Login:
Stimmen - 4, Durchschnittliche Bewertung: 3.8 ( )

Anleitung Cecilware, modell C-2003LG-IT

Hersteller: Cecilware
Dateigröße: 800.39 kb
Dateiname: bfa95de9-44ac-40cd-b7f0-adc609ea1c89.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


C-2003G-IT C-2003RG-IT C-2003LG-IT Volts 120 120 120 Watts 1,800 1,800 1,800 Amps 15 15 15 Wall Outlet (Receptacle) 5-15R 5-15R 5-15R All Brew Centers are single phase with 2 wires plus a ground with cord and plug, except Eport 220V, 1 PH, 50 cycles (UROPEAN). MECHANICAL SPECIFICATIONS MODEL NO. C-2003G-IT C-2003RG-IT C-2003LG-IT Tank Capacity (US gal.) Cups/Brew Cycle 12 12 12 Cups/Hour 120 120 120 Height (includes 2 ." legs) 31 31 31 Width 8 16 16 Depth (+2”for ."water connection) 17 . 17 . 17 . Ship Weight lbs. 40 50 50 START-UP PROCEDURE 1. PLUG THE POWER CORD INTO A PROPER RECEPTACLE. 2. ACTIVATE THE POWER SWITCH ON (Toggle Up), located in the lower left corner in back of Brewer. 3. PUSH THE POWER BUTTON (RED) ON THE TOUCHPAD ON THE FRONT PANEL. The power switch controls all power including the Heater Elements in the tank and the Warmers. The Brewer will automatically start filling the tank, then it will start to heat up the water in the tank, until it reaches the proper preset temperature (200°F) (About 20 minutes). The LCD window will display a series of messages: CECILWARE shows day FILLING shows day HEATING shows day READY shows day NG39A shows time TANK shows time shows temp shows time TO BREW shows time 4. PLACE PAPER FILTER AND COFFEE IN THE FUNNEL, AND INSERT FUNNEL IN THE BREWER. 5. PUSH THE BREW BUTTON. YOU NEED NOT WAIT FOR THESE MESSAGES TO COME UP FIRST. After the brew button is pressed, when the “READY TO BREW” message comes on, the Brewer automatically begins brewing coffee. The LEDs will light up and stay on during the brewing cycle. NOTE: THE BREWER CAN BE PROGRAMMED TO START ITSELF UP AT ANY DESIRED TIME AND SHUT ITSELF OFF AT ANY DESIRED TIME, PROVIDED THAT THE MAIN POWER SWITCH IN THE BACK OF THE BREWER IS KEEPT ON (Toggle Up). RECOMMENDED COFFEE AMOUNT FOR BREWING 2.5 oz. for one (1) decanter, . US gal. (12 cups) 2 FEATURES AND BENEFITS OF THE DIGITAL, MEMBRANE CONTROL TOUCH PAD BREWER 1. 100% Solid State Control for improved reliability. 2. Modular design and reduced component count for ease of service. 3. Optional Low Water Temperature Lockout to prevent dispensing at water temperatures below an adjustable threshold. 4. Redundant system interlocks for uncompromising user safety. 5. Large two line display for viewing system status on digital display and modifying parameters. 6. Individual brew cycle counters and totalizers for product marketing information and inventory control. 7. Advanced system diagnostics that continuously monitor the status of valves, sensors, and heaters to ensure proper operation and aid in identifying potential problems. 8. Protection from heater burnout due to low water level in the reservoir tank. 9. Stable water temperature regulation with adjustment to one-degree Fahrenheit. 10. Units of measure displayed in either English or Metric. 11. Digital adjustment of brewing size in ounce. 12. Audible alarms: a) When brew cycle is ready b) Warmers Warning “time to brew new batch of coffee”. 13. Optional power saving “sleep mode” for extended periods of inactivity (self turn off and on, as programmed). 3 INSTALLATION AND OPERATING INSTRUCTIONS Warranty is void if the Brewer is connected to any Voltage other than the Voltage specified on the data label of the Brewer. UNPACKING AND INSPECTION Carefully unpack the Brewer by cutting the straps and lifting the carton off the Brewer. ASSEMBLY AND SET-UP The Brewer is shipped complete with: DESCRIPTION C-2003G-IT C-2003RG-IT C-2003LG-IT Decanters 3 3 3 Funnels with sample Filter pack 1 1 1 WATER HOOK UP The National Sanitation Foundation (NSF) requires the following for NSF approved installation: 1. A quick disconnect water connection or enough extra coiled tubing (at least 2x the depth of the unit) so that the Brewer can be moved for cleaning underneath. 2. An approved flow-back prevention device such as a double check valve to be installed between Brewer and water supply. WATER CONNECTION The Brewer comes equipped with a . inch flare water inlet fitting located in the back. Use a . inch copper tubing to connect the Brewer to a cold water supply. Water pressure should be: 20 PSI min. to 90 PSI max. An external shut-off valve and a water filtering system with a charcoal filter are highly recommended. Turn water supply on and check for leaks at the water inlet connections, tighten flare fitting if necessary. ELECTRICAL CONNECTIONS For standard connections, Plug Power cord into a proper electrical outlet 15A. 4 5 NG34A-E CAUTION HOT WATER D:\1-Milt\Labels & Logos\Techno copy.tif PROGRAMMING INSTRUCTIONS The following is a Functional Description of the Single Station Brewer: Modes of Operation - Overview Initialization Mode – This mode is only active during the first few seconds after a “power-on” or system reset. The main function of this mode is to perform some special self-testing functions and configure the system using the previously saved operating parameters. Normal Mode – This mode becomes active immediately afte...

Dieses Handbuch ist für folgende Modelle:
Kaffeemaschinen - C-2003G-IT (800.39 kb)
Kaffeemaschinen - C-2003RG-IT (800.39 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien