ductless Split System9 BEFORE CALLING FOR SERVICE (Continued) PLEASE CHECK THE FOLLOWING THE UNIT(S) WON’T OPERATE COOL OPERATION IS NOT SATISFACTORY BEFORE CALLING FOR SERVICE (Continued) PLEASE CHECK THE FOLLOWING THE UNIT(S) WON’T OPERATE COOL OPERATION IS NOT SATISFACTORY Check the batteries in the Remote Control. .. Check that the power source is connecte

heruntergeladen wurde: 4   Dateigröße: 947 kb   Hersteller: Hyundai  
Kategorie: Splitgeräte
@name

• ..........Features of Heating Operation: ~ If there is frost on the outdoor unit, the heating capacity will drop. Therefore, defrosting operates automatically (approx. 5 to 12 minutes) and the indicator light on the indoor unit(s) will blink (red). ~ The room and outdoor fan does operate during defrosting and the unit will not run during this time. • To change the air flow Up or Down Press the Flap button. • Up/Down Moving range of Airflow Direction Control Plate. • Left-right airflow directio

heruntergeladen wurde: 6   Dateigröße: 947 kb   Hersteller: Hyundai  
Kategorie: Splitgeräte
@name

(Take care not to twist or crimp pipes during installation.) For Right Rear Sided, Right Sided and Lower Sided Piping NOTE: Do not apply excessive force to these parts. 1. For right side and lower side piping, cut the indoor unit base(s) with a hacksaw and deburr the cut end with a file. (See Fig. 5) 2. Hang the indoor unit(s) on the upper portion of the installation plate while inserting the vinyl-taped pipes through the wall hole. Engage the lower projection with the claws of the installation