7 InstallAdditionalMassStorageDevicesInstallingaSCSITapeDrive
1. Set the jumpers on the device to an unused address. Refer to the Technical
NOTE
If you are installing an IDE drive or internal
Reference Label, inside the NetServer, and to the SCSI addressing example,
SCSI devices with certain configurations, you
below, for more information. Verify that termination power is off.
may need additional cables or adapters. For
part numbers for HP cables, adapters, and
2. Remove the tray from one of the front shelves and store it.
trays, and configuration information, see the
3. Install the tape drive, using the rails supplied with the device.
Technical Reference Label on the side of the
chassis or the Management Software CD-ROM.
4. Connect the tape drive to SCSI cable and power cable.
5. Remove the shelf cover plate from inside the front bezel before replacing the
Preinstalled Devices
cover. See figure below.
! A flexible disk drive is preinstalled in Shelf 1
Installing Additional SCSI Hard Disk Drives
! An IDE CD-ROM drive is preinstalled in Shelf 2
1. Set the jumpers on the device to an unused address. Refer to the Technical
! A SCSI hard disk drive is preinstalled in Shelf 5 in the
Reference Label on the side of the NetServer chassis and the SCSI
NetServer Model 2100 (SCSI ID=0)
Addressing section below for more information.
Boot device priority order
2. Install the drive.
The system searches for a bootable device in the following order:
Rear Shelf 6: Remove the rear shelf cover plate and install the drive using the
1. IDE CD-ROM drive with bootable CD-ROM
four 1/4" screws supplied with the device. Replace the shelf cover plate when
the device is in place.
2. Flexible disk drive with bootable flexible disk
Front Shelves: Use the mass storage trays supplied with your NetServer.
3. IDE hard disk drive (if user-installed)
3. Connect the hard disk drive to SCSI cable and power cable.
4. PCI Slots in the following order: 3, 1, 2, 4
Installing an Additional IDE Device
! If you are installing an additional IDE device,such as an IDE CD-ROM drive or
IDE hard disk drive, refer to the Accessories chapter in your HP NetServer
User Guide.
! You may need to remove the filler panel from inside the front bezel before
replacing the cover. See figure below.
Technical
Reference
Label

Front Cover
All front shelf hard disk drives
must be installed in the mass

Shelf 5
storage trays provided
(SCSI hard
disk drive)

Shelf 1
Filler panel
(3.5" flexible
Shelf 6
disk drive)
Shelf 2
(CD-ROM drive)

Shelf 3
4x
Shelf 4
Front view
Rear view
(mass storage
tray installed)

SCSI Termination
A2
A1
A0
TE
Example of a hard disk drive and jumper settings.
The NetServer SCSI cable is terminated. Verify added devices
A0, A1 and A2 are SCSI ID settings and TE is device
are not actively terminated.
0
active termination setting (always off).
SCSI Addressing
1
Each SCSI device must have a different SCSI address or ID.
This address (0 through 6) dictates where each SCSI device is
2
in the boot priority order and is set by means of jumpers located
on the outside of the device.
SCSI ID
3
The figure and table to the right are an example of a SCSI hard
4
disk drive that may be preinstalled in your HP NetServer Model
2100. Use this as a general reference for jumper locations and
JUMPERS
5
settings. Refer to the documentation that came with your SCSI
device for the correct jumper locations and settings. Refer to the
A2
A1
A0
TE
6
Technical Reference Label on the side of the NetServer chassis
for recommended SCSI setting strategy.
7
reserved
8 ConfiguretheHPNetServer
1. Replace the air cooling duct and cover. Refer to the diagram in
6. Choose automatic mode for first-time installation of NetWare 4.1 or
Roadmap Step 4 showing proper alignment of the cover.
Windows NT Server 3.51 on a factory-configured HP NetServer E 40.
Connect all external power and data cords.
Choose manual mode to install an alternative NOS, to customize your
2. Turn on the HP NetServer and monitor and insert the HP
hard drive partition or if you replaced HP components (for example,
NetServer Navigator CD-ROM into the CD-ROM drive. If the
replaced an HP board with a third-party NIC or SCSI controller board.
NetServer doesn't boot from the Navigator CD-ROM, turn the
7. If you are installing non-Plug-and-Play ISA boards, Configuration
power off, wait 10 seconds, and turn the power on again. If the
Assistant will instruct you when to install them. During installation, the
system fails to boot, follow the instructions on the screen:
HP NetServer may reboot several times. If the system fails to boot,
! Press F2 to enter Setup
follow the instructions on the screen to correct the problem.
! Press F4 to accept automatic configuration update
8. Install your NOS. If you selected HP automated installation process,
3. Go to the HP NetServer Navigator Main Menu and click on the
you will be guided through the process by a series of HP screens.
“Configuration Assistant” icon.
If you selected NOS vendor installation process, view and print the HP
4. Click the "Express" button to begin the configuration process .
NOS installation tips. Install the NOS using the installation utility
5. Select your NOS. If you choose Novell NetWare 4.1 or Windows
supplied with your NOS.
NTAS 3.51, you will be prompted to choose between automatic
9. Install Server Management Software.
or manual NOS install.


...