Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.3 ( )

Anleitung Kenmore, modell CS-E9GFEW-2

Hersteller: Kenmore
Dateigröße: 3.81 mb
Dateiname: s_e9_12_18gfe2.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


CS-E9GFEW / CU-E9GFE, CS-E12GFEW / CUE12GFE, CS-E18GFEW / CU-E18GFE, Order No.RAC0704001C2. TABLE OF CONTENTS PAGE 1 Safety Precautions-----------------------------------------------2 2 Specifications -----------------------------------------------------4 2.1. CS-E9GFEW-2 CU-E9GFE-2 -------------------------4 2.2. CS-E12GFEW-2 CU-E12GFE-2 ----------------------6 2.3. CS-E18GFEW-2 CU-E18GFE-2 ----------------------8 3 Location of Controls and Components ------------------10 3.1. Indoor Unit--------------------------------------------------10 3.2. Outdoor Unit -----------------------------------------------10 3.3. Remote Control -------------------------------------------10 4 Dimensions--------------------------------------------------------11 4.1. Outdoor Unit -----------------------------------------------11 5 Refrigeration Cycle Diagram --------------------------------13 5.1. CS-E9GFEW-2 CU-E9GFE-2CS-E12GFEW2 CU-E12GFE-2 -----------------------------------------13 PAGE 5.2. CS-E18GFEW-2 CU-E18GFE-2 --------------------14 6 Wiring Connection Diagram---------------------------------15 6.1. Outdoor Unit-----------------------------------------------15 7 Electronic Circuit Diagram-----------------------------------17 7.1. Outdoor Unit-----------------------------------------------17 8 Disassembly and Assembly Instructions---------------21 8.1. Outdoor Unit-----------------------------------------------21 9 Technical Data ---------------------------------------------------23 9.1. Operation Characteristics------------------------------23 9.2. Sensible Capacity Chart--------------------------------35 10 Exploded View and Replacement Parts List -----------36 10.1. Indoor Unit -------------------------------------------------36 10.2. CU-E9GFE-2 CU-E12GFE-2-------------------------39 10.3. CU-E18GFE-2 --------------------------------------------41 © 2008 Panasonic HA Air-Conditioning (M) Sdn. Bhd. (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law. 1 Safety Precautions • Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. • Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model installed. • The caution items stated here must be followed because these important contents are related to safety. The meaning of each indication used is as below. Incorrect installation or servicing due to ignoring of the instruction will cause harm or damage, and the seriousness is classified by the following indications. This indication shows the possibility of causing death or serious injury. This indication shows the possibility of causing injury or damage to properties. • The items to be followed are classified by the symbols: This symbol denotes item that is PROHIBITTED from doing. • Carry out test run to confirm that no abnormality occurs after the servicing. Then, explain to user the operation, care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference. 1. Engage dealer or specialist for installation and servicing. If installation or servicing done by the user is defective, it will cause water leakage, electrical shock or fire. 2. Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electrical shock or fire. 3. Use the attached accessories parts and specified parts for installation and servicing. Otherwise, it will cause the set to fall, water leakage, fire or electrical shock. 4. Install at a strong and firm location which is able to withstand the set's weight. If the strength is not enough or installation is not properly done, the set will drop and cause injury. 5. For electrical work, follow the local national wiring standard, regulation and the installation instruction. An independent circuit and single outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire. 6. This equipment is strongly recommended to install with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD). Otherwise, it may cause electrical shock and fire in case equipment breakdown or insulation breakdown. 7. Use the specified cable and connect tightly for indoor/outdoor connection. Connect tightly and clamp the cable so that no external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection. 8. Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause heat-up or fire at connection point of terminal, fire or electrical shock. 9. When carrying out piping connection, take care not to let air substances other than the specified refrigerant go into refrigerat...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - CS-E18GFEW-2 (3.81 mb)
Splitgeräte - CS-E12GFEW-2 (3.81 mb)
Splitgeräte - CU-2E15GBE (3.81 mb)
Splitgeräte - CU-3E18EBE (3.81 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien