Login:
Stimmen - 4, Durchschnittliche Bewertung: 2.8 ( )

Anleitung Kenwood, modell TH-K2AT

Hersteller: Kenwood
Dateigröße: 1.09 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:

Anleitung Zusammenfassung


Press and release KEY. Press [KEY1], [KEY2]. Press KEY1 momentarily, release KEY1, then press KEY2. Press [KEY] (1 s). Press and hold KEY down for a second. Press [KEY1]+[KEY2]. Press and hold KEY1 down, then press KEY2 If there are more. than two keys, press and hold down each key in turn until the final key has been pressed. Press ][KEY]+[ . With the transceiver OFF, press and hold KEY, then switch ON the transceiver power by pressing ][ (POWER). Since the amateur radio bands are slightly different from country to country, the following meter band descriptions are used in this manual. • 2 m band: 144 ~ 148 MHz or 144 ~ 146 MHz • 70 cm band: 430 ~ 440 MHz x PREPARATION PREPARATION Note: Because the battery pack is provided uncharged, you must charge the battery pack before using it with the transceiver. To charge the battery pack, refer to “CHARGING THE PB-43N Ni-MH BATTERY PACK (Other than TH-K2AT K2/ M2, TH-K4AT M2)” {page 6}. 1 Unlock (open) the safety catch located at the bottom of the battery pack. 2 Match the guides of the battery pack with the corresponding grooves on the upper rear of the transceiver, then firmly press the battery pack to lock it in place. 3 Flip the safety catch into place to prevent accidentally pressing the release latch and removing the battery pack. 1 4 4 INSTALLING ALKALINE BATTERIES 1 To open the BT-14 battery case lid, insert your thumb or finger into the hole on the top of the battery case, then pull the cover up. 2 2 2 • Be sure to match the battery polarities with those marked in the bottom of the battery case. 3 Align the two tabs at the bottom of battery case, then close the cover until the locking tabs on top click. 4 To install the battery case onto (or remove it from) the transceiver, follow steps 1 to 3 of “INSTALLING THE PB-43N Ni-MH BATTERY PACK” {page 1}. Note: . Do not use Manganese batteries or Ni-Cd batteries in place of Alkaline batteries. . Always replace all batteries at the same time. Mixing old and new batteries or mixing types (such as Alkaline with zinc carbon) will reduce overall performance and could cause leakage or rupture. . Remove all batteries from the case when it is not expected to be in use for several months. . The voltage of new Alkaline batteries varies slightly, depending on the manufacturer. Thus, the high battery power indicator may not appear even though new Alkaline batteries are installed {page 83}. . To lift the battery pack safety catch, use a piece of hardened plastic or metal, such as a screwdriver, that is no more than 6 mm wide and 1 mm thick. It is imperative that you place the implement under only the lip of the safety catch so that you do not damage the release latch. 3 INSTALLING THE ANTENNA INSTALLING THE ANTENNA ATTACHING THE HAND STRAP (OTHER THAN TH-K2AT K/ K2) If desired, you can attach the supplied hand strap to the transceiver. Strap 4 INSTALLING THE BELT CLIP INSTALLING THE BELT CLIP 1 Loosely insert the two supplied screws into the holes on the back panel of the transceiver. 2 Slide the belt hook into position, under the screws. 3 Tighten the screws until secure. Note: When the belt hook is not attached to the transceiver, remove the screws from the transceiver to avoid scratching other materials. 5 CHARGING THE PB-43N Ni-MH BATTERY PACK (OTHER THAN TH-K2AT K2/ M2, TH-K4AT M2) CHARGING THE PB-43N Ni-MH BATTERY PACK (OTHER THAN TH-K2AT K2/ M2, TH-K4AT M2) 1 Confirm that the transceiver power is OFF. • While charging the battery pack, leave the transceiver power OFF. 2 Insert the charger plug into the DC IN jack of the transceiver. DC IN jack 3 Plug the charger into an AC wall outlet. • Charging starts. 4 It takes approximately 12 hours to charge an empty PB-43N Ni-MH battery pack. After 12 hours, remove the charger plug from the transceiver DC IN jack. 5 Unplug the charger from the AC wall outlet. 6 Note: . Never leave the battery pack in direct sunlight. . The transceiver becomes warm while charging the battery pack. . While the battery pack is charged, the ambient temperature must be within 0° C ~ 40° C (32° F ~ 104° F). Otherwise, charging does not start. If the transceiver senses that the temperature is more than 60° C (140° F) during charging, the transceiver stops charging. . Before recharging the battery pack, use the battery pack until the transceiver stops receiving. . Do not plug the charger into the DC IN jack for more than 24 hours. . Unplug the charger as soon as possible after the charging period is over. . After the battery pack is charged, do not unplug and plug the charger into the AC outlet again. Unpluging the charger will reset the charging timer and the battery pack will be charged again. This could result in over-charging. . If the battery pack is recharged repeatedly before the battery pack is not fully used, the memory effect (the battery pack will not allow the charger to recharge the battery to more than a certain voltage level) may occur. In this case, turn the transceiver ON until it stop...

Dieses Handbuch ist für folgende Modelle:
HandFunkgeräte - TH-K2E (1.09 mb)
HandFunkgeräte - TH-K2ET (1.09 mb)
HandFunkgeräte - TH-K4AT (1.09 mb)
HandFunkgeräte - TH-K4E (1.09 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien