Login:
Stimmen - 2, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Friedrich, modell 2AC13

Hersteller: Friedrich
Dateigröße: 946.18 kb
Dateiname: d2ac13blbclc-100.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


2 Required to achieve ARI rating. * = B, L A blower time delay is required to achieve ARI rating. 2AC13 Split System Air Conditioner 13 Form No. D2AC13B,L,BC,LC-100 ( ©200 llied Air Enterprises Inc., a Lennox International Inc. Company 1-800-448-5872 All specifications and illustrations subject to change without notice and without incurring obligations. A blower time delay is required to achieve ARI rating. Which is part of these air handler and furnace controls. Accessories Description Where Used Catalog # Hard Start Kit 2ac13**18, 24, 30, 36 12W16 Hard Start Kit 2ac13**42, 48 12W18 Hard Start Kit 2ac13**60 43W33 Low Pressure Switch All Models 14W08 High Pressure Switch 2ac13**18, 24, 30, 36 14W09 High Pressure Switch 2AC13**42, 48, 60 Factory installed Low Ambient All models 14W11 Short cycle protection All models 14W07 Liquid line solenoid All models 20443001 Crankcase Heater 2AC 13**18, 24, 30, 36, 42, 48 14W06 Crankcase Heater 2ac13**60 Factory installed Compressor Sound Blanket 2ac13**18, 24, 30, 36 14W03 Compressor Sound Blanket 2AC13**42, 48, 60 47W04 TXV Kit 2ac13**18, 24, 30, 36 A2TXV01 TXV Kit 2ac13**42, 48, 60 A2TXV02 Outdoor Model Indoor Model Indoor Temp DB/WB .F Outdoor Temp - DB.F 65 82 95 105 115 Btuh S/T kW Btuh S/T kW Btuh S/T kW Btuh S/T kW Btuh S/T kW 2AC13**18P E*1P19 75/63 16,900 .71 1.25 16,100 .76 1.42 15,700 .78 1.49 15,000 .81 1.55 13,800 .82 1.60 80/67 18,200 .67 1.29 17,400 .71 1.47 17,000 .73 1.55 16,100 .76 1.61 14,900 .76 1.67 85/71 19,400 .65 1.34 18,500 .69 1.53 18,000 .71 1.61 17,100 .74 1.68 15,800 .74 1.74 2AC13**24P E*1P23 75/63 23,000 .70 1.81 22,000 .75 1.98 21,000 .77 2.05 20,000 .80 2.11 19,000 .81 2.16 80/67 25,000 .66 1.85 24,000 .70 2.03 23,000 .72 2.11 22,000 .75 2.17 20,000 .75 2.23 85/71 26,000 .64 1.90 25,000 .68 2.09 25,000 .70 2.17 23,000 .73 2.24 21,000 .73 2.30 2AC13**30P E*1P29 75/63 28,000 .69 2.30 27,000 .73 2.47 26,000 .76 2.54 25,000 .79 2.60 23,000 .79 2.65 80/67 30,000 .65 2.34 29,000 .69 2.52 29,000 .71 2.60 27,000 .74 2.66 25,000 .74 2.72 85/71 32,000 .63 2.39 31,000 .67 2.58 30,000 .69 2.66 29,000 .72 2.73 27,000 .72 2.79 2AC13**36P E*1P36 75/63 34,000 .70 2.85 33,000 .75 3.02 32,000 .77 3.09 30,000 .80 3.15 28,000 .81 3.20 80/67 37,000 .66 2.89 35,000 .70 3.07 34,000 .72 3.15 33,000 .75 3.21 30,000 .75 3.27 85/71 39,000 .64 2.94 37,000 .68 3.13 37,000 .70 3.21 35,000 .73 3.28 32,000 .73 3.34 2AC13*42P E*1P43 75/63 40,000 .68 3.18 38,000 .72 3.35 37,000 .75 3.42 35,000 .78 3.48 33,000 .78 3.53 80/67 43,000 .64 3.22 41,000 .68 3.40 40,000 .70 3.48 38,000 .73 3.54 35,000 .73 3.60 85/71 45,000 .62 3.27 43,000 .66 3.46 42,000 .68 3.54 40,000 .70 3.61 37,000 .71 3.67 2AC13*48P E*1P48 75/63 45,000 .69 3.61 43,000 .73 3.78 42,000 .76 3.85 40,000 .79 3.91 37,000 .79 3.96 80/67 48,000 .65 3.65 46,000 .69 3.83 45,000 .71 3.91 42,000 .74 3.97 40,000 .74 4.03 85/71 51,000 .63 3.70 49,000 .67 3.89 47,000 .69 3.97 45,000 .72 4.04 42,000 .72 4.10 2AC13*60P E*1P62 75/63 53,000 .72 4.40 51,000 .77 4.57 50,000 .79 4.64 48,000 .82 4.70 44,000 .83 4.75 80/67 58,000 .67 4.44 56,000 .72 4.62 54,000 .74 4.70 51,000 .77 4.76 47,000 .77 4.82 85/71 61,000 .65 4.49 59,000 .70 4.68 57,000 .72 4.76 54,000 .75 4.83 50,000 .75 4.89 Cooling Performance with Extended Ratings ** = B, L, BC, LC * = B, L Printed in the U.S.A. D&S 9) 02/0 9 A ...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - 2AC13 (946.18 kb)
Splitgeräte - 2AC13 (946.18 kb)
Splitgeräte - 2AC13 (946.18 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien