|
Anleitung Zusammenfassung
(305 mm) vent section (77L71) 86L97 SV4.5HTS Horizontal Square Termination with Firestop/Spacer (96K80) and Adapter (74L61) 94L10 SV4.5HTSS Horizontal Short Square Termination with Firestop/Spacer (96K80) and Adapter (74L61) H2152 SV4.5CGV-1 Vertical Termination Figure 58 COLD CLIMATE INSULATION If you live in a cold climate, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level. A hearth extension is not required with this appliance. If a hearth extension is used, do not block the lower control compartment door. Any hearth extension used is for appearance only and does not have to conform to standard hearth extension installation requirements. Note: Combustible wall finish materials and/or surround materials must not be allowed to encroach the area defined by the appliance front face (black sheet metal). Never allow combustible materials to be positioned in front of or overlapping the appliance front face. See Figures 55 and 56 on page 23. Non-combustible materials, such as surrounds and other appliance trim, may be installed on the appliance front face with these exceptions: they must not cover any portion of the glass or louvers; they may cover any portion of the top radiant panel or the air gaps surrounding the top radiant panel up to the installed hood. Vertical installation clearances to combustible mantels vary according to the depth of the mantel. (See Figure 58 ). Mantels constructed of noncombustible materials may be installed at any height above the appliance opening; however, do not allow anything to hang below the hood. INSTALLATION ACCESSORIES 17" 14" Min. Distance To Unprotected Side Wall 8 ..." 45° Combustible Materials Allowed In Shaded Area “Safe Zone” 12" 5" Min. Distance To Protected Side Wall Top View Of Fireplace Side Wall Side Wall Combustible materials may project beyond the sides of the fireplace opening as long as they are kept within the shaded areas illustrated in Figure 57. Figure 57 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 25 *All compressed flex vents can be expanded up to two times. INSTALLATION ACCESSORIES (Continued) Listed Secure Flex™Components Cat. No. Model No. Description These termination kits include firestop/spacer, gear clamps and flex adapter. 94L09 SF-HTSS Horizontal Short Small Square Termination without Flex 4 0 L 4 9 - S 2 1 T I K F SS Flex Short Small Square Term. with 12 in. (305 mm of *compressed Flex 5 0 L 4 9 - S 8 1 T I K F SS Flex Short Small Square Term. with 18 in. (457 mm) of *compressed Flex 6 0 L 4 9 - S 4 2 T I K F SS Flex Short Small Square Term. with 24 in. (610 mm) of *compressed Flex 7 0 L 4 9 - S 6 3 T I K F SS Flex Short Small Square Term. with 36 in. (914 mm) of *compressed Flex 8 0 L 4 9 - S 8 4 T I K F SS Flex Short Small Square Term. with 48 in. (1219 mm ) of *compressed Flex These termination kits include firestop/spacer, gear clamps and flex adapter. 86L96 SF-HTS Horizontal Square Termination without Flex 77L87 SFKIT12S Flex Square Term. with 12 in. (305 mm of *compressed Flex 77L88 SFKIT18S Flex Square Term. with 18 in. (457 mm) of *compressed Flex 77L89 SFKIT24S Flex Square Term. with 24 in. (610 mm) of *compressed Flex 77L90 SFKIT36S Flex Square Term. with 36 in. (914 mm) of *compressed Flex 77L91 SFKIT48S Flex Square Term. with 48 in. (1219 mm ) of *compressed Flex 56L74 SFVT30 Vertical Termin. for Flex (flat to 6/12) with Flex Adapter, section of rigid vent, roof support collar assembly, roof flashing and storm collar. 56L75 SFVT45 Vertical Termin. for Flex (6/12 to 12/12) with Flex Adapt...
Dieses Handbuch ist für folgende Modelle:Kamine - DT-400CEP (973.7 kb)
Kamine - DT-400CEN (973.7 kb)
Kamine - DT-400CEP (973.7 kb)
Kamine - DR-400CEN (973.7 kb)