|
Anleitung Zusammenfassung
HANDLE ONLY WHEN LOGS ARE COOL. TURN OFF ALL ELECTRICITY TO THE APPLIANCE BEFORE YOU INSTALL GRATE AND LOGS. WARNING: THIS APPLIANCE IS NOT MEANT TO BURN WOOD. ANY ATTEMPT TO DO SO COULD CAUSE IRREPARABLE DAMAGE TO YOUR APPLIANCE AND PROVE HAZARDOUS TO YOUR SAFETY. WARNING: THE SIZE AND POSITION OF THE LOG SET WAS ENGINEERED TO GIVE YOUR APPLIANCE A SAFE, RELIABLE AND ATTRACTIVE FLAME PATTERN. ANY ATTEMPT TO USE A DIFFERENT LOG SET IN THE FIREPLACE WILL VOID THE WARRANTY AND WILL RESULT IN INCOMPLETE COMBUSTION, SOOTING, AND POOR FLAME QUALITY. Glowing Embers (Rockwool) Placement Refer to the detailed glowing embers placement instructions provided in the LOG PLACEMENT GUIDE accompanying this document. Ceramic Panel Placement Refer to the detailed ceramic panel placement instructions provided in the LOG PLACEMENT GUIDE accompanying this document. Millivolt Appliance Checkout The pilot flame should be steady, not lifting or floating. Flame should be blue in color with traces of orange at the outer edge. The top ..." (10 mm) at the pilot generator (thermopile) and the top ..." min (tip) of the quick drop out thermocouple should be engulfed in the pilot flame. The flame should project 1" (25 mm) beyond the hood at all three ports. See Figure 9. To light the burner, refer to the lighting instructions on pages 11 and 12. Figure 9 Electronic Appliance Checkout To light the burner, refer to the lighting instructions onpage 13 and 14. Ensure the ignitor lights the pilot. The pilot flame should engulf the flame sensor as shown in Figure 10. MILLIVOLT Thermocouple Hood Ignitor Rod ..." Min (9 mm) Thermopile Pilot Nozzels Figure 10 With proper care and maintenance, your appliance will provide many years of enjoyment. If you should experience any problem, first refer to the trouble shooting guide in this manual. If problem persists, contact your Lennox distributor. ELECTRONIC Proper FlameAdjustment Pilot Nozzle 3/8 To 1/2 Inch (9 mm to 13 mm) Ground Electrode Flame Rod Hot Surface Igniter ACCESSORY COMPONENTS Remote Control System (Standard) H0249 RCL Standard Remote Control System The Model RCL (Standard) Remote Control System, features a simple On/Off control function for the fireplace. This model includes a hand-held transmitter, a remote receiver with wall-mount coverplate and all hardware required to install the unit. The remote receiver can be wall or hearth mounted. Flame Modulating Remote Control – Natural Gas H0301 RCL-MN Flame Modulating Remote Control – LP/Propane Gas H0302 RCL-ML Flame Modulating Remote Control Flame Modulating Remote Controls were developed to provide a safe, reliable and user- friendly remote control system for appliances equipped with a Millivolt Gas Valve. A detailed set of instructions are included with each remote. Remote Control System (Deluxe) H0251 RCL-T Deluxe Remote Control System The Model RCL-T (Deluxe) Remote Control System has all of the features of the standard system along with an added easy to read LCD screen which presents access to many enhancements, including; battery power level indicator, timer, mode of operation, thermostatic display including room temperature in either metric of English units, flame indicator and clock. Fully programmable, the Model RCL-T allows for command over nearly all operational and temperature variables, using the hand held remote control transmitter. The kits attach to the glass enclosure panel without the use of hardware. The decorative arch kits can not be used in conjunction with the screen panel kit. Arch Door Kits Model No. Catalog No. Model No. Polished Brass Brushed Stainless EDV3530 81L34 ADK35CPB 98L68 ADK35CBS EDV4035 81L35 ADK40CPB 98L69 ADK40CBS EDV4540 81L36 ADK45CPB 98L70 ADK45CBS NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. ACCESSORY COMPONENTS CONTINUED (FBK-200 Models Only) Forced Air Blower Kits -Single Speed -Variable Speed with wall-mountable switch -Variable Speed with unit-mountable switch 80L84 80L85 80L86 FBK-100 FBK-200 FBK-250 Forced Air Kit The FBK-100 blower provides constant velocity forced air circulation. The FBK-200 assembly with variable speed, wall-mountable switch provides variable speed forced air circulation. The FBK-250 assembly with variable speed unit-mountable switch, also provides variable speed forced air circulation. Assembled Louver Kits Model No. Catalog No. Model No. Polished Brass Brushed Stainless EDV3530 88L28 LVR35PB-2 88L32 LVR35BS EDV4035 88L29 LVR40PB-2 88L33 LVR40BS EDV4540 88L30 LVR45PB-2 88L34 LVR45BS These louvers are designed to replace the standard charcoal louvers that are provided with the appliance. The brass and brushed stainless louver kits include six (6) louvers. Clean Face Panel Kits Model No. Catalog No. Model No. EDV3530 88L36 RAD35C-2 EDV4035 88L37 RAD40C-2 EDV4540 88L38 RAD45C-2 Clean faced panel kits are available to convert the standard louvered fireplaces to radiant models which are more suited for finishing around the firebox opening with non-combustible materials, su...
Dieses Handbuch ist für folgende Modelle:Kamine - B-ENC0454VDE (3.72 mb)
Kamine - B-ENC5304VDE (3.72 mb)
Kamine - B-MNC0353VDE (3.72 mb)
Kamine - B-MNC0454VDE (3.72 mb)