Piping Length (m) Additional Refrigerant (g/m) Gas Liquid E18GFE-1 1/2” 1/4” 7.5 15 3 20 20 If piping length is over rated length, additional refrigerant should be added as shown in the table. 14 6 Wiring Connection Diagram 6.1. Outdoor Unit 6.1.1. CU-E9GFE-2 CU-E12GFE-2 15 6.1.2. CU-E18GFE-2 16 7 Electronic Circuit Diagram 7.1. Outdoor Unit 7.1.1. CU-E9GFE-2 CU-E12GFE-2 17 7.1.2. CU-E18GFE-2 18 7.1.3. Main Printed Circuit Board CU-E9GFE-2 CU-E12GFE-2 19 7.1.4. Main Printed Circuit Board CU-E18GFE-2 20 8 Disassembly and Assembly Instructions 8.1. Outdoor Unit 8.1.1. CU-E9GFE-2 CU-E12GFE-2 1. Remove the 3 screws of the Top Panel. Fig. 13 2. Remove the 6 screws of the Front Panel. • Be save to return the wiring to its original position • There are many high voltage components within the heat sink cover so never touch the interior during operation. Wait at least two minutes after power has been turned off. 5. Remove the Control Board as follows: Fig. 14 3. Remove the screw of the Terminal Board Cover. 4. Remove the Top Cover of the Control Board by 4 hooks. Fig. 16 Fig. 17 Fig. 15 Fig. 18 21 8.1.2. CU-E18GFE-2 1. Remove the 4 screws of the Top Panel. Fig. 19 2. Remove the 10 screws of the Front Panel. Fig. 20 3. Remove the Top Cover of the Electronic Controller. • Be save to return the wiring to its original position • There are many high voltage components within the heat sink cover so never touch the interior during operation. Wait at least two minutes after power has been turned off. 4. Remove the Control Board. Fig. 22 5. Remove the 8 screws of the Electronic Controller. Fig. 23 Fig. 21 22 9 Technical Data 9.1. Operation Characteristics CS-E9GFEW-2 CU-E9GFE-2 23 24 25 26 CS-E12GFEW-2 CU-E12GFE-2 27 28 29 30 CS-E18GFEW-2 CU-E18GFE-2 31 32 33 34 9.2. Sensible Capacity Chart .. CS-E9GFEW-2 CU-E9GFE-2 220V 230V 240V Outdoor Temp. (°C) 30°C 35°C 40°C 46°C TC SHC IP TC SHC IP TC SHC IP TC SHC IP D.B. W.B. kW kW kW kW kW kW kW kW kW kW kW kW 27 17.0 2.48 2.13 0.52 2.32 2.05 0.56 2.16 1.97 0.60 1.96 1.88 0.65 19.0 2.50 0.57 19.5 2.72 2.23 0.53 2.55 2.15 0.57 2.37 2.06 0.61 2.15 1.97 0.66 22.0 2.96 2.31 0.54 2.77 2.22 0.58 2.58 2.13 0.62 2.34 2.03 0.67 .. CS-E12GFEW-2 CU-E12GFE-2 220V 230V 240V Outdoor Temp. (°C) 30°C 35°C 40°C 46°C TC SHC IP TC SHC IP TC SHC IP TC SHC IP D.B. W.B. kW kW kW kW kW kW kW kW kW kW kW kW 27 17.0 3.47 2.49 0.89 3.25 2.40 0.96 3.02 2.30 1.03 2.74 2.20 1.11 19.0 3.50 0.97 19.5 3.81 2.61 0.90 3.57 2.51 0.97 3.32 2.41 1.04 3.02 2.30 1.12 22.0 4.15 2.70 0.92 3.88 2.60 0.98 3.61 2.49 1.06 3.28 2.38 1.14 .. CS-E18GFEW-2 CU-E18GFE-2 220V 230V 240V Outdoor Temp. (°C) 30°C 35°C 40°C 46°C TC SHC IP TC SHC IP TC SHC IP TC SHC IP D.B. W.B. kW kW kW kW kW kW kW kW kW kW kW kW 27 17.0 4.96 3.26 1.44 4.64 3.14 1.54 4.32 3.01 1.65 3.92 2.87 1.78 19.0 5.00 1.56 19.5 5.45 3.41 1.45 5.10 3.28 1.56 4.74 3.15 1.67 4.31 3.01 1.80 22.0 5.92 3.53 1.47 5.55 3.40 1.58 5.16 3.26 1.70 4.69 3.11 1.83 TC -Total Cooling Capacity (kW) Indoor 27°C/19°C SHC -Sensible Heat Capacity (kW) Outdoor 35°C/24°C IP -Input Power (kW) 35 10 Exploded View and Replacement Parts List 10.1. Indoor Unit 36 REF. NO. PART NAME AND DESCRIPTION QTY. CS-E9GFEW-2 CS-E12GFEW-2 CS-E18GFEW-2 REMARKS B1 EVAPORATOR ASS'Y 1 CW1786554 < CW1800652 B1-7 FLARE NUT 1 CW1723546 < < B2 FITTING SPRING / THERMISTOR 1 CW380120 < < B3 GROUNDING TIP (W/WASHER) 1 CW113783J < < B5 FLARE NUT 1 CW119848J < CW119849J C1 TURBO FAN ASS'Y 1 CW1767414 < < C2 AIR GUIDE PLATE ASS'Y 1 CW1767421 < < C2-6 STEPPING MOTOR 1 CW151065J < < O C2-9 WIRE HARNESS ASS'Y (UPPER) 1 CW1767546 < < C3 DRAIN PAN ASS'Y 1 CW1767553 < < C3-4 STEPPING MOTOR ASS'Y 1 CW1767591 < < C3-5 SLEEVE BEARING 1 CW1767609 < < C3-6 SHAFT (DAMPER) 1 CW1767616 < < C3-7 WIRE HARNESS ASS'Y (LOWER) 1 CW1767623 < < C4 LOCK NUT/ FAN BLADE 1 CW847002J < < C5 AIR FILTER 1 CW1767647 < < E1 SWITCH BOX 1 CW1767654 < < E2 INDICATION LAMP COVER 1 CW1786561 < < E3 MOUNTING PLATE, PRINTED CIRCUIT 1 CW1767678 < < E4 SHIELD PLATE 1 CW1767685 < < E5 SHIELD PLATE 1 CW1767692 < < E6 SHIELD PLATE 1 CW1767700 < < E7 SWITCH KNOB 1 CW0728803 < < E8 PRINTED CIRCUIT ASS'Y (CONTROL) 1 CW1786617 CW1786624 CW1786631 O E8-1 FUSE 1 CW153875J < < E8-3 THERMISTOR (FOR COIL) 1 CW129970J < < E9 WIRE HARNESS ASS'Y 1 CW1786648 < < E10 PRINTED CIRCUIT ASS'Y (SERVICE) 1 CW1786794 < < E11 TERMINAL BLOCK 1 CW1786662 < < E12 WIRE CLAMP 1 CW0812847 < < E13 PRINTED CIRCUIT ASS'Y (DISPLAY) 1 CW1786655 < < E14 PRINTED CIRCUIT ASS'Y (SENSOR) 1 CW1767755 < < E15 EARTH WIRE 1 CW1786679 < < E17 SHIELD PLATE ASS'Y 1 CW1767786 < < E17-1 INSULATION SHEET 1 CW1767793 < < E18 DC FAN MOTOR 1 CW1889408 < < O E19 PAN HEAD TAPPING SCREW 2 CW111403J < < E20 EARTH PLATE 1 CW1786686 < < E21 WASHER (FOR EARTH) 2 CW1786749 < < F1 BOTTOM FRAME ASS'Y 1 CW1767818 < < F1-3 THERMAL INSULATION ASS'Y 1 CW1786756 < < F1-4 THERMAL INSULATION ASS'Y 1 CW1786763 < < F2 BELL MOUTH ASS'Y 1 CW1767849 < < F3 COVER, MOTOR 1 CW1767856 <...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - CS-E18GFEW-2 (3.81 mb)
Splitgeräte - CS-E12GFEW-2 (3.81 mb)
Splitgeräte - CS-E9GFEW-2 (3.81 mb)
Splitgeräte - CU-2E15GBE (3.81 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien