Login:
Stimmen - 1, Durchschnittliche Bewertung: 4 ( )

Anleitung Empire Comfort Systems, modell BVD36FP52

Hersteller: Empire Comfort Systems
Dateigröße: 4.27 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


b. Debris around throat of main burner. —Inspect the opening at the base of the main burner. It is imperative that NO material be placed in this opening. Page 20 19400-3-0406 STANDING PILOT PROPANE/LP GAS CONVERSION "B-VENT" FIREPLACES Model Conversion Kit Model (Part Number) BVD34FP3 SERIES BVCK34P (19160) BVD36FP3 SERIES BVCK36P (19161) BVP42FP3 SERIES BVCK42P (19162) FOR CONVERSION TO LIQUEFIED PETROLEUM GAS WARNING This conversion kit is to be installed by an Empire Comfort Systems, Inc. dealer (or other qualified agency1)* in accordance with the manufacturer's instructions and all codes and requirements of the authority having jurisdiction. Failure to follow instructions could result in serious injury or property damage. The qualified agency performing this work assumes responsibility for this conversion. 1 National Fuel Gas Code Z223.1 (Latest Edition), Natural Gas and Propane Installation Code, CSA B149.1 *The term "qualified agency" means any individual, firm, corporation or company which either in person or through a representative is engaged in and is responsible for (a) the installation of gas piping or (b) the connection, installation repair, or servicing of equipment, who is experienced in such work, familiar with all precautions required, and has complied with all the requirements of the authority having jurisdiction. PARTS LIST Conversion Kit Model BVCK34P BVCK36P BVCK42P Part Description Kit No. 19160 Kit No. 19161 Kit No. 19162 Quantity Supplied Fireplace BVD34FP3 SERIES BVD36FP3 SERIES BVP42FP3 SERIES Pilot Orifice #35 (R-7658) #35 (R-7658) #35 (R-7658) 1 Main Burner Orifice P-289 1.35mm P-208 1.45mm P-250 1.65mm 1 Dexen 10" w.c. Regulator R-7548 R-7548 R-7548 1 Gas Conversion Label 2139 2139 2139 1 PILOT VENTIN CHECK SAFETY SHUTDOWN PERFORMANCE WARNING Perform the safety shutdown test any time work is done on a gas system to avoid the possibility of fire or explosion with property damage, personal injury or loss of life. SAFETY SHUTDOWN SYSTEM Continuous Ignition Systems 1. Place gas control knob in Pilot position. Main burner should go off and pilot should remain lit. 2. Extinguish pilot flame. Pilot gas flow should stop within 3 minutes. Safety shutoff of pilot gas proves complete shutdown since safety shutoff valve blocks flow of gas to main burner and pilot. 3. Wait 5 minutes, then relight pilot burner and operate system through one complete cycle to make sure all controls operate properly. Gas input for "B-Vent" fireplace converted to Liquefied Petroleum Gas: BVD34FP3 SERIES 21,000 BTU per hour BVD36FP3 SERIES 25,000 BTU per hour BVP42FP3 SERIES 30,000 BTU per hour The "B-Vent" fireplace when converted to LP Gas will have manifold pressure of 10.0" w.c. at the valve outlet with the inlet pressure to the valve from a minimum of 10.8" w.c., for the purpose of input adjustment, to a maximum of 14.0" w.c. INSTRUCTIONS FOR CONVERSION 1. If the fireplace is installed, turn off gas and electric supply before making the gas conversion. 2. Identify the fireplace model to be converted, and read all instruction steps prior to converting the gas valve. 3. Remove all logs from the burner assembly. 4. Open the sliding valve access door. 5. Depress and turn the gas cock dial to the "OFF" position. VALVE CONVERSION 6. Remove two (2) screws, regulator, and gasket from gas valve control body. 7. Install the new gasket, regulator, and gasket from gas valve control body. BURNER ORIFICE CONVERSION - Tube style burners 8a. On models BVD(34,36)FP3 series fireplaces, you will have a U-shaped burner tube. To gain access to the main orifice, simply bend over the small retainer tab located at the front right end of the tube using pliers. 9a. Remove the 1/4" long screw from the air shutter at the left end of the tube. 10a. Pull up on the back of the burner and rotate forward to gain access to the main orifice. Remove the orifice and replace with the LP orifice designated in the orifice reference chart. Secure the new orifice. 11a. Pivot the burner tube back down in its original position mating with the air shutter, and reinstall the 1/4" long screw. Set the air shutter opening in accordance with the dimension shown in the reference chart for the appropriate model fireplace. 19400-3-0406 Page 21 BURNER ORIFICE CONVERSION - Slope style burners 8b. On model BVP42FP3 series fireplaces, you will have a rectangular slope style burner. To gain access to the main orifice, disconnect the gas supply tubing at the air shutter. 9b. Remove the orifice holder from the air shutter, then remove the NG orifice. 10b. Replace the removed NG orifice with the new LP orifice designated in the orifice reference chart for your fireplace model. Secure the new orifice and replace the orifice/orifice holder back into the air shutter and secure. 11b. Loosen the air shutter screw and reset the air shutter opening in accordance with the dimension shown in the reference chart for the appropriate model fireplace. PILOT ORIFICE CONVERSION 12. ...

Dieses Handbuch ist für folgende Modelle:
Kamine - BVD34FP30 (4.27 mb)
Kamine - BVD34FP50 (4.27 mb)
Kamine - L)N-1 (4.27 mb)
Kamine - BVD36FP32 (4.27 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien