Login:
Stimmen - 1, Durchschnittliche Bewertung: 3 ( )

Anleitung Bryant, modell DSB-F183L

Hersteller: Bryant
Dateigröße: 229.03 kb
Dateiname: 8a46e19a-bf28-4efa-85f8-068a8c3db7e0.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


AIR OUT AIR IN Fan Direction (Up/Down) Fan Direction (Left/Right) MODE SLEEP ON/OFF TIMER ENTER/ CANCEL FANSPEED TURBO/MILD FANDIR. LOCATION OF CONTROLS OPERATING SECTION INDOOR UNIT OUTDOOR UNIT Connection Cover Remove cover to access the AC connection from this unit to the indoor unit. Service Valves The indoor and outdoor units are connected by copper tubes which are connected here. AIR IN AIR OUT INDOOR UNIT DISPLAY 3 Remote Control Signal Receiver This place is the part to receive the signal if it receives the signal, you can hear the signal “beep. beep”. There is a switch panel at inside of Front Panel. At the time of operating, open the Front Panel. Emergency switch can be used when the remote controller is lost or Testing. Remote switch is usually used by remote controller. Indoor Unit Display Switch Panel ON (Red) Lights when the operation is going on. Air clean (Green) Timer (Yellow) Lights during the time reservation mode. Quick (Red) Lights during the time Quick Mode. REMOCON EMERGENCY REMOTE CONTROLLER FAN SPEED Button Press to select the fan speed (High " ", Middle " ", Low " "). AUTO DSB-F183L MODE Button Press to cycle through the modes (Auto/Quick/Cool/Fan/Dehumidifier) SLEEP Button Press to set the unit for the sleep mode. TIMER ON/OFF Button Press to set the unit off or on time. (0.5, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 8, 10, 12, 16, 20, 24hr) TIMER ENTER/CANCEL Button Press to enter a timer setting or to cancel timer setting REMOTE DISPLAY MODE SLEEP ON/OFF TIMER ENTER/ CANCEL FAN SPEED TURBO/MILD FAN DIR. Display Displays information pertaining to unit. ON/OFF Button (Blue) Press to turn the unit on or off. TEMPERATURE Buttons Press to raise or lower the desired temperature. FAN DIR. Button Press to select up/down direction for fan. TURBO/MILD Press to select super power operation (Turbo) mode COVER Slide down to access most of the remote buttons. Slide down further to access the battery compartment. MODE Indicators (Auto/Quick/Cool/Fan/Dehumidifier) Lights to indicate the mode selected. TIMER Indicators (Include sleep) Lights to indicate the timer function mode. FAN DIRECTION Indicators Lights to indicate the fan direction. NATURAL Indicator Lights to indicate the speeds simulating a breeze. FAN Indicators Lights to indicate the fan speed. AUTO TEMPERATURE & RESERVATION TIME lndicat Lights to indicate the temperature or time. 4 OPERATION CONNECTING THE AC CORD The outdoor unit is connected to the indoor unit through the AC connecting wire or connection cord. To connect the indoor unit to AC, follow the procedures below: 1. Insert the attached AC plug into a 2-pronged Only 220V or 220V~240V AC outlet. AC Outlet and Plug Plug into Only 220V or 220V~240V AC Outlet. NOTES: • Never connect the AC line cord plug to other than the specified voltage (Only 220V or 220V~240V). • Use the attached power cord only. • If the outlet is a 3-pronged type or other, have an electrician install a new outlet. • The new air conditioner system should be on it’s own 220V circuit. Contact your local electrical installer for installation. INFORMATION: 1. The plug shall be connected to a ground socket outlet, and the interconnection cord shall be connected by an authorized electrician or specialist. 2. Information for interconnection cable: 3. Contact service man for the installation shall be in accordance with national wiring regulation Items Specifications Under 12K class AC 250V, 16A, H05VV-Fx1.0m2 Above 12K class AC 250V, 16A, H05VV-Fx1.5m2 HOW TO INSTALL BATTERIES To install the batteries, follow the procedures below: BATTERY PRECAUTIONS The precautions below should be followed when using batteries in this device: 1. Use only the size and type of batteries specified. 2. Be sure to follow the correct polarity when installing the batteries as indicated in the battery compartment. Reversed batteries may cause damage to the device. 3. Do not mix different types of batteries together (e.g. Alkaline and Carbon-zinc) or old batteries with fresh ones. 4. If the device is not to be used for a long period of time, remove the batteries to prevent damage or injury from possible battery leakage. 5. Do not try to recharge batteries not intended to be recharged; they can overheat and rupture. (Follow battery manufacturer’s directions). 1. Slide down the cover to access most of the remote buttons. Slide down further to access the battery compartment. 2. Insert two “AAA” size Alkaline batteries following the polarity diagram below. ON/OFF TIMER ENTER/ CANCEL TURBO/MILD +– +– 5 SETTING THE UNIT FOR REMOTE OPERATION After the unit is fully connected and plugged in, it can be turned on. To turn the unit on and set it for remote operation, follow the procedures below: 1. Open the indoor unit’s cover and make sure the EMERGENCY/ REMOTE switch is set to the REMOTE position; this will allow the unit to operate with the remote controller. 2. Press the ON/OFF button on the remote controller to turn on the unit. The On LED will light on the...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - DSB-F183L (229.03 kb)
Splitgeräte - DSB-F183L (229.03 kb)
Splitgeräte - DSB-F183L (229.03 kb)
Splitgeräte - DSB-F183L (229.03 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien