Login:
Stimmen - 2, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Ducane (HVAC), modell 2AC13

Hersteller: Ducane (HVAC)
Dateigröße: 946.18 kb
Dateiname: d2ac13blbclc-100.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


See limited warranty for details. 2AC13 Split System Air Conditioner 13 2 AC 13 B 24 P - 1 A Model Number Guide Refrigerant – 2 = R22 AC = Condenser 13 - 13 SEER Nominal BC = Wire Guard + 76dBA LC = Louvered + 76dBA B = Wire Guard L = Louvered Minor Revision Code Major Revision Code Voltage P - 208-230v/60hz Single Phase Nominal Capacity 24 - 24,000 Btuh Model Voltage/ Hz/ Phase Voltage Range Min. Circuit Amp. Maximum Over Current Device (amps) Compressor Fan Motor Refrig. Charge (oz.): Weight (lbs.) Rated Load (Amps) Locked Rotor (Amps) Full Load Amps Rated HP Nom. RPM Wire Guard/ Louvered 2AC13**18P 208-230/60/1 197 - 253 8.5 15 6.9 35 0.7 1/10 1075 84 128/138 2AC13**24P 208-230/60/1 197 - 253 12.2 20 11.3 51 0.7 1/10 1075 89 130/140 2AC13**30P 208-230/60/1 197 - 253 14.2 20 12.0 60 0.7 1/10 1075 97 166/179 2AC13**36P 208-230/60/1 197 - 253 15.0 25 16.2 82 0.7 1/10 1075 128 172/187 2AC13*42P 208-230/60/1 197 - 253 18.4 30 13.1 78 1.1 1/5 1075 122 186/210 2AC13*48P 208-230/60/1 197 - 253 22.4 35 15.4 86 1.1 1/5 1075 132 212/229 2AC13*60P 208-230/60/1 197 - 253 25.5 40 18.5 102 1.1 1/5 1075 188 226/245 Electrical and Physical Data ** = B, L, BC, LC : Factory charged for 15 feet of line set. Adjust per Installation Instructions * = B, L Dimensions (in.) and Sound Ratings Model Dimensions B, L Sound Rating (dBa) BC, LC Sound Rating (dBa) A - width (in.) B - depth (in.) C - height (in.) 2AC13**18P 22 1/2 22 1/2 25 77 75 2AC13**24P 22 1/2 22 1/2 29 77 75 2AC13**30P 30 30 29 80 76 2AC13**36P 30 30 33 80 76 2AC13*42P 30 30 37.5 78 --- 2AC13*48P 30 30 29.5 80 --- 2AC13*60P 30 30 33.5 80 --- ** = B, L, BC, LC * = B, L 2AC13 Split System Air Conditioner132AC13SplitSystemAirConditioner13 Cooling Performance with Evaporator Coils Outdoor Model Indoor Model SEER EER Rated ARI Capacity1 Rated Sensible Capacity CFM Refrigerant Connection Refrigerant Line Size Indoor Metering Device Piston or Field Installed TXV Factory Installed TXV Outdoor Indoor SuctionLiquidReq'd Indoor2 Orifice Optional Field Installed OrificeSuctionLiquidSuctionLiquid 2AC13**18P E(C,M,U)1P18N(A,B) E(C,M,U)2T18N(A,B) 13.00 11.00 17,000 12,200 550 3/4 3/8 3/4 3/8 3/4 3/8 .053 A2TXV01 E(C,M,U)1P19NA E(C,M,U)2T19NA 13.00 11.50 17,000 12,200 550 3/4 3/8 3/4 3/8 3/4 3/8 .053 A2TXV01 E(C,H,M,U)1P23N(A,B) E(C,H,M,U)2T23N(A,B) 13.00 11.50 17,000 12,200 550 3/4 3/8 3/4 3/8 3/4 3/8 .053 A2TXV01 E(C,M,U)1P24N(A,B) E(C,M,U)2T24N(A,B) 13.00 11.50 17,000 12,200 550 3/4 3/8 3/4 3/8 3/4 3/8 .053 A2TXV01 2AC13**24P E(C,M,U)1P19NA E(C,M,U)2T19NA 13.00 11.00 22,800 17,100 750 3/4 3/8 3/4 3/8 3/4 3/8 .062 A2TXV01 E(C,H,M,U)1P23N(A,B) E(C,H,M,U)2T23N(A,B) 13.00 11.00 23,200 17,400 750 3/4 3/8 3/4 3/8 3/4 3/8 .062 A2TXV01 E(C,M,U)1P24N(A,B) E(C,M,U)2T24N(A,B) 13.00 11.00 23,000 17,300 750 3/4 3/8 3/4 3/8 3/4 3/8 .062 A2TXV01 E(C,H,M,U)1P29NA E(C,H,M,U)2T29NA 13.00 11.50 23,000 17,300 750 3/4 3/8 3/4 3/8 3/4 3/8 .062 A2TXV01 2AC13**30P E(C,H,M,U)1P23N(A,B) E(C,H,M,U)2T23N(A,B) 13.00 11.00 27,800 20,900 900 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,H,M,U)1P29NA E(C,H,M,U)2T29NA 13.00 11.00 28,600 21,500 900 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,M,U)1P30N(A,B,C) E(C,M,U)2T30N(A,B,C) 13.00 11.00 28,200 21,200 900 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 E(C,H,M,U)1P36N(A,B,C) E(C,H,M,U)2T36N(A,B,C) 13.00 11.00 29,000 21,800 900 3/4 3/8 3/4 3/8 3/4 3/8 .070 A2TXV01 2AC13**36P E(C,H,M,U)1P29NA E(C,H,M,U)2T29NA 13.00 10.50 34,600 26,600 1060 3/4 3/8 3/4 3/8 3/4 3/8 .076 A2TXV01 E(C,H,M,U)1P36N(A,B,C) E(C,H,M,U)2T36N(A,B,C) 13.00 11.00 34,600 26,600 1060 3/4 3/8 3/4 3/8 3/4 3/8 .076 A2TXV01 E(C,H,M,U)1P43NB E(C,H,M,U)2T43NBC 13.00 11.00 35,200 27,100 1060 3/4 3/8 7/8 3/8 7/8 3/8 .076 A2TXV01 2AC13*42P E(C,H,M,U)1P43NB E(C,H,M,U)2T43NB 13.00 11.50 40,000 28,000 1250 7/8 3/8 7/8 3/8 7/8 3/8 .080 A2TXV02 E(C,M,U)1P48N(B,C) E(C,M,U)2T48N(B,C) 13.00 11.00 39,000 27,200 1250 7/8 3/8 7/8 3/8 7/8 3/8 .080 A2TXV02 E(C,H,U)1P49NC E(C,H,U)2T49NC 13.00 11.00 40,000 28.000 1250 7/8 3/8 7/8 3/8 7/8 3/8 .080 A2TXV02 2AC13*48P E(C,H,M,U)1P43NB E(C,H,M,U)2T43NB 13.00 11.50 45,000 32,000 1600 7/8 3/8 7/8 3/8 7/8 3/8 .088 A2TXV02 E(C,M,U)1P48N(B,C) E(C,M,U)2T48N(B,C) 13.00 12.00 45,000 32,000 1600 7/8 3/8 7/8 3/8 7/8 3/8 .088 A2TXV02 E(C,H,U)1P49NC E(C,H,U)2T49NC 13.00 11.50 46,000 32,600 1600 7/8 3/8 7/8 3/8 7/8 3/8 .088 A2TXV02 E(C,M,U)1P50NC E(C,M,U)2T50NC 13.00 11.50 45,000 32,000 1600 7/8 3/8 7/8 3/8 7/8 3/8 .088 A2TXV02 E(C,U)1P60ND E(C,U)2T60ND 13.00 11.50 45,000 32,000 1600 7/8 3/8 7/8 3/8 7/8 3/8 .088 A2TXV02 E(C,H,U)1P62NC E(C,H,U)2T62NC 13.00 12.00 45,500 32,300 1600 7/8 3/8 7/8 3/8 7/8 3/8 .088 A2TXV02 E(C,H,U)1P62ND E(C,H,U)2T62ND 13.00 12.00 45,500 32,300 1600 7/8 3/8 7/8 3/8 7/8 3/8 .088 A2TXV02 2AC13*60P E(C,H,U)1P49NC E(C,H,U)2T49NC 13.00 11.00 53,000 38,600 1800 7/8 3/8 7/8 3/8 1-1/8 3/8 .098 A2TXV02 EH1P49ND --13.00 11.00 53,000 38,600 1800 7/8 3/8 7/8 3/8 1-1/8 3/8 .098 A2TXV02 E(C,H,U)1P62NC E(C,H,U)2T62NC 13.00 11.50 54,000 39,400 1800 7/8 3/8 7/8 3/8 1-1/8 3/8 .098 A2TXV02 E(C,...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - 2AC13 (946.18 kb)
Splitgeräte - 2AC13 (946.18 kb)
Splitgeräte - 2AC13 (946.18 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien