Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung EdgeStar, modell AP410W

Hersteller: EdgeStar
Dateigröße: 2.58 mb
Dateiname: 6ac9f927-39ca-47cb-908e-0c6af22f80a0.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


We would like you to be able to fully utilize all features of this portable air conditioner, so please take the time to read this owner’s manual in full prior to using the unit. Energy saving tips: 1. Use the portable air conditioner for the recommended room size. Rooms that are too small can cause the unit to short cycle and work inefficiently. Rooms that are too large will never cool completely. 2. Be careful not to obstruct the air flow coming out of the portable air conditioner. A powerful, unobstructed airflow is crucial for optimum cooling. 3. Keep blinds and curtains closed during the sunniest part of the day. 4. Clean the pre-filter often, and replace the activated carbon filter as needed (it should be replaced twice a year under normal conditions). 5. Close your fireplace damper, floor grills, and wall grills to prevent cool air from escaping. 6. Avoid opening doors frequently 7. Note that each additional person in room adds between 100-150 BTU of heat, so the more people in a room, the more cooling capacity is required 8. Set the portable air conditioner to maximum cooling and high speed airflow when you first start it up, and then adjust the unit to a comfortable setting. Notes: The portable air conditioner must be plugged into an appropriate power outlet. Refer to the rating label on the back of the unit for more information. The portable air conditioner is a compressor-driven cooling system. The air conditioner has an anti-overheating safety feature that can delay the compressor from starting for three minutes after the air conditioner turns on or when a mode change is made. If the compressor does not immediately start, it is likely because of this feature. To protect the compressor from overheating or freezing, it will only operate when the ambient temperature is between 61° and 97°F. Always unwind the power cord completely before use. Please note that in Cooling, Auto, and Dry modes, the exhaust hose must be used. When switching into the Cooling mode, cooling may be temporarily delayed as the unit cools down. Specifications Model AP410W Maximum Room Size (cooling)* 400 ft. Power consumption for cooling mode 1000W Air flow 212 ft./m Humidity removal capacity 2.11 p/h Noise level <54 dbA Power supply 115V/ 60Hz Compressor Rotary Refrigerant R-22 Refrigerant Load 15.2 oz Timer 1-12 hours Thermostat 61°-88°F Net weight 70.5 pounds Dimensions 29 1/4"h x 15"w x 14 3/4"d Box dimensions 29 15/16"h x 21"w x 17 3/8"d *Please note that maximum room sizes are under ideal conditions. Actual cooling performance may vary Safety precautions: 1. Transport the portable air conditioner in an upright position only. If the unit is tipped over, make sure it stands upright for at least 3 hours prior to turning it on. 2. Always place the unit on a level surface. 3. In order to cool, the hot air from the exhaust port in the rear of the portable air conditioner must be exhausted outside the room. 4. Make sure the portable air conditioner is connected to a grounded power outlet. 5. This portable air conditioner is designed to operate in an ambient temperature of 61°-97° F. 6. This portable air conditioner has been designed for residential use. 7. Always turn the portable air conditioner off before unplugging it. 8. Do not damage the power cord. 9. Do not use this portable air conditioner for functions other than those described in this owner’s manual. 10. Do not tilt the portable air conditioner. 11. Do not cover or obstruct the intake or outlet grills. 12. Do not use the portable air conditioner in a wet room- such as a bathroom or laundry room- to avoid the possibility of shock. 13. Do not bend or crush the exhaust hose while in use. 14. Do not sit on, or place articles on, the portable air conditioner. 15. Do not touch the portable air conditioner with wet or damp hands 16. Do not let chemical substances come into contact with the portable air conditioner. 17. Do not use the portable air conditioner in the presence of flammable substances or vapors such as alcohol, insecticides, gas, etc. 18. Do not use the plug to start or stop the unit. 19. Do not yank on the electric cord or place it near a source of heat. If the electric cord is damaged, it must be replaced by an authorized service agent. 20. Always use the control panel to start or stop the portable air conditioner. 21. Always allow for air flow around the portable air conditioner of at least 20”. 22. Always turn off the portable air conditioner when not in use. 23. Always turn the portable air conditioner off and unplug it after use, before cleaning, before carrying out maintenance, and before moving it. 24. It the electrical socket is different from the plug, have a professionally qualified electrician replace the socket with a suitable one. Do not use adapter plugs, multiple sockets, or extension cords. 25. The filter must be used at all times. When removing the filter for cleaning, turn off the unit and unplug it. 26. Make sure all children are properly sup...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien