* = B, L 2 Required to achieve ARI rating. A blower time delay is required to achieve ARI rating. 2AC13SplitSystemAirConditioner132AC13SplitSystemAirConditioner13 Cooling Performance with Air Handlers and Furnaces (30) Outdoor Model Indoor Model Variable Speed Furnace SEER EER Rated ARI Capacity1 Rated Sensible Capacity CFM Refrigerant Connection Refrigerant Line Size Indoor Metering Device Piston or Field Installed TXV Factory Installed TXV Outdoor Indoor SuctionLiquidReq'd Indoor2 Orifice Optional Field Installed OrificeSuctionLiquidSuctionLiquid 2AC13**30P RBCS2M30C****P RBCS2M30C****T --13.00 11.50 29,000 21,800 900 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 RBCS2M36V****P ---- 14.00 12.00 29,000 21,800 900 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,H,M,U)1P23NA E(C,M,U)2T23NA CMPEV050 13.50 11.50 28,200 21,200 1000 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,H,M,U)1P23NA E(C,M,U)2T23NA CMPEV075 13.50 11.50 28,200 21,200 1000 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,H,M,U)1P23NA E(C,H,M,U)2T23NA MPGAV050 14.00 11.50 28,200 21,200 1000 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,H,M,U)1P23NA E(C,H,M,U)2T23NA MPGAV075 14.00 11.50 28,200 21,200 1000 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,H,M,U)1P23NB E(C,H,M,U)2T23NB CMPEV0100 13.50 11.50 28,200 21,200 1000 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,H,M,U)1P23NB E(C,H,M,U)2T23NB MPGAV100 14.00 11.50 28,200 21,200 1000 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,H,M,U)1P29NA E(C,H,M,U)2T29NA CMPEV050 13.50 12.00 29,000 21,800 1000 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,H,M,U)1P29NA E(C,H,M,U)2T29NA CMPEV075 13.50 12.00 29,000 21,800 1000 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,H,M,U)1P29NA E(C,H,M,U)2T29NA MPGAV050 14.00 12.00 29,000 21,800 1000 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,H,M,U)1P29NA E(C,H,M,U)2T29NA MPGAV075 14.00 12.00 29,000 21,800 1000 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,M,U)1P30NA E(C,M,U)2T30NA CMPEV050 13.50 11.50 28,600 21,500 1000 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,M,U)1P30NA E(C,M,U)2T30NA CMPEV075 13.50 11.50 28,600 21,500 1000 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,M,U)1P30NA E(C,M,U)2T30NA MPGAV050 14.00 12.00 28,600 21,500 1000 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,M,U)1P30NA E(C,M,U)2T30NA MPGAV075 14.00 12.00 28,600 21,500 1000 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,M,U)1P30NB E(C,M,U)2T30NB CMPEV050 14.00 11.50 28,600 21,500 1000 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,M,U)1P30NB E(C,M,U)2T30NB MPGAV075 14.00 11.50 28,600 21,500 1000 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,M,U)1P36NA E(C,M,U)2T36NA CMPEV050 13.50 12.00 29,400 22,100 1000 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,M,U)1P36NA E(C,M,U)2T36NA CMPEV075 13.50 12.00 29,400 22,100 1000 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,M,U)1P36NA E(C,M,U)2T36NA MPGAV050 14.00 12.00 29,400 22,100 1000 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,M,U)1P36NA E(C,M,U)2T36NA MPGAV075 14.00 12.00 29,400 22,100 1000 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,H,M,U)1P36NB E(C,H,M,U)2T36NB CMPEV0100 14.00 12.00 29,400 22,100 1000 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,H,M,U)1P36NB E(C,H,M,U)2T36NB MPGAV0100 14.00 12.00 29,400 22,100 1000 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on ARI Standard 210/240. ** = B, L, BC, LC 2 Required to achieve ARI rating. * = B, L A blower time delay is required to achieve ARI rating. 2AC13SplitSystemAirConditioner132AC13SplitSystemAirConditioner13 Cooling Performance with Air Handlers and Furnaces (36, 42, 48, 60) Outdoor Model Indoor Model Variable Speed Furnace SEER EER Rated ARI Capacity1 Rated Sensible Capacity CFM Refrigerant Connection Refrigerant Line Size Indoor Metering Device Piston or Field Installed TXV Factory Installed TXV Outdoor Indoor SuctionLiquidReq'd Indoor2 Orifice Optional Field Installed OrificeSuctionLiquidSuctionLiquid 2AC13**36P RBCS2M36C****P RBCS2M36C****T --13.00 11.50 35,000 27,000 1060 3/4 3/8 3/4 3/8 3/4 3/8 .076 A2TXV01 RBCS2M36V****P ---- 14.00 12.00 35,600 27,400 1060 3/4 3/8 3/4 3/8 3/4 3/8 .076 A2TXV01 E(C,M,U)1P36NA E(C,M,U)2T36NA MPGAV050 13.50 11.50 35,000 27,000 1060 3/4 3/8 3/4 3/8 3/4 3/8 .076 A2TXV01 E(C,M,U)1P36NA E(C,M,U)2T36NA MPGAV075 13.50 11.50 35,000 27,000 1060 3/4 3/8 3/4 3/8 3/4 3/8 .076 A2TXV01 E(C,H,M,U)1P36NB E(C,H,M,U)2T36NB CMPEV100 13.50 11.50 34,800 26,800 1060 3/4 3/8 3/4 3/8 3/4 3/8 .076 A2TXV01 E(C,H,M,U)1P36NB E(C,H,M,U)2T36NB MPGAV100 13.50 12.00 35,200 27,100 1060 3/4 3/8 3/4 3/8 3/4 3/8 .076 A2TXV01 E(C,H,M,U)1P43NB E(C,H,M,U)2T36NB CMPEV0100 13.50 12.00 35,800 27,600 1060 3/4 3/8 7/8 3/8 3/4 3/8 .076 A2TXV01 E(C,H,M,U)1P43NB E(C,H,M,U)2T36NB MPGAV100 13.50 12.00 35,800 27,600 1060 3/4 3/8 7/8 3/8 3/4 3/8 .076 A2TXV01 2AC13*42P RBCS2M42C****P RBCS2M42C****T --13.00 11.00 39,500 27,600 1250 7/8 3/8 7/8 3/8 7/8 3/8 .080 A2TXV02 RBCS2M42V****P ---- 13.50 12.00 39,500 27,600 1250 7/8 3/8 7/8 3/8 7/8 3/8 .080 A2TXV02 E(C,H,M,U)1P43NB E(C,H,M,U)2T43NC MPGAV050 13.50 12.00 40,000 28,000 1400 7/8 3/8 7/8 3/...
Dieses Handbuch ist für folgende Modelle:Splitgeräte - 2AC13 (946.18 kb)
Splitgeräte - 2AC13 (946.18 kb)
Splitgeräte - 2AC13 (946.18 kb)