Energize brewer and pour one decanter (64 oz.) of cold water into pour-over opening. When READY TO BREW light comes on, read temperature displayed on thermometer. Adjust thermostat by turning shaft; clockwise increases temperature. 1/8 turn = approximately 10.F. Refer to Table 1 below for proper brewing temperature based on altitude. Upon completion, remove thermometer and reinstall vent tube. THERMOSTAT DIAL-TYPE THERMOMETER IN VENT HOLE TANK LID ASSEMBLY ADJUSTING SHAFT Fig. 10 Checking and Adjusting Brew Temperature Table 1 Boiling Temperature by Altitude ELEVATION (feet above seal level) 05001,0001,5002,0002,5003,0003,5004,0004,5005,0005,5006,0006,500 TEMP. (. F) 195 200 205 210 190 IDEAL BREWING TEMPERATURE MAXIMUM SAFE TEMPERATURE SETTING BOILING POINT OF WATER SERVICING INSTRUCTIONS (continued) SERVICING INSTRUCTIONS (continued) TIMER ADJUSTMENT The amount of water dispensed automatically during a brew cycle is controlled by the timer. Place empty decanter under brew chamber. Press BREW button. Brewer should dispense one decanter of water. To adjust amount: Remove brew chamber and button plug. Adjust knob on timer; clockwise increases time. Run several cycles to check amount of water delivered. Replace button plug. REMOVE TANK LID ASSEMBLY Unplug brewer or turn circuit breaker OFF. Turn OFF water supply. Remove top panel. Pull vent tube and inlet elbow out of basin pan. Pull water inlet tube out of basin pan. Remove basin pan. On models with faucet, disconnect inlet pipe at faucet shut-off valve and outlet pipe at faucet. Disconnect all wiring from thermostat, hi-limit, and heating element. Loosen center screw on tank hold-down bracket. Remove hold-down bracket by sliding short slotted end off of locking stud and lifting it off. Remove cover assembly by lifting it straight up. Reassemble in reverse order. REPLACE THERMOSTAT Unplug brewer or turn circuit breaker OFF. Turn OFF water supply. Remove top panel. Disconnect all wiring from thermostat only. Loosen and free jam nut from pass-thru fitting securing temperature sensing bulb. Remove two screws holding thermostat to bracket. Lift out thermostat, sensing bulb and thermostat gasket. Reassemble in reverse order. REPLACE HEATING ELEMENT Remove tank lid assembly per above. Remove two hex nuts holding element to cover. Pull element from mounting holes. Reassemble in reverse order. IMPORTANT: Water pressuremust be between 20 p.s.i and 90 p.s.i. flowing pressure. If water pressure exceeds this value, or if water pressure varies greatly, a pressure regulator must be installed in the water supply line. IMPORTANT: Before setting assembly into tank, make sure tank lid gasket is properly seated on flange of lid. DO NOT OVER-TIGHTEN. IMPORTANT: When mountingthermostat, be sure a new seal washer is placed below the fitting on the capillary line. Push sensing bulb thru tank lid until fitting seats. Tighten capillary lock nut only enough to ensure no water leakage. Excessive tightening is not necessary. IMPORTANT: When replacing heating element, also replace seal gaskets. 13 SERVICING INSTRUCTIONS (continued) SERVICING INSTRUCTIONS (continued) Fig. 11 Clean Strainer Screen REPLACE SOLENOID Symptom: Automatic brewer will not flow water; or, automatic brewer drips continuously from brew head. Unplug power cord or turn circuit breaker OFF. Turn OFF and disconnect water supply from brewer inlet fitting. A. (OLD-STYLE) Remove hex nut holding inlet fitting into back of brewer. Remove two screws holding access door in place. Remove access door. Remove front panel. On faucet models, remove flare connection from “tee” inlet fitting. Push solenoid forward slightly and lift to release it from bracket. Disconnect wiring and remove rubber tubing from solenoid. Remove fittings from old solenoid and transfer to new solenoid. If necessary, replace flow control at this time. B. (NEW-STYLE) Unscrew water inlet fitting from solenoid. Remove two screws holding access door in place. Remove two screws holding solenoid to door. Remove brew water tube from solenoid. On faucet models, remove faucet water tube from bypass side of solenoid by pressing the white ring portion of the tube fitting tightly against the metal portion while pulling the tube off of the solenoid. Disconnect wiring from solenoid. Transfer solenoid bracket to new solenoid. Reassemble in reverse order. CLEAN SOLENOID SCREEN (NEW-STYLE) Symptom: Automatic brewer will not flow water. Unplug power cord or turn circuit breaker OFF. Turn OFF and disconnect water supply from brewer inlet fitting. Unscrew water inlet fitting from solenoid. Using needle-nose pliers, withdraw strainer screen from solenoid. Clean screen under faucet. A stiff bristle brush may be used if necessary. Reinsert screen in solenoid. Be careful to maintain correct orientation. (The OPEN END of the screen goes in FIRST.) Reassemble in reverse order. 14 SERVICING INSTRUCTIONS (continued) SERVICING INSTRUCTIONS (continued) REPLACE TIMER ASSEMBLY Unplug powe...

Dieses Handbuch ist für folgende Modelle:
Kaffeemaschinen - 8540 (1.66 mb)
Kaffeemaschinen - 8541 (1.66 mb)
Kaffeemaschinen - 8542 (1.66 mb)
Kaffeemaschinen - 8543 (1.66 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien